Allen Bradley PLC 1734-OB8E / 1734OB8E

China Allen Bradley PLC 1734-OB8E / 1734OB8E supplier
Allen Bradley PLC 1734-OB8E / 1734OB8E supplier Allen Bradley PLC 1734-OB8E / 1734OB8E supplier Allen Bradley PLC 1734-OB8E / 1734OB8E supplier Allen Bradley PLC 1734-OB8E / 1734OB8E supplier Allen Bradley PLC 1734-OB8E / 1734OB8E supplier Allen Bradley PLC 1734-OB8E / 1734OB8E supplier Allen Bradley PLC 1734-OB8E / 1734OB8E supplier Allen Bradley PLC 1734-OB8E / 1734OB8E supplier

Large Image :  Allen Bradley PLC 1734-OB8E / 1734OB8E

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley POINT I/O 1734-OB8E / 1734OB8E

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $75.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 30 PCS
Detailed Product Description

1734-OB8E technical data PDF download POINT I/O 1734-OB8E / 1734OB8E 8-Point 24V DC Protected Source Output

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O Digital Output

The 1734-OB8E is the protected eight-point 24V DC sourcing output. Eight channels, one byte of output data, 1.0 A per channel with a 3.0 A module limit, and a red fault LED for every channel in addition to the yellow status LED.

That LED pair is the whole distinction from 1734-OB8: same voltage window, same current ratings, same 2.0 W dissipation at 28.8V DC, but a fault is reported where it happens instead of only at module level.

1734-OB2E 2 protected sourcing outputs, red fault LED per channel, 2.0 A per module IN STOCK
1734-OB4E 4 protected sourcing outputs, red fault LED per channel, 3.0 A per module IN STOCK
1734-OB8E 8 protected sourcing outputs, red fault LED per channel, 3.0 A per module IN STOCK

Product Specifications 1734-OB8E (PDF)
 Number of outputs
 8 (1 group of 8), non-isolated, sourcing
 Output current rating, per output
 1.0 A
 Output current rating, max, per module
 3.0 A
 External DC supply current
 32 mA
 On-state voltage, min
 10V DC
 On-state voltage, nominal
 24V DC
 On-state voltage, max
 28.8V DC
 On-state voltage drop, max
 0.2V DC
 On-state current, min per channel
 1.0 mA
 Off-state leakage, max
 0.5 mA @ 28.8V DC
 Surge current
 2 A for 10 ms, repeatable every 3 s
 POINTBus current, max
 75 mA @ 5V DC
 Isolation voltage
 50V (continuous), reinforced insulation type, tested 2500V DC for 60 s, field side to system
 External DC supply, nominal
 24V DC
 External DC supply range
 10...28.8V DC
 Terminal base screw torque
 0.8 Nm (7 lb-in)
 Dimensions, HxWxD
 56.6 x 12.1 x 77.5 mm
 Wiring category
 2 - on signal ports
 Operating temperature
 -20...55 °C
 Enclosure
 None (open style)
 Power dissipation, max @ 28.8V DC
 2.0 W @ 28.8V DC
 Thermal dissipation, max @ 28.8V DC
 6.8 BTU/hr @ 28.8V DC
 Weight, approx
 35.4 g
 Module location
 1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS
 Field wiring terminations
 0...7 - Outputs 0...7, common daisy-chained from the adapter, 1734-FPD or 1734-EP24DC
 Indicators
 8 yellow output status, 8 red output fault, 2 green/red module and network status

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN056-EN-E (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-OB8E original product photograph, wide view 1734-OB8E original product photograph, label view 1734-OB8E original product photograph, second unit

Sixteen field-side LEDs on one slice

Eight yellow status plus eight red fault LEDs, all logic-driven and field side, plus the two green/red module and network indicators. Commissioning an eight-valve bank is a matter of forcing each channel and watching which LED answers, and a later fault shows the same way without a laptop.

Load and current limits

Per output 1.0 A, per module 3.0 A - eight channels therefore cannot all run at full rating. The practical pattern is eight pilot valves at 0.3 to 0.5 A, which totals 2.4 to 4.0 A; the 4.0 A case already exceeds the module limit, so measure the real coil current or split the bank across two slices.

Heat and cabinet sizing

The slice dissipates 2.0 W (6.8 BTU/hr) at 28.8V DC before load current, and the load current heat appears in the driven devices rather than in the module. In a sealed enclosure sized by temperature rise, that is the number to add to the rest of the slice budget.

Wiring and supply

Outputs 0 to 7 are terminals 0 to 7. Common must be daisy-chained from a POINT I/O adapter, 1734-FPD or 1734-EP24DC, or from a user-supplied auxiliary terminal block; the 24V DC for the module comes from the same source through the internal power bus and draws 32 mA.

Choosing between OB8, OB8E and OB2EP

1734-OB8 is the plain eight-point output; 1734-OB8E adds per-channel protection and fault indication; 1734-OB2EP is the protected two-point module with a different fault behaviour and its own installation instructions. All three sit in the same 10...28.8V DC window with 50V isolation, so the selection is about diagnostics granularity.

FAQ — 1734-OB8E

What does the extra red LED on a protected output give me?

One red output-fault indicator per channel, driven from the logic side. When a channel trips on short circuit or thermal overload its yellow status LED goes off and its red fault LED comes on, so the electrician knows which of the eight loads to look at without pulling the module.

Does a protected module limit current or latch off?

The module limits the channel current and reports the fault; the published rating is 1.0 A per output with a module maximum of 2.0 A for 1734-OB2E and 3.0 A for 1734-OB4E and 1734-OB8E. Clearing the fault is by removing the cause and re-energising the channel - there is no manual reset button.

What is the difference between 1734-OB8 and 1734-OB8E?

The output stage, voltage window and current ratings are identical; the difference is per-channel electronic protection with a dedicated fault indicator instead of module-level reporting only. Both use the same 1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS base.

Are the outputs isolated from the backplane?

Outputs are non-isolated from the external 24V DC field supply and isolated from the system side by 50V continuous reinforced insulation, tested at 2500V DC for 60 s field side to system.

Which bases fit a 1734-OB8E?

1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS. The two-point 1734-OB2E also accepts 1734-TB3, 1734-TB3S, 1734-TOP3 and 1734-TOP3S, so a TB3 position can only take the two-point protected module.

How do I size the field supply?

The module itself draws 8 mA (1734-OB2E), 16 mA (1734-OB4E) or 32 mA (1734-OB8E) from the external 24V DC supply, and the load current passes through the same supply. Add the simultaneous load current to that figure when selecting the 1734-FPD or 1734-EP24DC.

Can I replace a 1734-OB8 with a 1734-OB8E without rewiring?

Yes. Both use the same 1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS base, the same terminal assignment (outputs 0 to 7 on terminals 0 to 7) and the same 10...28.8V DC window. The new module simply adds a red fault LED per channel.


Data sources. Technical values on this page come from Rockwell publication 1734-IN056-EN-E (POINT I/O Protected Output Module, catalog numbers 1734-OB2E, 1734-OB4E, 1734-OB8E, 1734-OB8EK, Series C) and 1734-UM001 (POINT I/O Digital and Analog Modules User Manual). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.