The 1734-VHSC24 is the counter slice with its own outputs: three 24V DC inputs, two isolated source outputs, four compare windows, and PWM plus pulse-generator modes that the plain encoder modules do not have.
It is the module to specify when the counter has to act on its own count - energise a valve at a preset, generate a pulse train, close a window - without waiting for a controller scan.
| 1734-IJ | 1-channel incremental encoder input, 5V DC differential, 1.0 MHz | IN STOCK |
| 1734-IK | 1-channel incremental encoder input, 24V DC differential, 1.0 MHz | IN STOCK |
| 1734-VHSC24 | very high speed counter, 3 x 24V DC inputs, 2 source outputs, 1.0 MHz | IN STOCK |
Number of counters |
1 |
Number of compare windows |
4 |
Output groups |
1 group of 2, isolated, sourcing |
Input voltage |
24V DC, A/Areturn, B/Breturn, Z/Zreturn |
Voltage, on-state, min |
12.5V DC |
Voltage, off-state, max |
1.8V DC |
Current, on-state, min |
5 mA |
Current, on-state, max |
10.2 mA at 24V DC or 6.1 mA at 15V DC |
Current, off-state, max |
0.250 mA |
Input frequency, max |
1.0 MHz counter and encoder X1 (no filter); 500 kHz X2; 250 kHz X4 |
Input filter selections |
Off, 10 us (50 kHz), 100 us (5 kHz), 1.0 ms (500 Hz), 10.0 ms (50 Hz) |
Output current, max |
0.5 A per output at 24V DC |
Output voltage drop |
<0.3V DC at 0.5 A |
Output leakage, off-state |
<0.5 mA |
Output delay time, off to on |
25 us, load dependent |
Counter range |
24-bit, 0...16,777,215, returned in a 32-bit word |
Operating modes |
Counter, Encoder X1/X2/X4, Period/Rate, Continuous/Rate, Rate Measurement, PWM, Pulse Generator |
POINTBus current, max |
180 mA @ 5V DC |
Power dissipation, max |
1.9 W at rated load |
Thermal dissipation, max |
6.5 BTU/hr at rated load |
Isolation voltage |
50V (continuous), basic insulation, tested at 1100V DC for 60 s, field to system |
Field power bus |
24V nominal, 10...28.8V DC |
Terminal base |
1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS |
Terminal base screw torque |
0.6 Nm (7 lb-in) |
Keyswitch position |
2 |
Wire size |
0.34...2.1 mm2 (22...14 AWG), 75 deg C or greater |
Dimensions, HxWxD |
56.6 x 12.1 x 77.5 mm |
Temperature, operating |
-20...55 deg C (-4...131 deg F) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN003 (module specifications) and 1734-UM003 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
A, B and Z inputs accept 24V DC with a 12.5V on-state threshold and 10.2 mA draw at 24V. The two source outputs switch 0.5 A at 24V DC with less than 0.3V drop and 25 us off-to-on delay. Four compare windows mean four independent setpoints on one count, each able to drive the outputs directly.
1.0 MHz in counter and X1 modes with the filter off, 500 kHz in X2, 250 kHz in X4. A 2500-line encoder read in X4 gives 10,000 counts per revolution but caps the axis at 250 kHz - about 25 revolutions per second. Above that, count in X1 and scale in logic.
Pulse width modulation and pulse generator modes exist on the 1734-VHSC24 and 1734-VHSC5 but not on the 1734-IJ or 1734-IK encoder modules. If the application needs a variable duty output or a defined-width pulse counted back, the plain encoder slices cannot do it, whatever the input frequency.
180 mA at 5V DC is one of the highest POINTBus draws in the family, and it is the number to use when totalling a 1734-AENT rack against its 1.0 A budget. Add 1.9 W of dissipation and 6.5 BTU/hr per slice at rated load - five of these in a rack is 9.5 W of internal heat before any field current.
Inputs are 24V DC only. A 5V differential encoder needs the 1734-VHSC5 instead; wiring a 5V encoder to the VHSC24 leaves every transition below the 12.5V on-state threshold and the count stays at zero. Isolation is 50V basic, tested at 1100V DC for 60 s, keyswitch position 2, and 0.6 Nm terminal torque on a base that also accepts the one-piece TOP and TOPS mouldings.
What makes 1734-VHSC24 different from 1734-IK?
It adds two isolated 0.5 A source outputs, four compare windows and PWM / pulse generator modes. The IK is a counter input only.
What input voltage does it accept?
24V DC on A, B and Z, with a 12.5V minimum on-state voltage, 10.2 mA at 24V, and 1.8V maximum off-state voltage. 5V encoders need the 1734-VHSC5.
How much can each output carry?
0.5 A at 24V DC with a maximum 0.3V drop, less than 0.5 mA off-state leakage and 25 us off-to-on delay.
What is the maximum counting frequency?
1.0 MHz in counter and encoder X1 modes with the filter off, 500 kHz in X2 and 250 kHz in X4.
How much POINTBus current does it draw?
180 mA at 5V DC, with 1.9 W dissipation and 6.5 BTU/hr at rated load, keyswitch position 2 and 50V basic isolation tested at 1100V DC for 60 s.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley POINT I/O 1734 modules category.