logo
Home ProductsAB SLC-500 Systems 1747

Allen Bradley PLC 1747-UIC / 1747UIC

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1747-UIC / 1747UIC

China Allen Bradley PLC 1747-UIC / 1747UIC supplier
Allen Bradley PLC 1747-UIC / 1747UIC supplier Allen Bradley PLC 1747-UIC / 1747UIC supplier Allen Bradley PLC 1747-UIC / 1747UIC supplier Allen Bradley PLC 1747-UIC / 1747UIC supplier Allen Bradley PLC 1747-UIC / 1747UIC supplier Allen Bradley PLC 1747-UIC / 1747UIC supplier Allen Bradley PLC 1747-UIC / 1747UIC supplier Allen Bradley PLC 1747-UIC / 1747UIC supplier

Large Image :  Allen Bradley PLC 1747-UIC / 1747UIC

Product Details:

Place of Origin: Made in INDIA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1747-UIC / 1747UIC

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $205.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1747-UIC technical data PDF download 1747-UIC SLC USB to DH-485 Converter

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: SLC 500 System 1747

1747-UIC is the SLC USB to DH-485 Converter.

Connects a personal computer USB port to a DH-485 network. 1747-UM011 pairs it with the 1747-C13 or 1747-CP3 cable and notes that a 1761-NET-AIC is needed when joining a DH-485 network. Rockwell lists the catalog number as discontinued on 2024-09-30, replacement category No planned RA replacement.

1747-SN SLC Remote I/O Scanner Module IN STOCK
1747-SCNR SLC ControlNet Scanner IN STOCK
1747-SDN SLC DeviceNet Scanner Module IN STOCK
1747-ASB SLC Remote I/O Adapter Module IN STOCK
1747-BSN SLC Backup Scanner Module IN STOCK
1747-ACN15 SLC ControlNet Adapter Module IN STOCK
1747-ACNR15 SLC ControlNet Adapter Module, redundant media IN STOCK
1747-DCM SLC Direct Communication Module IN STOCK
1747-KE Communication Interface Module, DH-485 to RS-232C IN STOCK
1747-KFC15 SLC Interface Module IN STOCK
1747-UIC SLC USB to DH-485 Converter IN STOCK
1747-UICC13 USB Converter Cable IN STOCK
1747-PIC SLC RS-232 to DH-485 Interface Converter IN STOCK
1747-AIC SLC Isolated Link Coupler IN STOCK
1747-DPS1 SLC Data Port Splitter IN STOCK
1747-DPS2 SLC Data Port Splitter IN STOCK

Product Specifications 1747-UIC (PDF)
 Catalog number
 1747-UIC
 Description
 SLC USB to DH-485 Converter
 Module type
 USB to DH-485 converter
 Channels
 USB port and DH-485 port
 Isolation
 Not published
 Rockwell class
 Signal converter
 Discontinued date
 2024-09-30
 Replacement category
 No planned RA replacement
 Replacement product
 None published
 Publication
 1747-UM011 / 1747-IN009

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1747-UM011 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1747-UIC 1747-UIC 1747-UIC

What the module does

Connects a personal computer USB port to a DH-485 network. 1747-UM011 pairs it with the 1747-C13 or 1747-CP3 cable and notes that a 1761-NET-AIC is needed when joining a DH-485 network.

It is a single-slot module for a 1746 chassis, powered from the rack backplane. Nothing in the chassis changes when it is fitted: the processor still occupies slot 0 of the first rack, and the module sits in any other slot.

Channels and electrical isolation

Rockwell prints USB port and DH-485 port for this catalog number, and no isolation figure on the product page.

Because no isolation figure is printed for this catalog number, treat the port as unspecified and confirm with a Rockwell publication before designing a network where common-mode noise is expected.

Where it sits in the SLC 500 network architecture

SLC 500 systems reach other devices over four routes: DH-485 for peer-to-peer and programming, DH+ for PLC-5 class networks, Remote I/O for scanner and adapter racks, and the fieldbus scanners for DeviceNet and ControlNet. Each route has a distinct module pair, and mixing them up is the commonest commissioning error.

This catalog number belongs to one of those routes. The module on the other side of the link has to match it: a scanner needs an adapter, and an adapter needs a scanner. Two adapters on the same link do nothing.

Fitting and commissioning

Set the node address and the baud rate before the module goes into the rack, record both on the panel schedule, and confirm the processor sees the module in its I/O configuration. A module that is fitted but not configured in the program behaves like a missing module, not like a fault.

On a working line, the safe sequence is: power down the rack, fit the module, power up with the processor in PROG, download the configuration, then switch to RUN and watch the module status for a full production cycle.

Lifecycle status and spares

Rockwell discontinued this catalog number on 2024-09-30 with replacement category No planned RA replacement.

Communication modules are the parts that fail first in an SLC 500 panel, because they carry the surge path. Keep a tested spare of the exact catalog number, and record the firmware or series letter of the working module next to it.

FAQ — 1747-UIC

What is 1747-UIC?

SLC USB to DH-485 Converter Connects a personal computer USB port to a DH-485 network. 1747-UM011 pairs it with the 1747-C13 or 1747-CP3 cable and notes that a 1761-NET-AIC is needed when joining a DH-485 network.

How many channels does 1747-UIC have?

Rockwell prints USB port and DH-485 port for this catalog number.

Is 1747-UIC still available from Rockwell?

No. Discontinued 2024-09-30, replacement category No planned RA replacement.

What is the isolation rating?

Not published.

Does 1747-UIC need a matching module at the other end of the link?

Yes. A scanner needs an adapter and an adapter needs a scanner on the same link.


Data sources. Channel counts and isolation figures come from the Rockwell product page of the catalog number; the role of each module in the network architecture is quoted from 1747-UM011. Catalog numbers whose Rockwell page has been withdrawn carry no channel or isolation figure on this page. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

The port side of the 1747 family: computer and DF1 access to DH-485

Eight catalog numbers sit between a computer or a DF1 device and the DH-485 link, and they are not alternatives to each other: one converts RS-232, one converts USB, one isolates the link, one bridges DF1, and two split a processor port. Reading the channel column is how the right one gets chosen.

CatalogWhat it isChannel printedIsolation printedLifecycle
1747-KEDH-485 to RS-232C interfaceOne DH-485 port and one RS-232C portNot published2013-12-01, No planned RA replacement
1747-KFC15Interface moduleNot publishedNot published2014-01-05, No planned RA replacement
1747-PICRS-232 to DH-485 converterRS-232 port and DH-485 portNot published2015-12-31, Engineering Replacement
1747-UICUSB to DH-485 converterUSB port and DH-485 portNot published2024-09-30, No planned RA replacement
1747-UICC13Interface cable for 1747-UICNot publishedNot publishedNot published, Not published
1747-AICIsolated link couplerDH-485 link coupling500V dc on communication circuits2017-01-31, Engineering Replacement
1747-DPS1Port splitterNot publishedNot publishedNot published, Not published
1747-DPS2Port splitterNot publishedNot publishedNot published, Not published

Where this converter sits: 1747-UIC is the USB to DH-485 converter, paired with the 1747-C13 or 1747-CP3 cable, so it sits at the PC side of the DH-485 link, on USB. On this page: the printed port line is "USB port and DH-485 port", while the isolation column carries no figure.

The port converters are the part of this family that is hardest to buy today: 2 of the eight on this list carry an engineering-replacement status and 7 publish no isolation figure, so a computer on a DH-485 link is usually built from a 1747-UIC plus the right cable rather than from the older converters. Cable pairing is printed per converter and is not interchangeable.

Source: Rockwell 1747-IN009, 1747-IN007, 1747-IN019, 1747-IN062, 1747-UM011 and 1747-RM001 as recorded per catalog number, plus the Rockwell product page for each number. Every figure is quoted as printed; no value is calculated.

Related numbers