Product Details:
Payment & Shipping Terms:
|
1747-UIC is the SLC USB to DH-485 Converter.
Connects a personal computer USB port to a DH-485 network. 1747-UM011 pairs it with the 1747-C13 or 1747-CP3 cable and notes that a 1761-NET-AIC is needed when joining a DH-485 network. Rockwell lists the catalog number as discontinued on 2024-09-30, replacement category No planned RA replacement.
| 1747-SN | SLC Remote I/O Scanner Module | IN STOCK |
| 1747-SCNR | SLC ControlNet Scanner | IN STOCK |
| 1747-SDN | SLC DeviceNet Scanner Module | IN STOCK |
| 1747-ASB | SLC Remote I/O Adapter Module | IN STOCK |
| 1747-BSN | SLC Backup Scanner Module | IN STOCK |
| 1747-ACN15 | SLC ControlNet Adapter Module | IN STOCK |
| 1747-ACNR15 | SLC ControlNet Adapter Module, redundant media | IN STOCK |
| 1747-DCM | SLC Direct Communication Module | IN STOCK |
| 1747-KE | Communication Interface Module, DH-485 to RS-232C | IN STOCK |
| 1747-KFC15 | SLC Interface Module | IN STOCK |
| 1747-UIC | SLC USB to DH-485 Converter | IN STOCK |
| 1747-UICC13 | USB Converter Cable | IN STOCK |
| 1747-PIC | SLC RS-232 to DH-485 Interface Converter | IN STOCK |
| 1747-AIC | SLC Isolated Link Coupler | IN STOCK |
| 1747-DPS1 | SLC Data Port Splitter | IN STOCK |
| 1747-DPS2 | SLC Data Port Splitter | IN STOCK |
Catalog number |
1747-UIC |
Description |
SLC USB to DH-485 Converter |
Module type |
USB to DH-485 converter |
Channels |
USB port and DH-485 port |
Isolation |
Not published |
Rockwell class |
Signal converter |
Discontinued date |
2024-09-30 |
Replacement category |
No planned RA replacement |
Replacement product |
None published |
Publication |
1747-UM011 / 1747-IN009 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1747-UM011 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Connects a personal computer USB port to a DH-485 network. 1747-UM011 pairs it with the 1747-C13 or 1747-CP3 cable and notes that a 1761-NET-AIC is needed when joining a DH-485 network.
It is a single-slot module for a 1746 chassis, powered from the rack backplane. Nothing in the chassis changes when it is fitted: the processor still occupies slot 0 of the first rack, and the module sits in any other slot.
Rockwell prints USB port and DH-485 port for this catalog number, and no isolation figure on the product page.
Because no isolation figure is printed for this catalog number, treat the port as unspecified and confirm with a Rockwell publication before designing a network where common-mode noise is expected.
SLC 500 systems reach other devices over four routes: DH-485 for peer-to-peer and programming, DH+ for PLC-5 class networks, Remote I/O for scanner and adapter racks, and the fieldbus scanners for DeviceNet and ControlNet. Each route has a distinct module pair, and mixing them up is the commonest commissioning error.
This catalog number belongs to one of those routes. The module on the other side of the link has to match it: a scanner needs an adapter, and an adapter needs a scanner. Two adapters on the same link do nothing.
Set the node address and the baud rate before the module goes into the rack, record both on the panel schedule, and confirm the processor sees the module in its I/O configuration. A module that is fitted but not configured in the program behaves like a missing module, not like a fault.
On a working line, the safe sequence is: power down the rack, fit the module, power up with the processor in PROG, download the configuration, then switch to RUN and watch the module status for a full production cycle.
Rockwell discontinued this catalog number on 2024-09-30 with replacement category No planned RA replacement.
Communication modules are the parts that fail first in an SLC 500 panel, because they carry the surge path. Keep a tested spare of the exact catalog number, and record the firmware or series letter of the working module next to it.
What is %s?
SLC USB to DH-485 Converter Connects a personal computer USB port to a DH-485 network. 1747-UM011 pairs it with the 1747-C13 or 1747-CP3 cable and notes that a 1761-NET-AIC is needed when joining a DH-485 network.
How many channels does %s have?
Rockwell prints USB port and DH-485 port for this catalog number.
Is %s still available from Rockwell?
No. Discontinued 2024-09-30, replacement category No planned RA replacement.
What is the isolation rating?
Not published.
Does %s need a matching module at the other end of the link?
Yes. A scanner needs an adapter and an adapter needs a scanner on the same link.