Product Details:
Payment & Shipping Terms:
|
2085-IM8 is a 8-point AC input module in the Micro800 expansion line. It reads 240 V AC field circuits directly, which is what a European or Asian panel needs when the control voltage is phase to phase rather than 120 V.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
| 2085-IA8 | 8-point 120 V AC input | IN STOCK |
| 2085-IM8 | 8-point 240 V AC input | IN STOCK |
| 2085-OA8 | 8-point 120/240 V AC triac output | IN STOCK |
| 2085-IQ32T | 32-point 12/24 V DC sink/source input | IN STOCK |
| 2085-OV16 | 16-point 12/24 V DC sink transistor output | IN STOCK |
| 2085-OB16 | 16-point 12/24 V DC source transistor output | IN STOCK |
| 2085-OW8 | 8-point AC/DC relay output | IN STOCK |
| 2085-OW16 | 16-point AC/DC relay output, 2 A | IN STOCK |
| 2085-IF4 | 4-channel 14-bit isolated analog input | IN STOCK |
| 2085-IF8 | 8-channel 14-bit isolated analog input | IN STOCK |
| 2085-OF4 | 4-channel 12-bit isolated analog output | IN STOCK |
| 2085-IRT4 | 4-channel 16-bit RTD and thermocouple input | IN STOCK |
| 2085-ECR | 2085 expansion bus terminator | IN STOCK |
Catalog number |
2085-IM8 |
Product type |
8-point AC input module |
Points / channels |
8 inputs |
Signal |
240 V AC, operating range 159-240 V AC |
Isolation |
Field wiring to controller |
Backplane current, 5 V DC |
180 mA |
Dimensions, H x W x D |
28 x 90 x 87 mm |
Temperature rating |
Per 2085-IN005 |
Lifecycle status |
Active |
UPC |
Not published |
Country of origin |
Not published |
Terminal block |
Removable terminal block (RTB) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2085-IN005 (module specifications) and 2080-UM003 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2085-IM8 is a 8-point AC input module in the Micro800 expansion line. It reads 240 V AC field circuits directly, which is what a European or Asian panel needs when the control voltage is phase to phase rather than 120 V.
It mounts to the right of a Micro810, Micro820, Micro830, Micro850 or Micro870 controller and is addressed by its position in the expansion chain, so the slot order in the project has to match the physical order.
Signal and channel count are fixed by the catalog number: 8 inputs, 240 V AC, operating range 159-240 V AC.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
Published input data: off-state voltage 40 V AC maximum, on-state current 4.0 mA minimum at 159 V AC and 7.0 mA maximum at 240 V AC, 22.2 kOhm maximum input impedance, 450 mA maximum inrush, 20 ms input filter, IEC Type 3.
Size the conductors and the torque to the module data sheet; the RTB screws are hand-tightened, not driven with a power tool.
Module order matters: the expansion chain is scanned in physical order, and the bus is ended with a terminator. It costs more bus current than the 120 V card: 180 mA against 150 mA, which matters on a long expansion chain.
Backplane draw is 180 mA. Add every module in the chain before deciding on the controller power budget.
Rockwell lists this catalog number as Active.
Dimensions are 28 x 90 x 87 mm and the rated ambient is Per 2085-IN005.
UPC is Not published, country of origin Not published.
Check that the module comes with its RTB. A module sold without the terminal block is not a drop-in swap, whatever the price difference.
Confirm the catalog number against the project: the 2085 line separates sink from source transistor outputs and AC input from DC input by catalog number only.
Do not substitute a 2085-IA8 for this module on a 240 V circuit: the 120 V card is rated 74 to 120 V AC.
What does 2085-IM8 do?
8-point AC input module: 8 inputs, 240 V AC, operating range 159-240 V AC.
Where does 2085-IM8 mount?
To the right of a Micro800 controller, in the expansion chain, connected through the 2085 bus.
How much backplane current does 2085-IM8 draw?
180 mA.
What are the dimensions of 2085-IM8?
28 x 90 x 87 mm, rated Per 2085-IN005.
Is 2085-IM8 a current Rockwell product?
Rockwell lists it as Active.
2085-IM8 is a 8 point 240V AC input module in the Micro800 system, and the specification rows below are the published data for this catalog number.
| Specification | Value |
|---|---|
| Catalog number | 2085-IM8, 8 point 240V AC input expansion module |
| Number of inputs | 8 |
| Voltage category | 240V AC |
| Operating voltage range | 159 to 240V AC |
| Off-state limits | 40V AC maximum, 2.5 mA maximum |
| On-state current | 4.0 mA minimum at 159V AC; 7.0 mA maximum at 240V AC |
| Input impedance | 22.2 kOhm maximum |
| Inrush current | 450 mA maximum |
| Input filter time | 20 ms or less, both off to on and on to off |
| IEC type compliance | Type 3 |
| Dimensions | 28 x 90 x 87 mm, 1.10 x 3.54 x 3.42 in |
| Source | 2080-TD001 Micro800 technical data, discrete AC input expansion I/O specifications |
One hundred and fifty nine volts is the on-state threshold at 240 volts nominal, which leaves a wide margin against a sagging supply, and forty volts of off-state tolerance is what a long unshielded run at 240 volts needs to stay off when it should.
Seven milliamps at 240 volts rather than twelve and a half at 120 is consistent with the same input power, and the shared twenty two point two kilohm impedance shows that both modules use the same front end with different thresholds.
The ranges, the currents and the filter time on this page are the published values for this catalog number, and the IEC type classification is quoted as published rather than interpreted.
An expansion module is a separate DIN rail device with its own terminal block, and that changes the wiring effort compared with a plug-in module. The 2085 family is what a Micro850 chassis accepts, up to four of them, and each one carries its own field terminals rather than borrowing the controller row.
Relay and transistor outputs on the same family look interchangeable on a drawing and are not interchangeable on a load. A relay at eight amps per module handles an inrush that a transistor output rated half an amp per point will not survive, and the load type decides which module is ordered.
Two hundred and twenty grams of shipping weight and an open style enclosure are the practical statements about these modules. They are panel mounted inside an enclosure, they are not field mounted, and the enclosure rating is the panel rating rather than the module rating.
Isolation on these modules is fifty volts continuous, reinforced insulation, channel to system, with a type test at seven hundred and fifteen volts DC for sixty seconds. That is a working isolation for a panel with a common reference, not a barrier for a hazardous area, and the two should not be confused.
Analog temperature modules carry an accuracy that depends on the sensor type. A thermocouple input specified within half a degree to three degrees and an RTD input within two tenths to six tenths of a degree are two very different measurement systems sharing one module.
Expansion modules share the controller supply and add to its consumption, so the power budget is cumulative. A controller published at eleven watts with no expansion and thirty three watts with plug-ins and expansion is telling the designer that the difference belongs to the modules that were added.
Forty four and a half millimetres of width is the physical unit of expansion planning. Five modules fit in a fraction of the rail space that five separate controllers would take, and the depth of eighty seven millimetres is what decides whether the panel is deep enough for the terminal cover.
The bus terminator is the part that makes the serial expansion bus electrically correct. It terminates the end of the chain, it is listed in the same technical data as the modules, and a chain without it is a chain that may work on the bench and fail in the panel.
The point count on an expansion module is a bus load as well as a field count. Sixteen discrete inputs draw one hundred and seventy milliamps from the five volt bus and thirty two draw one hundred and ninety, which is the figure the controller power budget has to absorb for every module in the chain.
Derating curves are published for a reason, and they are the part of a data sheet that gets skipped. A sixteen point DC input module with a published curve will carry its full count at one ambient and a reduced count at another, and the cabinet temperature is the variable that decides which.
A green health indicator and no channel indicators is a deliberate diagnostic style on some analog modules. The module tells you it is alive and the channel value tells you the rest, which means the troubleshooting tool is the programming software rather than a lamp.
The Type 1 input designation is a real classification, not marketing. IEC Type 1 inputs are the slow, tolerant sensors, and a module published against that standard is the right choice for a limit switch and the wrong one for a registration mark.
Channel update time on a temperature module is measured per enabled channel, not per module. Twelve to five hundred milliseconds per channel means a module with all channels enabled updates slowly, and a control loop that assumes a fast scan will be wrong about when the value arrived.
Use it for 240 volt AC field devices, and keep the wide on-state margin in mind when the supply sags under load.
Browse the Allen-Bradley Micro and Nano systems category for the other models, options and spare parts that share this range.