Product Details:
Payment & Shipping Terms:
|
The 2080-LC30-10QVB swaps the four relay outputs for 24 V DC sink outputs and adds one PTO and two high-speed counters.
Rockwell's Micro830 table shows the QVB variants as the motion-capable ones: the transistor outputs can pulse, which a relay cannot.
| 2080-LC10-12AWA | Micro810, 8 AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QWB | Micro810, 8 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QBB | Micro810, 8 DC/AC in / 4 DC source out | IN STOCK |
| 2080-LC10-12DWD | Micro810, 8 12V DC in / 4 relay out | IN STOCK |
| 2080-LC20-20AWB | Micro820, 12 AC in / 8 relay out | IN STOCK |
| 2080-LC20-20QWB | Micro820, 12 DC in / 8 relay out | IN STOCK |
| 2080-LC20-20QBB | Micro820, 12 DC in / 8 DC source out | IN STOCK |
| 2080-LC20-20AWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QBBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC30-10QWB | Micro830, 6 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC30-10QVB | Micro830, 6 DC/AC in / 4 DC sink out | IN STOCK |
| 2080-LC30-16AWB | Micro830, 10 AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QWB | Micro830, 10 DC/AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QVB | Micro830, 10 DC/AC in / 6 DC sink out | IN STOCK |
| 2080-LC30-24QWB | Micro830, 14 DC/AC in / 10 relay out | IN STOCK |
| 2080-LC30-24QVB | Micro830, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC30-24QBB | Micro830, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC30-48AWB | Micro830, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QWB | Micro830, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QVB | Micro830, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-24AWB | Micro850, 14 AC in / 10 relay out | IN STOCK |
| 2080-LC50-24QVB | Micro850, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC50-24QBB | Micro850, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC50-48AWB | Micro850, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QWB | Micro850, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QVB | Micro850, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-48QBB | Micro850, 28 DC/AC in / 20 DC source out | IN STOCK |
Catalog number |
2080-LC30-10QVB |
Family |
Micro830 brick controller |
I/O points |
10 (6 inputs, 4 sink outputs) |
Inputs |
6 inputs, 24 V DC or 24 V AC |
Outputs |
4 outputs, 24 V DC sink |
Supply |
24 V DC Class 2 through the optional power supply slot |
Communication |
USB 2.0 Type B programming port and RS-232/RS-485 non-isolated combo serial port |
Plug-in modules |
2 plug-in slots |
Dimensions, H x W x D |
90 x 100 x 80 mm |
Shipping weight |
See 2080-UM002 table |
Temperature rating |
-20 to 65 C (-4 to 149 F) |
Power consumption, max |
5 W |
Lifecycle |
Listed in the current Micro830 catalog table of 2080-UM002 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-UM002 (module specifications) and 2080-UM002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 2080-LC30-10QVB swaps the four relay outputs for 24 V DC sink outputs and adds one PTO and two high-speed counters.
Rockwell's Micro830 table shows the QVB variants as the motion-capable ones: the transistor outputs can pulse, which a relay cannot.
It is the ten-point Micro830 for a small axis, an encoder or a pulse-counting application.
Sink output means the load is tied to the positive rail and the controller pulls it to 0 V.
The embedded high-speed counters are the reason to pick this model over the relay version when an encoder is involved.
Inputs are 24 V DC or 24 V AC; the outputs are transistor, so no AC load can be switched directly.
Communication and capacity. USB 2.0 Type B programming port and RS-232/RS-485 non-isolated combo serial port
2 plug-in slots plug-in modules can be fitted, each drawing about 1.44 W of the controller's internal budget.
Connected Components Workbench is the programming environment for the whole family, so a project built for one Micro800 controller converts to another with the I/O reassigned.
Mounting is DIN rail or panel, 90 x 100 x 80 mm, shipping See 2080-UM002 table.
Rated ambient -20 to 65 C (-4 to 149 F), maximum consumption 5 W.
Lifecycle. Listed in the current Micro830 catalog table of 2080-UM002
Two plug-in slots, 5 W base consumption, 90 x 100 x 80 mm.
One PTO output and two HSC inputs are listed for this catalog in 2080-UM002 Table 1.
Rockwell's Micro830 catalog table still lists this catalog number.
How many I/O points does 2080-LC30-10QVB have?
Micro830 brick controller: 10 (6 inputs, 4 sink outputs).
What is the input type on 2080-LC30-10QVB?
6 inputs, 24 V DC or 24 V AC.
What does 2080-LC30-10QVB use for communication?
USB 2.0 Type B programming port and RS-232/RS-485 non-isolated combo serial port.
What are the dimensions of 2080-LC30-10QVB?
90 x 100 x 80 mm, See 2080-UM002 table.
What is the lifecycle status of 2080-LC30-10QVB?