2085-OW16 is a 16-point relay output module in the Micro800 expansion line. It is the 16-point relay card of the line: sixteen dry contacts on one expansion slot, for panels that switch a mixture of AC and DC loads.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
| 2085-IA8 | 8-point 120 V AC input | IN STOCK |
| 2085-IM8 | 8-point 240 V AC input | IN STOCK |
| 2085-OA8 | 8-point 120/240 V AC triac output | IN STOCK |
| 2085-IQ32T | 32-point 12/24 V DC sink/source input | IN STOCK |
| 2085-OV16 | 16-point 12/24 V DC sink transistor output | IN STOCK |
| 2085-OB16 | 16-point 12/24 V DC source transistor output | IN STOCK |
| 2085-OW8 | 8-point AC/DC relay output | IN STOCK |
| 2085-OW16 | 16-point AC/DC relay output, 2 A | IN STOCK |
| 2085-IF4 | 4-channel 14-bit isolated analog input | IN STOCK |
| 2085-IF8 | 8-channel 14-bit isolated analog input | IN STOCK |
| 2085-OF4 | 4-channel 12-bit isolated analog output | IN STOCK |
| 2085-IRT4 | 4-channel 16-bit RTD and thermocouple input | IN STOCK |
| 2085-ECR | 2085 expansion bus terminator | IN STOCK |
Catalog number |
2085-OW16 |
Product type |
16-point relay output module |
Points / channels |
16 outputs |
Signal |
12/24 V DC coil, relay contacts rated 2 A |
Isolation |
Isolated, field wiring to controller |
Backplane current, 5 V DC |
Not published |
Dimensions, H x W x D |
90 x 87 mm (height and depth) |
Temperature rating |
-20 to 65 C (-4 to 149 F) |
Lifecycle status |
Active |
UPC |
885630082332 |
Country of origin |
Singapore |
Terminal block |
Removable terminal block (RTB) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-UM003 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2085-OW16 is a 16-point relay output module in the Micro800 expansion line. It is the 16-point relay card of the line: sixteen dry contacts on one expansion slot, for panels that switch a mixture of AC and DC loads.
It mounts to the right of a Micro810, Micro820, Micro830, Micro850 or Micro870 controller and is addressed by its position in the expansion chain, so the slot order in the project has to match the physical order.
Signal and channel count are fixed by the catalog number: 16 outputs, 12/24 V DC coil, relay contacts rated 2 A.
Field wiring lands on the removable terminal block (RTB). The RTB can be unplugged with the wiring in place, which is the reason a failed module can be swapped without re-terminating a panel.
Rockwell prints the contact rating as 2 A and describes the module as a 16 point relay output for the Micro850 system, with LED status indication per point.
Size the conductors and the torque to the module data sheet; the RTB screws are hand-tightened, not driven with a power tool.
Module order matters: the expansion chain is scanned in physical order, and the bus is ended with a terminator. The module is 90 mm high and 87 mm deep, the same footprint as the rest of the 2085 line, so it fits the standard DIN rail depth used with these controllers.
Backplane draw is Not published. Add every module in the chain before deciding on the controller power budget.
Rockwell lists this catalog number as Active.
Dimensions are 90 x 87 mm (height and depth) and the rated ambient is -20 to 65 C (-4 to 149 F).
UPC is 885630082332, country of origin Singapore.
Check that the module comes with its RTB. A module sold without the terminal block is not a drop-in swap, whatever the price difference.
Confirm the catalog number against the project: the 2085 line separates sink from source transistor outputs and AC input from DC input by catalog number only.
Contact rating is the number to check first: 2 A is a pilot duty rating, not a motor load rating.
What does 2085-OW16 do?
16-point relay output module: 16 outputs, 12/24 V DC coil, relay contacts rated 2 A.
Where does 2085-OW16 mount?
To the right of a Micro800 controller, in the expansion chain, connected through the 2085 bus.
How much backplane current does 2085-OW16 draw?
Not published.
What are the dimensions of 2085-OW16?
90 x 87 mm (height and depth), rated -20 to 65 C (-4 to 149 F).
Is 2085-OW16 a current Rockwell product?
Rockwell lists it as Active.
2085-OW16 is a 16 point relay output module in the 2085 expansion family, and the contact table below is the published relay rating for this module rather than a general statement about relay outputs.
| Specification | Value |
|---|---|
| Catalog number | 2085-OW16, 16 point AC/DC relay output expansion module |
| Number of outputs | 16 relay |
| Dimensions | 44.5 x 90 x 87 mm, 1.75 x 3.54 x 3.42 in |
| Shipping weight | Approximately 300 g, 10.58 oz |
| Bus current draw | 160 mA at 5V DC, 100 mA at 24V DC, maximum |
| Power dissipation | 5.14 W total |
| Status indicators | 16 yellow channel indicators |
| Variant | 2085-OW16K is the conformally coated version of this module |
| Relay contact rating at 120V AC | Make 15 A, break 1.5 A, continuous 2.0 A, 1800 VA make and 180 VA break, at 0.35 power factor |
| Relay contact rating at 240V AC | Make 7.5 A, break 0.75 A, continuous 2.0 A |
| Relay contact rating at 24V DC | Make 1.0 A, break 1.0 A, 28 VA |
| Relay contact rating at 125V DC | Make 0.22 A, break 0.22 A |
| Load current, maximum | 2 A per point |
| Minimum load per point | 10 mA |
| Off-state leakage | 1.5 mA maximum |
| Pilot duty rating | C300, R150 |
| Isolation voltage | 240V continuous, reinforced insulation, channel to system |
| Enclosure | Open style, no enclosure rating |
| North American temperature code | T4 |
| Source | 2080-TD001 Micro800 technical data, discrete relay output expansion I/O specifications |
Sixteen relays in forty four and a half millimetres with five point one four watts of dissipation is a heat load that belongs in the panel calculation. A cabinet with two of these and a controller has a warm corner, and the ambient derating of the adjacent solid state modules depends on it.
The one hundred and twenty five volt DC rating at two hundred and twenty milliamps is the contact set behaving as a DC switch: the arc does not self extinguish, so the DC rating is a fraction of the AC rating at the same contact. A DC solenoid on this module is a smaller load than the AC figure suggests.
The contact ratings on this page are the published values for the relay output expansion modules, including the make and break distinction and the pilot duty classification, because those two rows decide whether a contactor can be driven directly.
The bus terminator is the part that makes the serial expansion bus electrically correct. It terminates the end of the chain, it is listed in the same technical data as the modules, and a chain without it is a chain that may work on the bench and fail in the panel.
The point count on an expansion module is a bus load as well as a field count. Sixteen discrete inputs draw one hundred and seventy milliamps from the five volt bus and thirty two draw one hundred and ninety, which is the figure the controller power budget has to absorb for every module in the chain.
Derating curves are published for a reason, and they are the part of a data sheet that gets skipped. A sixteen point DC input module with a published curve will carry its full count at one ambient and a reduced count at another, and the cabinet temperature is the variable that decides which.
A green health indicator and no channel indicators is a deliberate diagnostic style on some analog modules. The module tells you it is alive and the channel value tells you the rest, which means the troubleshooting tool is the programming software rather than a lamp.
The Type 1 input designation is a real classification, not marketing. IEC Type 1 inputs are the slow, tolerant sensors, and a module published against that standard is the right choice for a limit switch and the wrong one for a registration mark.
Channel update time on a temperature module is measured per enabled channel, not per module. Twelve to five hundred milliseconds per channel means a module with all channels enabled updates slowly, and a control loop that assumes a fast scan will be wrong about when the value arrived.
An expansion module is a separate DIN rail device with its own terminal block, and that changes the wiring effort compared with a plug-in module. The 2085 family is what a Micro850 chassis accepts, up to four of them, and each one carries its own field terminals rather than borrowing the controller row.
Relay and transistor outputs on the same family look interchangeable on a drawing and are not interchangeable on a load. A relay at eight amps per module handles an inrush that a transistor output rated half an amp per point will not survive, and the load type decides which module is ordered.
Two hundred and twenty grams of shipping weight and an open style enclosure are the practical statements about these modules. They are panel mounted inside an enclosure, they are not field mounted, and the enclosure rating is the panel rating rather than the module rating.
Isolation on these modules is fifty volts continuous, reinforced insulation, channel to system, with a type test at seven hundred and fifteen volts DC for sixty seconds. That is a working isolation for a panel with a common reference, not a barrier for a hazardous area, and the two should not be confused.
Analog temperature modules carry an accuracy that depends on the sensor type. A thermocouple input specified within half a degree to three degrees and an RTD input within two tenths to six tenths of a degree are two very different measurement systems sharing one module.
Expansion modules share the controller supply and add to its consumption, so the power budget is cumulative. A controller published at eleven watts with no expansion and thirty three watts with plug-ins and expansion is telling the designer that the difference belongs to the modules that were added.
Forty four and a half millimetres of width is the physical unit of expansion planning. Five modules fit in a fraction of the rail space that five separate controllers would take, and the depth of eighty seven millimetres is what decides whether the panel is deep enough for the terminal cover.
Count the 5.14 W and the 300 g on the rail, respect the DC contact derating, and use the per channel indicators as the first diagnostic.
This part sits in the Allen-Bradley Micro and Nano systems category, with the other models and spare parts listed alongside it.