Product Details:
Payment & Shipping Terms:
|
The 2080-LC20-20AWB is the AC-input Micro820: twelve inputs, eight relay outputs and an embedded Ethernet port on a 20-point brick.
Rockwell builds the Micro820 for smaller standalone machines and remote automation, with a microSD slot for data logging and recipes and a remote LCD option for setting an IP address at the panel.
| 2080-LC10-12AWA | Micro810, 8 AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QWB | Micro810, 8 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC10-12QBB | Micro810, 8 DC/AC in / 4 DC source out | IN STOCK |
| 2080-LC10-12DWD | Micro810, 8 12V DC in / 4 relay out | IN STOCK |
| 2080-LC20-20AWB | Micro820, 12 AC in / 8 relay out | IN STOCK |
| 2080-LC20-20QWB | Micro820, 12 DC in / 8 relay out | IN STOCK |
| 2080-LC20-20QBB | Micro820, 12 DC in / 8 DC source out | IN STOCK |
| 2080-LC20-20AWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QWBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC20-20QBBR | Micro820 with removable terminal blocks | IN STOCK |
| 2080-LC30-10QWB | Micro830, 6 DC/AC in / 4 relay out | IN STOCK |
| 2080-LC30-10QVB | Micro830, 6 DC/AC in / 4 DC sink out | IN STOCK |
| 2080-LC30-16AWB | Micro830, 10 AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QWB | Micro830, 10 DC/AC in / 6 relay out | IN STOCK |
| 2080-LC30-16QVB | Micro830, 10 DC/AC in / 6 DC sink out | IN STOCK |
| 2080-LC30-24QWB | Micro830, 14 DC/AC in / 10 relay out | IN STOCK |
| 2080-LC30-24QVB | Micro830, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC30-24QBB | Micro830, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC30-48AWB | Micro830, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QWB | Micro830, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC30-48QVB | Micro830, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-24AWB | Micro850, 14 AC in / 10 relay out | IN STOCK |
| 2080-LC50-24QVB | Micro850, 14 DC/AC in / 10 DC sink out | IN STOCK |
| 2080-LC50-24QBB | Micro850, 14 DC/AC in / 10 DC source out | IN STOCK |
| 2080-LC50-48AWB | Micro850, 28 AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QWB | Micro850, 28 DC/AC in / 20 relay out | IN STOCK |
| 2080-LC50-48QVB | Micro850, 28 DC/AC in / 20 DC sink out | IN STOCK |
| 2080-LC50-48QBB | Micro850, 28 DC/AC in / 20 DC source out | IN STOCK |
Catalog number |
2080-LC20-20AWB |
Family |
Micro820 20-point Ethernet controller |
I/O points |
20 (12 inputs, 8 relay outputs) |
Inputs |
12 inputs, 120 V AC on inputs 4 to 11; inputs 0 to 3 are 24 V DC |
Outputs |
8 relay outputs, 2 A at 240 V AC and 1 A at 24 V DC |
Supply |
24 V DC Class 2, 20.4 to 26.4 V DC |
Communication |
USB 2.0 (USB-C on the 2080-L20E), 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial, microSD slot for data logging and recipes |
Plug-in modules |
2 plug-in slots |
Dimensions, H x W x D |
90 x 104 x 75 mm |
Shipping weight |
0.38 kg |
Temperature rating |
-20 to 65 C (-4 to 149 F) |
Power consumption, max |
5.62 W without plug-ins, 8.5 W with |
Lifecycle |
Active |
Removable terminal blocks |
Fixed terminal blocks |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-TD001 (module specifications) and 2080-TD001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 2080-LC20-20AWB is the AC-input Micro820: twelve inputs, eight relay outputs and an embedded Ethernet port on a 20-point brick.
It is the controller for a machine that has to be visible on a plant network but does not need expansion I/O.
Rockwell's table is specific: the 120 V AC input circuit applies to inputs 4 to 11 only, and inputs 0 to 3 are 24 V DC.
Relay outputs are rated 2 A at 240 V AC and 1 A at 24 V DC; pilot duty C300, R150.
Terminal torque is 0.22 to 0.25 Nm with a 0.4 x 2.5 mm screwdriver.
Communication and capacity. USB 2.0 (USB-C on the 2080-L20E), 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial, microSD slot for data logging and recipes
2 plug-in slots plug-in modules can be fitted, each drawing about 1.44 W of the controller's internal budget.
Connected Components Workbench is the programming environment for the whole family, so a project built for one Micro800 controller converts to another with the I/O reassigned.
Mounting is DIN rail or panel, 90 x 104 x 75 mm, shipping 0.38 kg.
Rated ambient -20 to 65 C (-4 to 149 F), maximum consumption 5.62 W without plug-ins, 8.5 W with.
Lifecycle. Active
Twenty points, two plug-in slots, and up to 35 digital I/O with 8-point plug-ins in both slots.
An embedded 0 to 10 V analog output is available on the Micro820 base, which is unusual at this size.
Rockwell lists it as Active.
How many I/O points does 2080-LC20-20AWB have?
Micro820 20-point Ethernet controller: 20 (12 inputs, 8 relay outputs).
What is the input type on 2080-LC20-20AWB?
12 inputs, 120 V AC on inputs 4 to 11; inputs 0 to 3 are 24 V DC.
What does 2080-LC20-20AWB use for communication?
USB 2.0 (USB-C on the 2080-L20E), 10/100 Base-T Ethernet RJ45, RS-232/RS-485 non-isolated combo serial, microSD slot for data logging and recipes.
What are the dimensions of 2080-LC20-20AWB?
90 x 104 x 75 mm, 0.38 kg.
What is the lifecycle status of 2080-LC20-20AWB?
Active.
2080-LC20-20AWB is a 20 point Micro820 controller with AC and DC inputs and relay outputs in the Micro800 family, and the point table below is the published configuration for this catalog number rather than a family summary.
| Specification | Value |
|---|---|
| Catalog number | 2080-LC20-20AWB, Micro820 controller, 20 point, AC input, relay output |
| Inputs | 8 inputs at 120V AC and 4 inputs at 24V DC |
| Outputs | 7 relay outputs |
| Analog output | 1 channel of 0 to 10V DC |
| Analog inputs | 4 channels of 0 to 10V, shared with four of the 24V DC inputs |
| Plug-in slots | 2 |
| Communication | USB 2.0, 10/100 Base-T Ethernet, RS-232/RS-485 combo serial |
| Source | 2080-SG001 Micro800 selection guide, Micro820 controllers input and output table |
Mixing eight 120 volt AC inputs with four 24 volt DC inputs on one controller is unusual and useful: the AC channels take pushbuttons and limit switches from the existing panel, while the DC channels take the sensors that need the faster response.
The analog input sharing applies only to the four DC channels, so the analog budget on this model is four channels and it consumes the DC inputs to get them. That is a planning constraint worth stating before the tag list is frozen.
The point mix, the communication ports and the analog channel sharing on this page are taken from the Micro800 selection guide entry for this catalog number. Where a feature depends on a firmware revision, the row states the revision rather than implying it is universal.
Firmware revision gates features on these controllers. EtherNet/IP Class 1 connections to drives and remote LCD support arrive at specific revisions, and a controller from stock may predate them, so the revision belongs in the commissioning checklist rather than in the brochure.
Power supply choice follows from the input type, not from the output type. A controller with 120 to 240 volt AC inputs takes its field power from the same source that feeds the inputs, while a 24 volt DC input model needs a separate supply and puts that supply on the bill of materials.
The microSD slot is a maintenance feature more than a data feature. Project backup and restore from a card is what allows a service technician to replace a controller without a laptop and the original project file, and data logging and recipes are the secondary uses.
Conformal coating suffixes exist across the family for the same reason they exist elsewhere: condensing humidity, corrosive atmospheres and washdown areas. The suffix changes the materials, not the point mix, and the electrical ratings stay with the base catalog number.
Analog channels shared with digital inputs are a compromise worth understanding. Four 24 volt DC inputs can be configured as 0 to 10 volt analog inputs on the DC input models, which means the channel count is shared rather than added, and a machine that needs both cannot have both.
Plug-in modules and expansion modules are different form factors with different buses. A plug-in module sits in a slot inside the controller housing and shares its power, while an expansion module is a separate DIN rail device with its own terminal blocks, and the wiring effort differs accordingly.
The 2080 numbering carries the point mix in the suffix. AC input models are A, DC input models are Q, and the last letters describe the outputs: W for relay, V for sink, B for source. Reading the suffix is faster than opening the selection guide, and it is the same logic the family uses for expansion modules.
Communication ports on a small controller decide the architecture as much as the I/O does. An embedded Ethernet port with four Class 1 nodes is enough for a drive and a panel, and a serial port with Modbus RTU is enough for a weigh scale, but a machine that needs both protocols on multiple devices has outgrown the compact model.
A twelve point controller with relay outputs is a smart relay replacement, and the design intent is visible in the function blocks: delay on and off, time of day, time of week and time of year are built in rather than programmed, which is what a lighting or pump alternation panel needs.
Rated outputs are the reason these controllers exist in machine building. Two eight amp and two four amp relay outputs on the smallest model remove the external interposing relays for a small pump or a lamp, and the eight amp figure is per output with a total module limit that has to be read before the loads are added up.
The remote LCD module is a configuration aid, not an operator interface. It sets an IP address and shows a text display for a compact controller that has no screen, and its IP65 rating is the reason it can be mounted on the outside of an enclosure rather than behind the door.
A Micro800 controller is specified by the point mix rather than by the point count. Two catalogs with twenty points can carry eight AC inputs and seven relays, or twelve DC inputs and seven relays with an analog output, and the drawing that assumed the wrong mix has to be redone at the terminal level.
Expansion capacity is a hard number, not a suggestion. Micro850 controllers accept up to four expansion modules, and the 2085 family is the one that fits them, while the 2080 plug-in modules occupy the two plug-in slots on the compact models. Mixing the two kinds of expansion is a common ordering error.
Choose it where AC field devices dominate but a few fast DC sensors and analog channels are still needed.
Related models, options and spare parts for this range are listed in the Allen-Bradley Micro and Nano systems category.