Product Details:
Payment & Shipping Terms:
|
2080-IF2 is a 2-channel analog input plug-in the Bulletin 2080 Micro800 plug-in family. It adds two analog inputs to a controller that has no analog I/O on the base unit, at 12-bit resolution over 0-10 V or 0-20 mA.
A plug-in module snaps into a slot on the controller itself, so the I/O count grows without adding a DIN rail footprint or an expansion bus module.
| 2080-IF2 | 2-channel analog input plug-in | IN STOCK |
| 2080-IF4 | 4-channel analog input plug-in | IN STOCK |
| 2080-OF2 | 2-channel analog output plug-in | IN STOCK |
| 2080-TC2 | 2-channel thermocouple plug-in | IN STOCK |
| 2080-RTD2 | 2-channel RTD plug-in | IN STOCK |
| 2080-TRIMPOT6 | 6-channel trimpot analog input | IN STOCK |
| 2080-OB4 | 4-point DC source output plug-in | IN STOCK |
| 2080-OV4 | 4-point DC sink output plug-in | IN STOCK |
| 2080-OW4I | 4-point relay output plug-in | IN STOCK |
| 2080-IQ4OV4 | 8-point combo, 4 in / 4 out sink | IN STOCK |
| 2080-IQ4OB4 | 8-point combo, 4 in / 4 out source | IN STOCK |
| 2080-SERIALISOL | isolated RS-232/RS-485 serial plug-in | IN STOCK |
| 2080-MOT-HSC | high-speed counter plug-in | IN STOCK |
| 2080-MEMBAK-RTC | memory backup with real-time clock | IN STOCK |
| 2080-USBADAPTER | Micro810 USB adapter | IN STOCK |
| 2080-LCD | Micro810 LCD display with keypad | IN STOCK |
| 2080-REMLCD | Micro820 remote LCD display | IN STOCK |
| 2080-PS120-240VAC | 120/240 V AC to 24 V DC power supply | IN STOCK |
Catalog number |
2080-IF2 |
Product type |
2-channel analog input plug-in |
Channels / points |
2 channels |
Signal |
0-10 V DC, 0-20 mA, unipolar |
Isolation |
Non-isolated |
Resolution |
12-bit |
Controller compatibility |
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810 |
Dimensions, H x W x D |
62 x 31.5 x 20 mm |
Temperature rating |
Per 2080-UM004 |
Lifecycle status |
Active |
UPC |
Not published |
Country of origin |
Not published |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2080-WD003 (module specifications) and 2080-UM004 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2080-IF2 is a 2-channel analog input plug-in the Bulletin 2080 Micro800 plug-in family. It adds two analog inputs to a controller that has no analog I/O on the base unit, at 12-bit resolution over 0-10 V or 0-20 mA.
A plug-in module snaps into a slot on the controller itself, so the I/O count grows without adding a DIN rail footprint or an expansion bus module.
Channel count and signal type are fixed by the catalog number: 2 channels, 0-10 V DC, 0-20 mA, unipolar.
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810
The module is configured in Connected Components Workbench, not by a hardware switch, so the project file has to match the module that is physically fitted.
Micro810 controllers have no plug-in slots at all; the Micro810 accessories take the USB or display port instead.
Input impedance is above 100 kOhm in voltage mode and 250 Ohm in current mode, and the module draws less than 60 mA at 3.3 V. Weight is about 21 g, terminal torque 0.22 to 0.25 Nm with a 2.5 mm screwdriver.
Every plug-in this family is rated for the same panel environment, and the terminal block is the part that decides whether a swap is quick or not.
Isolation is Non-isolated. Where that matters, it is stated per model rather than assumed for the whole family.
Rockwell lists this catalog number as Active.
Dimensions are 62 x 31.5 x 20 mm, rated ambient Per 2080-UM004.
UPC is Not published, country of origin Not published.
A used plug-in is only worth fitting if the terminal block and the retaining clips are intact; the clips are what holds the module against vibration.
Match the catalog number exactly. The family contains pairs that differ only in sink versus source output or isolation, and the front label is the only reliable identifier once the box is gone.
Two transmitters on a single plug-in is the usual reason to buy it: a pressure transmitter and a level probe, with no expansion module and no extra DIN rail.
What does 2080-IF2 do?
2-channel analog input plug-in: 2 channels, 0-10 V DC, 0-20 mA, unipolar.
Which controllers accept 2080-IF2?
Micro820, Micro830 and Micro850 plug-in slots; not supported on Micro810
What is the resolution of 2080-IF2?
12-bit.
What are the dimensions of 2080-IF2?
62 x 31.5 x 20 mm, rated Per 2080-UM004.
Is 2080-IF2 still available from Rockwell?
Rockwell lists it as Active.
2080-IF2 is a 2 channel non-isolated analog input plug-in module in the Micro800 system, and the analog specification rows below are the published values for this catalog number, including the drift and overload rows that are usually omitted.
| Specification | Value |
|---|---|
| Catalog number | 2080-IF2, 2 channel unipolar non-isolated analog input plug-in module |
| Number of inputs | 2 unipolar, non-isolated |
| Voltage range | 0 to 10V DC |
| Current range | 0 to 20 mA |
| Input impedance | Over 100 kOhm in voltage mode; 250 Ohm in current mode |
| Resolution | 12 bits unipolar maximum, with software selected filtering at 50 Hz, 60 Hz, 250 Hz or 500 Hz |
| Data range | 0 to 65535 |
| Accuracy | Plus or minus 1 percent of full scale at 25 degrees C on both terminals |
| Non-linearity | Plus or minus 0.1 percent of full scale |
| Repeatability | Plus or minus 0.1 percent |
| Variant | 2080-IF2K is the conformally coated version |
| Source | 2080-TD001 Micro800 technical data, analog input plug-in module specifications |
Two channels in a plug-in slot is the minimum analog capability for a compact controller, and it exists because a Micro820 has two plug-in slots that would otherwise be empty. The channel count and the cost follow the slot, not the process.
The software filter selection between fifty, sixty, two hundred and fifty and five hundred hertz is what makes a non-isolated input usable next to a drive. Choosing the wrong notch frequency is the difference between a stable reading and a value that beats at the line frequency.
Resolution, accuracy, drift and update rate are kept separate on this page because they answer different questions. Where the source publishes a range that depends on the filter setting or the enabled channel count, the range is reproduced rather than collapsed to one number.
Output channels hold zero until they are configured. A drive reference or a valve positioner that sees zero on a download is a safe behaviour, and a program that assumes the previous value is retained will be wrong after every power cycle.
Sensor type coverage on a temperature module is a list, not a guarantee of accuracy. The published accuracy range spans the whole list, so the actual error for one thermocouple type has to be read from the type specific table rather than from the headline.
Overload tolerance is a commissioning feature. Thirty volts or thirty two milliamps continuous on one channel at a time is what protects the module from a miswired transmitter during a loop check, and it is also a warning that the protection is per channel rather than per module.
Accuracy figures published at twenty five degrees are laboratory figures. The drift per degree is what the panel actually sees, and a cabinet that runs twenty degrees above ambient multiplies the drift into a real error that belongs in the loop calculation.
Current loops are the default for a reason. Four to twenty milliamps survives voltage drop on a long cable and it has a live zero, so a broken wire reads as an under-range value rather than as zero percent of the process, and that difference is what lets the program detect a fault.
Factory calibration with no customer calibration supported is a statement about the service model. The module is replaced rather than trimmed, and a spare belongs on the shelf if the process cannot wait for a shipment.
Data format matters at the programming boundary. Left justified sixteen bit twos complement means the raw value occupies the high bits and the low bits are padding, and a scaling block that assumes right justification produces a value sixteen times too small.
Input impedance separates the two terminals completely. A voltage input above one megaohm barely loads the source, while a current input below one hundred ohms is the burden resistor, and connecting a four to twenty milliamp transmitter to the voltage terminal is a wiring error that reads as a saturated value.
The resistive load window on a milliamp output is the voltage budget of the loop. Fifteen to five hundred ohms at twenty four volts means the loop can carry a reasonable field impedance, and a device outside that window needs a different output or an interposing converter.
An analog channel is specified by four numbers that have to agree with each other: the resolution, the absolute accuracy, the drift with temperature and the update rate. A design that quotes only the resolution is quoting the smallest step the converter can produce, not the accuracy of the value it produces.
Fifty and sixty hertz rejection is the filter that decides how fast the channel can be. Enabling the rejection raises the settled response from a few milliseconds to hundreds, which is a fine trade for a temperature or a level, and an impossible one for a torque loop.
A plug-in analog module is a compromise on isolation and on channel count, and it is priced accordingly. Four non-isolated unipolar channels in a controller slot solve a small machine, and the same four channels in an isolated expansion module solve a panel with several supplies.
Bipolar and unipolar ranges change the resolution arithmetic. A twelve bit unipolar converter divides its span into four thousand and ninety six steps, and the same converter configured bipolar divides the same span into two thousand and forty eight steps on each side, which halves the step size claim.
Use it where two analog channels complete a compact controller, and keep the loop grounded to the same reference as the controller.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley Micro and Nano systems category.