Product Details:
Payment & Shipping Terms:
|
1762-IQ8 is a 1762 expansion module for the MicroLogix 1200 and 1500: 8 point 24v dc sink/source input module.
Expansion modules clip onto the controller bus and appear as extra I/O in the same data files, with no special programming. A 1200 brick carries up to six of them, and the platform is still orderable — most 1762 I/O is listed Active Mature rather than discontinued, which is unusual for a controller family this old.
| 1762-IQ8OW8 | 8 Point 24V DC Input / Relay Output Module | IN STOCK |
| 1762-IR4 | 4 Channel RTD / Resistance Input Module | IN STOCK |
| 1762-OW8 | 8 Point VAC/VDC Relay Output Module | IN STOCK |
| 1762-OA8 | 8 Point 120/240V AC Output Module | IN STOCK |
| 1762-OB8 | 8 Point 24V DC Source Output Module | IN STOCK |
| 1762-OB32T | 32 Point 24V DC Source Output Module | IN STOCK |
| 1762-IQ32T | 32 Point 24V DC Sink/Source Input Module | IN STOCK |
| 1762-IF4 | 4 Channel Current/Voltage Analog Input Module | IN STOCK |
| 1762-IQ8 | 8 Point 24V DC Sink/Source Input Module | IN STOCK |
| 1762-IA8 | 8 Point 120V AC Input Module | IN STOCK |
| 1762-OX6I | 6 Point 24V DC Isolated High Current Relay Output Module | IN STOCK |
| 1762-OV32T | 32 Point 24V DC Sink Output Module | IN STOCK |
| 1762-OB16 | 16 Point 24V DC Source Output Module | IN STOCK |
| 1762-OF4 | 4 Channel Analog Output Module | IN STOCK |
| 1762-IT4 | 4 Channel Thermocouple/mV Input Module | IN STOCK |
Catalog number |
1762-IQ8 |
Description |
8 Point 24V DC Sink/Source Input Module |
Channels |
8 dc inputs |
Class |
Expansion I/O module, MicroLogix 1200 / 1500 system |
Bus power |
+5V dc and +24V dc from the system power supply |
Dimensions |
90 mm high (110 mm with mounting tabs), 87 mm deep, 40 mm wide |
Shipping weight |
260 g with carton |
Heat dissipation |
3.7 W |
Power supply distance |
6 modules maximum from the supply |
Operating temperature |
0…55 °C |
Storage temperature |
-40…85 °C |
Humidity |
5…95 %, non-condensing |
Vibration |
10…500 Hz, 5 g |
Shock |
30 g operating |
Lifecycle status |
Active Mature |
UPC |
612598207206 |
Estimated lead time |
5 days |
Publication |
1762-UM003 |
Same-family catalog numbers: 1762-IQ8OW8, 1762-IQ32T. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1762 family.
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1762-UM003 (module specifications) and 1761-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
8 dc inputs on the 8 point 24v dc sink/source input module.
The module is a bus device: it takes +5V dc and +24V dc from the controller supply, reports into the controller's input and output image, and is configured from the programming software rather than by switches. Analog modules are calibrated in software, not with potentiometers.
Every module draws from the same 5V and 24V budget. Heat dissipation for this module is 3.7 W, which is the number to add to the controller figure when the enclosure is sized.
Power supply distance rating is six: a module may not sit more than six modules away from the system power supply. In a full six-module line that is automatically satisfied; in a longer line built on a 1500 system the placement has to be checked.
Current draw is published per module in the manual and has to be summed before the module count is frozen. Adding a seventh relay output module to a panel that is already at its 24V limit is the usual way an expansion goes wrong.
Dimensions are 90 mm high, 110 mm including mounting tabs, 87 mm deep and 40 mm wide, at 260 g shipping weight. Two M4 or #8 screws per module is the panel method; DIN rail works but panel mounting is preferred where vibration is present.
Operating temperature is 0…55 °C, storage -40…85 °C, humidity 5…95 % non-condensing, vibration 5 g over 10…500 Hz, shock 30 g. The module is UL 508 listed, C-UL certified and CE compliant, and rated Class I Division 2 for hazardous locations when installed per the manual.
Analog inputs and outputs are configured per channel: input range, filter frequency and data format. The default configuration is not necessarily the range the sensor uses, so a module that reads zero is often simply configured for the wrong range rather than faulty.
RTD and thermocouple modules need the sensor type set per channel as well. Recording the channel configuration in the panel documentation saves the next engineer a trip.
Lifecycle status on the Rockwell product page: Active Mature, with a published lead time of 5 days where the page lists one. That makes 1762 I/O a live spare line even though the controllers it plugs into are discontinued.
For a new machine the same functions exist in the Micro800 expansion range, but the modules are not interchangeable — different bus, different terminal base.
What does 1762-IQ8 provide?
8 Point 24V DC Sink/Source Input Module.
Which controllers accept 1762-IQ8?
MicroLogix 1200 and MicroLogix 1500 systems.
Is 1762-IQ8 still available from Rockwell?
Lifecycle status: Active Mature.
How much heat does 1762-IQ8 add?
3.7 W.
How far from the power supply can 1762-IQ8 sit?
Six modules maximum, the published distance rating.
The table lines up all fifteen thin 1762 expansion modules on the one number each of their pages prints that can be compared directly - heat dissipation in watts - together with the capacity and point count printed in the same field table.
| Catalog number | Capacity as printed | Points or channels | Printed heat | Heat per point |
| 1762-IQ32T | 32 dc inputs | 32 | 5.4 W | 0.169 W |
| 1762-IQ8OW8 | 4 dc inputs and 4 relay outputs | 8 | 4.4 W | 0.55 W |
| 1762-IQ8 | 8 dc inputs | 8 | 3.7 W | 0.46 W |
| 1762-OB32T | 32 sourcing dc outputs | 32 | 3.4 W | 0.106 W |
| 1762-OV32T | 32 sinking dc outputs | 32 | 3.4 W | 0.106 W |
| 1762-OA8 | 8 triac outputs | 8 | 2.9 W | 0.36 W |
| 1762-OB16 | 16 sourcing dc outputs | 16 | 2.9 W | 0.181 W |
| 1762-OW8 | 8 relay outputs | 8 | 2.9 W | 0.36 W |
| 1762-OX6I | 6 isolated relay outputs | 6 | 2.8 W | 0.47 W |
| 1762-IA8 | 8 ac inputs | 8 | 2 W | 0.25 W |
| 1762-IF4 | 4 analog input channels | 4 | 2 W | 0.50 W |
| 1762-OF4 | 4 analog output channels | 4 | 2 W | 0.50 W |
| 1762-OB8 | 8 sourcing dc outputs | 8 | 1.6 W | 0.20 W |
| 1762-IR4 | 4 RTD or resistance channels | 4 | 1.5 W | 0.38 W |
| 1762-IT4 | 4 thermocouple or mV channels | 4 | 1.5 W | 0.38 W |
Where this module sits: it prints 3.7 W for its 8 dc inputs, which is heat level 7 of 9 among the fifteen 1762 expansion modules. No other module in the family prints this exact figure. The level above it is 4.4 W on the 1762-IQ8OW8, 1.19 times this figure. The level below is 3.4 W on the 1762-OV32T, which is 1.09 times lighter. This page prints its capacity as "8 dc inputs".
Six slots filled with this module would radiate 22.2 W inside the enclosure; the same six slots filled with the 1762-IT4 or 1762-IR4 at 1.5 W would radiate 9.0 W. Both arrangements pass the printed rule, because the rule is counted in modules and not in watts: every page in this family prints the same "6 modules maximum from the supply" line. What the rule protects is the bus; what the enclosure has to absorb is the sum above, and only the first of the two is printed here.
The useful reading of this table is that geometry never varies inside the family - every one of the fifteen pages prints the same 90 mm height (110 mm with the mounting tabs), 87 mm depth and 40 mm width - so the six-module rule is always 240 mm of rail, and the only thing that changes from module to module is heat.
What the printed data does not carry: none of these fifteen pages prints the +5 V dc or +24 V dc current this module draws from the system power supply, none prints inrush, and none prints the supply budget of the controller the module hangs on. The printed heat is therefore the only load figure available here, and a bus budget cannot be closed from it.
Source: the field tables printed on the fifteen 1762 product pages on this site (catalog number, capacity, heat dissipation, dimensions, power supply distance) and Rockwell publication 1762-UM003, cited on each of those pages; no figure in this table is calculated or estimated.
The Allen-Bradley MicroLogix 1200 1762 controllers category lists the related catalog numbers, options and accessories for this range.