|
Product Details:
Payment & Shipping Terms:
|
1764-RPLCDR1 appears on the Rockwell product page only as a 'MicroLogix replacement part' — that is the whole published description, with no further definition of what the part physically is.
It is listed here because it exists in the catalogue and because people search for it by number; the page states what is published and nothing more.
| 1764-24AWA | Base, 12 ac inputs, 12 relay outputs, ac power | IN STOCK |
| 1764-28BXB1 | Base, 28 point, 24V dc, relay + FET | IN STOCK |
| 1764-LSP | Standard processor, 7.6 KB | IN STOCK |
| 1764-DAT | Data access tool | IN STOCK |
| 1764-MM1 | Memory module, 8K | IN STOCK |
| 1764-MM2 | Memory module, 16K | IN STOCK |
| 1764-MM3 | Memory module, 16K plus recipe data | IN STOCK |
| 1764-MM1RTC | 8K memory with real-time clock | IN STOCK |
| 1764-MM2RTC | 16K memory with real-time clock | IN STOCK |
| 1764-MM3RTC | 16K memory with real-time clock and recipe data | IN STOCK |
| 1764-RTC | Real-time clock | IN STOCK |
| 1764-RPLTB1 | Replacement part | IN STOCK |
| 1764-RPLTB2 | Replacement part | IN STOCK |
| 1764-RPLCDR1 | Replacement part | IN STOCK |
Catalog number |
1764-RPLCDR1 |
Description |
MicroLogix replacement part |
Used with |
MicroLogix 1500 system |
Lifecycle status |
Discontinued June 30, 2017 |
Replacement category |
No planned RA replacement |
UPC |
611320067996 |
Warranty |
1 year standard |
Publication |
1764-UM001 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1764-UM001 (module specifications) and 1764-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Catalog number, description 'MicroLogix replacement part', lifecycle status Discontinued June 30, 2017, replacement category No planned RA replacement, UPC 611320067996, and a 1 year standard warranty.
No dimension, material, fit or function is published. Anything beyond that would be inference, so this page does not carry it.
Confirm the part against the assembly it came from — take the number off the failed item's label rather than from a bill of materials that may predate revisions.
Ask for a photograph of the actual unit. For a part this thinly documented, the photo is the specification.
Discontinued June 30, 2017, and unlike the base units this replacement part has no successor category at all.
Supply is secondary market only. Price therefore reflects scarcity rather than any technical content.
Retired with the rest of the 1500 line on June 30, 2017, and carrying no successor — the usual end state for a replacement part.
For a line that has to keep running, the alternative to chasing a documented-thin spare is a planned migration — and that decision is usually cheaper made before the failure, not after.
1764-24AWA and 1764-28BXB1 base units, 1764-LSP and 1764-LRP processors, 1764-DAT and the MM-series memory modules cover the rest of the MicroLogix 1500 system.
The 1762 Compact I/O expansion range is the I/O that mounts to the right of these bases.
What is 1764-RPLCDR1?
A MicroLogix replacement part. Rockwell publishes no further definition for this catalog number.
Is 1764-RPLCDR1 still available from Rockwell?
No. Discontinued June 30, 2017; No planned RA replacement.
What does 1764-RPLCDR1 fit?
A MicroLogix 1500 system — confirm against the failed part's label.
Can you supply technical data for 1764-RPLCDR1?
Only what Rockwell publishes: catalogue identity, lifecycle and UPC.
Why is 1764-RPLCDR1 listed without specifications?
Because no specification is published, and inventing one would be worse than the gap.
1764-RPLCDR1 is a replacement door kit in the MicroLogix 1500 system. The controller is assembled from a 1764 processor and a 1764 base unit, with the memory module and the optional display device as separate line items, and Compact I/O 1769 modules as expansion.
| Attribute | Value |
| Catalog number | 1764-RPLCDR1 |
| Product type | replacement door kit |
| Family | MicroLogix 1500, bulletin 1764 |
| Function | Replacement door for the MicroLogix 1500 base unit |
| Access note | The processor door has to be removed to reach the communications toggle push button |
| Use | Mechanical replacement part, not an electrical accessory |
The rows above are the published values for this part, and they are the ones that decide whether it fits: a memory size against the program, a current draw against the base unit budget, and a series letter against the expansion the machine needs.
The memory module ladder is easy to mis-order: 1764-MM1 is 8K, 1764-MM2 and 1764-MM3 are 16K, and the RTC suffix adds a real-time clock on the same module. For a 1764-LRP program larger than 8K the published instruction is to use 1764-MM2 or 1764-MM2RTC, and the 1764-MM3 parts differ only by being able to store recipe data from the Data Log Queue.
Expansion is bounded by current, not by slot count alone: the base unit expansion budget is 2,250 mA at 5V dc with 400 mA at 24V dc, and each additional bank needs a 1769 power supply, a 1769-CRL or -CRR cable and a 1769-ECL or -ECR end cap. Without the end cap the bank is not a valid configuration, which is a detail that shows up only when the system is powered.
Firmware series decides capability, not just version: series C at FRN 6 adds floating point files, programmable limit switch, recipe instructions and message support for the 1769-SDN, and the 16 module bank requires a series C processor, a series B base unit, FRN 6 and RSLogix 500 version 5.10.00 or later. A used controller of the right catalog number but an older series will not reach that configuration.
Modbus RTU slave is a series B and later capability: the protocol maps coils, contacts, input registers and status words into MicroLogix data files, with four ranges mappable and three Modbus ranges fixed to the status file. A series A processor cannot be turned into a Modbus slave by configuration alone.
Before ordering, confirm the processor series and firmware release against the expansion the machine needs, confirm the memory module size against the actual program, and confirm the current budget of the base unit expansion against the modules already selected.
The Allen-Bradley MicroLogix 1500 1764 controllers category lists the related catalog numbers, options and accessories for this range.