1764-MM2 is a 16K memory module for the MicroLogix 1500: 16K of user memory, no clock.
Its job is transport and recovery — the program goes onto the module at the panel and comes back onto a replacement processor without a laptop.
| 1764-24AWA | Base, 12 ac inputs, 12 relay outputs, ac power | IN STOCK |
| 1764-28BXB1 | Base, 28 point, 24V dc, relay + FET | IN STOCK |
| 1764-LSP | Standard processor, 7.6 KB | IN STOCK |
| 1764-DAT | Data access tool | IN STOCK |
| 1764-MM1 | Memory module, 8K | IN STOCK |
| 1764-MM2 | Memory module, 16K | IN STOCK |
| 1764-MM3 | Memory module, 16K plus recipe data | IN STOCK |
| 1764-MM1RTC | 8K memory with real-time clock | IN STOCK |
| 1764-MM2RTC | 16K memory with real-time clock | IN STOCK |
| 1764-MM3RTC | 16K memory with real-time clock and recipe data | IN STOCK |
| 1764-RTC | Real-time clock | IN STOCK |
| 1764-RPLTB1 | Replacement part | IN STOCK |
| 1764-RPLTB2 | Replacement part | IN STOCK |
| 1764-RPLCDR1 | Replacement part | IN STOCK |
Catalog number |
1764-MM2 |
Description |
MicroLogix 1500 memory module |
Memory size |
16K |
Real-time clock |
Not included |
Programs held |
One user program at a time |
Fits |
1764-LSP or 1764-LRP processor option slot |
Lifecycle status |
Discontinued June 30, 2017 |
Replacement category |
No planned RA replacement |
UPC |
611320238037 |
Warranty |
1 year standard |
Publication |
1764-UM001 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1764-UM001 (module specifications) and 1764-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
16K of user memory. The module stores one program at a time; the controller's RUN LED flashes during transfer.
Without an RTC module the controller has no time base, so timestamped fault records are not available.
8K modules suit the 1764-LSP and its 8K program limit. Programs above 8K need the enhanced 1764-LRP and a 16K module.
There is no functional difference between this module and the MM3 equivalent unless the program writes recipe data to the Data Log Queue.
The module goes into the processor option slot and is loaded or stored from the programming software. It shares that slot with 1764-RTC and 1764-DAT — one device at a time.
Power down before fitting. The connector pins are exposed the moment the cover comes off, and a module fitted with the controller live is how processors get killed.
Discontinued June 30, 2017, replacement category No planned RA replacement. The whole MicroLogix 1500 line was retired in 2017.
Modules are consumable-grade hardware: limited write cycles, easily bent pins, and no way to test them without a working processor.
1764-RTC is the clock-only module; 1764-MM1/MM2/MM3 are the memory-only versions of the same part.
1764-LSP and 1764-LRP processors, 1764-24AWA and 1764-28BXB1 base units.
How much memory does 1764-MM2 hold?
16K of user memory.
Does 1764-MM2 include a real-time clock?
No.
Is 1764-MM2 still available from Rockwell?
No. Discontinued June 30, 2017; No planned RA replacement.
Can 1764-MM2 store more than one program?
No — one user program at a time.
Does 1764-MM2 fit the 1764-LSP?
Yes, in the processor option slot.
1764-MM2 is a 16K memory module in the MicroLogix 1500 system. The controller is assembled from a 1764 processor and a 1764 base unit, with the memory module and the optional display device as separate line items, and Compact I/O 1769 modules as expansion.
| Attribute | Value |
| Catalog number | 1764-MM2 |
| Product type | 16K memory module |
| Family | MicroLogix 1500, bulletin 1764 |
| Memory | 16K user memory |
| Module type | Memory module without real-time clock |
| With clock | 1764-MM2RTC, same 16K memory with a real-time clock |
| Selection rule | The 16K part is the minimum for a 1764-LRP program larger than 8K |
| Sibling | 1764-MM3 has the same user memory and adds recipe data storage from the Data Log Queue |
The rows above are the published values for this part, and they are the ones that decide whether it fits: a memory size against the program, a current draw against the base unit budget, and a series letter against the expansion the machine needs.
The default communication state is a commissioning tool rather than a setting: DF1 full-duplex defaults to 19.2K, no parity, node 1, no handshaking, CRC, one stop bit, and the communications toggle push button on the processor switches between that default and the user configuration, with the DCOMM LED showing which is active. That is how a controller with an unknown baud rate is recovered in the field.
Modbus RTU slave is a series B and later capability: the protocol maps coils, contacts, input registers and status words into MicroLogix data files, with four ranges mappable and three Modbus ranges fixed to the status file. A series A processor cannot be turned into a Modbus slave by configuration alone.
The memory module ladder is easy to mis-order: 1764-MM1 is 8K, 1764-MM2 and 1764-MM3 are 16K, and the RTC suffix adds a real-time clock on the same module. For a 1764-LRP program larger than 8K the published instruction is to use 1764-MM2 or 1764-MM2RTC, and the 1764-MM3 parts differ only by being able to store recipe data from the Data Log Queue.
Power supply distance rating is the other planning limit: an I/O module may sit at most 8 modules from its power supply on most modules, and only 4 for the 1769-HSC and the 1769-SDN. A 16 module bank built without regard to that rating powers up and then behaves unpredictably at the far end.
Before ordering, confirm the processor series and firmware release against the expansion the machine needs, confirm the memory module size against the actual program, and confirm the current budget of the base unit expansion against the modules already selected.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley MicroLogix 1500 1764 controllers category.