Product Details:
Payment & Shipping Terms:
|
1764-24AWA is a MicroLogix 1500 base unit: the I/O and power half of a controller that only becomes a PLC when a 1764-LSP processor is fitted on top.
That two-piece construction is the reason the base keeps turning up in spares lists years after the line was retired — a base with a dead processor can be brought back with a processor alone, and vice versa.
| 1764-24AWA | Base, 12 ac inputs, 12 relay outputs, ac power | IN STOCK |
| 1764-28BXB1 | Base, 28 point, 24V dc, relay + FET | IN STOCK |
| 1764-LSP | Standard processor, 7.6 KB | IN STOCK |
| 1764-DAT | Data access tool | IN STOCK |
| 1764-MM1 | Memory module, 8K | IN STOCK |
| 1764-MM2 | Memory module, 16K | IN STOCK |
| 1764-MM3 | Memory module, 16K plus recipe data | IN STOCK |
| 1764-MM1RTC | 8K memory with real-time clock | IN STOCK |
| 1764-MM2RTC | 16K memory with real-time clock | IN STOCK |
| 1764-MM3RTC | 16K memory with real-time clock and recipe data | IN STOCK |
| 1764-RTC | Real-time clock | IN STOCK |
| 1764-RPLTB1 | Replacement part | IN STOCK |
| 1764-RPLTB2 | Replacement part | IN STOCK |
| 1764-RPLCDR1 | Replacement part | IN STOCK |
Catalog number |
1764-24AWA |
Description |
MicroLogix 1500 base, 120V ac in / relay out / ac power |
Line power |
120/240V ac |
Inputs |
12 inputs, 120V ac |
Outputs |
12 relay outputs, 2 isolated relays per unit |
Total load limit |
1440 VA break |
Dimensions |
118 mm high (138 mm with DIN latch open), 168 mm wide, 87 mm deep |
Relay contact rating |
240V ac 7.5 A make / 0.75 A break, 120V ac 15 A make / 1.5 A break |
Continuous relay current |
8 A per common; 24 A at 150V, 20 A at 240V per controller |
Heat dissipation |
18 W + (0.3 x system loading) |
Mounting |
Horizontal, Compact I/O expansion to the right, 50 mm free space all round |
Lifecycle status |
Discontinued June 30, 2017 |
Replacement category |
Functional Replacement |
UPC |
611320023602 |
Publication |
1764-UM001 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1764-UM001 (module specifications) and 1764-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
12 inputs, 120V ac on the 120/240V ac line power.
12 relay outputs, 2 isolated relays per unit
Two relays on the base are isolated from the rest, which lets one contact switch a different circuit potential without a separate interposing relay.
Relay contacts are rated 7.5 A make and 0.75 A break at 240V ac, 15 A make and 1.5 A break at 120V ac, 2.5 A continuous. The total load controlled by the base is limited to 1440 VA break.
Continuous relay current is 8 A per common; 24 A at 150V, 20 A at 240V per controller, and per-common grouping therefore matters when several outputs feed the same machine section.
18 W + (0.3 x system loading). A fully loaded base in a sealed enclosure is a real heat source — the 50 mm of free space on all sides is the minimum, not a target.
118 mm high with the DIN latch closed, 138 mm open, 168 mm wide, 87 mm deep.
The base is useless without a processor: 1764-LSP (7.6 KB, standard) or 1764-LRP (enhanced, RS-232 port). Only the LRP supports programs above 8K, which is why MM2/MM3 modules are specified with it.
Compact I/O expansion modules mount to the right of the base and draw from its backplane supply.
Discontinued June 30, 2017, replacement category Functional Replacement — Rockwell pointed customers at a successor family rather than a like-for-like part.
For a running line the practical path is a tested spare base, or a migration project. Mixing a used base with a used processor of unknown history is how a panel ends up with two faults instead of one.
What I/O does 1764-24AWA have?
12 inputs, 120V ac; 12 relay outputs, 2 isolated relays per unit.
What line power does 1764-24AWA take?
120/240V ac.
Is 1764-24AWA still available from Rockwell?
No. Discontinued June 30, 2017; replacement category Functional Replacement.
Does 1764-24AWA work without a processor?
No. It needs a 1764-LSP or 1764-LRP processor.
What is the relay rating on 1764-24AWA?
240V ac 7.5 A make / 0.75 A break, 2.5 A continuous, 1440 VA total load break.
1764-24AWA is a 24 point AC base unit in the MicroLogix 1500 system. The controller is assembled from a 1764 processor and a 1764 base unit, with the memory module and the optional display device as separate line items, and Compact I/O 1769 modules as expansion.
| Attribute | Value |
| Catalog number | 1764-24AWA |
| Product type | 24 point AC base unit |
| Family | MicroLogix 1500, bulletin 1764 |
| Points | 24 I/O points in the base unit |
| Base unit role | Carries the embedded I/O and the power supply for the processor |
| Series requirement | Series A supports 8 I/O modules, series B supports the 16 module bank with FRN 6 |
| Related base units | 1764-24BWA and 1764-28BXB |
| Output type | Relay and AC/DC combinations on the standard bases; FET outputs only on 1764-28BXB |
The rows above are the published values for this part, and they are the ones that decide whether it fits: a memory size against the program, a current draw against the base unit budget, and a series letter against the expansion the machine needs.
Expansion is bounded by current, not by slot count alone: the base unit expansion budget is 2,250 mA at 5V dc with 400 mA at 24V dc, and each additional bank needs a 1769 power supply, a 1769-CRL or -CRR cable and a 1769-ECL or -ECR end cap. Without the end cap the bank is not a valid configuration, which is a detail that shows up only when the system is powered.
Power supply distance rating is the other planning limit: an I/O module may sit at most 8 modules from its power supply on most modules, and only 4 for the 1769-HSC and the 1769-SDN. A 16 module bank built without regard to that rating powers up and then behaves unpredictably at the far end.
The default communication state is a commissioning tool rather than a setting: DF1 full-duplex defaults to 19.2K, no parity, node 1, no handshaking, CRC, one stop bit, and the communications toggle push button on the processor switches between that default and the user configuration, with the DCOMM LED showing which is active. That is how a controller with an unknown baud rate is recovered in the field.
MicroLogix 1500 is a two part controller rather than one catalog number: a processor (1764-LSP or the enhanced 1764-LRP with its second RS-232 port) plugs into a base unit that carries the embedded I/O and the supply. A quote that names only the processor is an incomplete quote, and a spare that names only the base unit is a controller that will not run.
Before ordering, confirm the processor series and firmware release against the expansion the machine needs, confirm the memory module size against the actual program, and confirm the current budget of the base unit expansion against the modules already selected.
This part sits in the Allen-Bradley MicroLogix 1500 1764 controllers category, with the other models and spare parts listed alongside it.