Product Details:
Payment & Shipping Terms:
|
1785-L80B is a 1785-L80B Rockwell PLC-5/80 Processor. It carries 100 K words of user memory and drives up to 3072 (any mix) or 3072 in + 3072 out discrete points, which is the number that decides whether a line can stay on this platform or has to be migrated.
The controller mounts in the leftmost slot of a 1771 chassis and takes rack 0. The published capacity is 24 (0-27) racks and 93 chassis in total, which includes the rack the controller itself occupies.
| 1785-ACC5LA | PLC-5 accessory kit | IN STOCK |
| 1785-ACC5LB | PLC-5 accessory kit | IN STOCK |
| 1785-CHBM | ControlNet backup cartridge | IN STOCK |
| 1785-ENET | PLC-5 Ethernet interface module | IN STOCK |
| 1785-L26B | PLC-5/26 protected processor, 16 K words | IN STOCK |
| 1785-L40C15 | PLC-5 ControlNet 1.5 processor, 48 K words | IN STOCK |
| 1785-L40C | PLC-5 ControlNet 1.25 processor, 48 K words | IN STOCK |
| 1785-L46C15 | PLC-5/46C ControlNet 1.5 protected processor | IN STOCK |
| 1785-L40E | PLC-5/40E Ethernet processor, 48 K words | IN STOCK |
| 1785-L60B | PLC-5/60 processor, 64 K words | IN STOCK |
| 1785-L60L | PLC-5/60L processor with extended local I/O | IN STOCK |
| 1785-L80C | PLC-5 ControlNet 1.25 processor, 100 K words | IN STOCK |
| 1785-L80B | PLC-5/80 processor, 100 K words | IN STOCK |
| 1785-L80C15 | PLC-5 ControlNet 1.5 processor, 100 K words | IN STOCK |
| 1785-L80E | PLC-5/80E Ethernet processor, 100 K words | IN STOCK |
| 1785-L86B | PLC-5/86 protected processor, 100 K words | IN STOCK |
| 1785-M100 | 100 K word memory module | IN STOCK |
| 1785-ME16 | 16 K word EEPROM memory cartridge | IN STOCK |
| 1785-ME32 | 32 K word EEPROM memory cartridge | IN STOCK |
| 1785-ME64 | 64 K word EEPROM memory cartridge | IN STOCK |
| 1785-RC | Relay cartridge, edit and force monitoring | IN STOCK |
Catalog number |
1785-L80B |
Product type |
PLC-5 programmable controller |
Processor |
1785-L80B Rockwell PLC-5/80 Processor |
Maximum user memory |
100 K words |
Total I/O, any mix |
3072 (any mix) or 3072 in + 3072 out |
Communication ports |
4 DH+/Remote I/O (adapter or scanner), 1 serial port configurable for RS-232/423 and RS-422A |
Maximum I/O racks |
24 (0-27) |
Maximum I/O chassis |
93 |
Lifecycle status |
Discontinued |
Discontinued date |
31 July 2017 |
Replacement category |
Engineering Replacement |
UPC |
612598126125 |
Country of origin |
United States of America |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1785-UM012 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
1785-L80B is a 1785-L80B Rockwell PLC-5/80 Processor. It carries 100 K words of user memory and drives up to 3072 (any mix) or 3072 in + 3072 out discrete points, which is the number that decides whether a line can stay on this platform or has to be migrated.
Communication is fixed in hardware on this model: 4 DH+/Remote I/O (adapter or scanner), 1 serial port configurable for RS-232/423 and RS-422A. There is no slot to add a different network card later, so the network you plan around is the network you buy.
The controller mounts in the leftmost slot of a 1771 chassis and takes rack 0. The published capacity is 24 (0-27) racks and 93 chassis in total, which includes the rack the controller itself occupies.
Wiring is by the standard PLC-5 terminal blocks and battery assembly; the processor keeps its program in RAM with battery backup, so the battery condition is the first thing to check on any unit pulled from a panel.
A /80 has 64 K words of total data table space, with a 56 K word limit per program file and 32 K words per data table file.
Rockwell lists 1785-L80B as Discontinued with a replacement category of Engineering Replacement.
The published discontinued date is 31 July 2017.
The processor family was wound down through the 2010s, so the practical replacement path is a Logix migration rather than a drop-in card. That means the ladder has to be re-hosted, and every 1771 rack in the cell has to be re-thought, not just the CPU.
These processors survive where a line was never re-engineered: water treatment, cement, pulp and paper, older automotive press lines and packaging machines with 1771 racks still in service.
The common failure pattern is not the CPU logic but the battery, the power supply and the backplane connectors, which is why buyers usually want a spare processor of the same catalog number rather than a rebuilt one.
Ask for the series and firmware revision printed on the label, and for a photo of the battery date code. A unit that has sat unpowered for years may still be fine, but a leaking battery will have corroded the board.
Confirm the catalog number exactly. The suffix matters: a /40E is not a /40B, and a ControlNet 1.5 processor will not run a program written for a 1.25 unit without a firmware review.
What is the memory and I/O capacity of 1785-L80B?
100 K words of user memory and 3072 (any mix) or 3072 in + 3072 out total I/O, any mix, per the 1785-UM012 system table.
Is 1785-L80B still sold by Rockwell?
No. It is listed as Discontinued with replacement category Engineering Replacement.
What are the communication ports on 1785-L80B?
4 DH+/Remote I/O (adapter or scanner), 1 serial port configurable for RS-232/423 and RS-422A.
Can I use 1785-L80B with 1771 I/O racks?
Yes. It is designed for 1771 chassis, up to 24 (0-27) racks and 93 chassis per the published specification.
What should I check before buying a used 1785-L80B?
Series and firmware revision, battery condition and date code, and the exact catalog suffix.
This record is placed on the five-record 1785 PLC-5 processor ladder carried on this site. The table lines up the two things that actually vary between the records - the processor name with its network, and the user memory - against the lifecycle and traceability each page prints, because the I/O ceiling and the rack limits are identical on all five and belong in the text rather than in a column.
| Catalog number | Processor as named | User memory | Network ports | Discontinued | UPC / country of origin |
| 1785-L86B | PLC-5/86 Protected Processor | 100 K words | 4 DH+/Remote I/O (adapter or scanner), 1 serial RS-232/423 and RS-422A | not published | not published / not published |
| 1785-L80C15 | PLC-5 ControlNet 1.5 Processor | 100 K words | ControlNet channel, DH+/Remote I/O channels, 1 serial RS-232/423 and RS-422A | 31 July 2017 | 612598180394 / United States |
| 1785-L80B | PLC-5/80 Processor | 100 K words | 4 DH+/Remote I/O (adapter or scanner), 1 serial RS-232/423 and RS-422A | 31 July 2017 | 612598126125 / United States |
| 1785-L80C | PLC-5 ControlNet 1.25 Processor | 100 K words | ControlNet channel, DH+/Remote I/O channels, 1 serial RS-232/423 and RS-422A | 31 July 2017 | not published / not published |
| 1785-L60B | PLC-5/60 Processor | 64 K words | 4 DH+/Remote I/O (adapter or scanner), 1 serial RS-232/423 and RS-422A | 31 December 2015 | not published / not published |
Where this record sits: it is the DH+/Remote I/O member of the 100 K group, so it differs from 1785-L80C15 in the network ports and not in the memory, and it is one of only two records in the batch that print a UPC and a country of origin.
Four of the five records print the same 100 K words of user memory and the same 3072-point I/O ceiling, which means the catalog suffix is not doing the work a buyer might assume it does. What the letter changes is the network: the B records carry four DH+/Remote I/O channels that can each act as adapter or scanner plus one serial port, and the C records carry a ControlNet channel alongside DH+/Remote I/O channels. Memory is what separates 1785-L60B from the rest, and nothing else on the five pages does.
What these pages do not carry: no scan or program execution time, no power consumption or backplane load, no dimensions or weight, no battery or memory-backup detail beyond the stock list, no explanation of what the Protected designation protects in the 1785-L86B, no discontinuation date on that record, no replacement part number on any of the five, and no statement of which memory module or EEPROM cartridge each processor accepts.
This is the record to read for the plain PLC-5/80: four DH+/Remote I/O channels configurable as adapter or scanner, one serial port for RS-232/423 and RS-422A, 100 K words, and a UPC and country of origin where the ControlNet sibling 1785-L80C prints neither. Same memory, same withdrawal date, different traceability on the page.
Source: the product specification tables printed on the five 1785 records on this site, together with the PLC-5 stock list those pages carry; the processor names, memory figures, I/O ceilings, rack and chassis limits, network port descriptions, discontinuation dates, replacement categories, UPCs and countries of origin are quoted from the records that print them, and fields a record leaves out are shown as not published rather than filled in from a sibling.
This part sits in the Allen-Bradley PLC-5 systems and 1771 I/O category, with the other models and spare parts listed alongside it.