Product Details: |
20AC022F0AYNANC0 is a PowerFlex 70 in the 400 V class at the 22 A rating: 11 kW, 15 Hp, frame D.
Its build differs from the plain 20AC022A0AYNANC0 in flange mount. The power stage is the same across the family, so the differences are in the option slots only.
Quick answer. 20AC022F0AYNANC0 is a Rockwell Automation PowerFlex 70 drive, 400 V AC class, 22 A normal duty (11 kW / 15 Hp), frame D, F - Flange mount, front IP 20, rear heatsink IP 66.
| 20AC022F3NYNANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022F0AYNANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022C0AYNANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A3AYYADG1 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A3AYNANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A3AYNADC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A0AYNANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022C3AYYANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022C3AYNANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022C3AYNAEC1 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022C0NYNANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A3AYYANC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A3AYNANG0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A3AYNAEG0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A3AYNAEC0 | 22 A / 11 kW, frame D | IN STOCK |
| 20AC022A0AYYANC0 | 22 A / 11 kW, frame D | IN STOCK |
Catalog number |
20AC022F0AYNANC0 |
Voltage class |
400 V AC, 3-phase, 6-pulse |
Normal duty output current |
22 A |
Normal duty motor rating |
11 kW / 15 Hp |
Frame size |
D |
Enclosure (d) |
F - Flange mount, front IP 20, rear heatsink IP 66 |
HIM (e) |
0 - Blank cover |
Documentation (f) |
A - Manual included |
Brake IGBT (g) |
Y - Brake IGBT fitted |
Internal brake resistor (h) |
N - No internal brake resistor |
Emission class (i) |
A - Filtered |
Comm slot (j) |
N - None |
Control and I/O (k) |
C - Enhanced control, no safe-off |
Feedback (l) |
0 - No feedback, enhanced control |
Source |
20A-UM001 p.10 catalog explanation |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 20A-UM001 (Feb 2018) (module specifications) and 20A-TD001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The string is 20A (drive), C (400 V AC 3-phase), 022 (rating), then nine option positions d to l.
Here: d=F, e=0, f=A, g=Y, h=N, i=A, j=N, k=C, l=0.
Rockwell prints each position as its own table on page 10 of 20A-UM001; decoding by eye is where most used-drive listings go wrong.
Enclosure (d) decides the mounting: Flange mount, front IP 20, rear heatsink IP 66.
HIM (e): Blank cover. The LCD keypad is removable, so a used drive can arrive with a blank cover.
Brake IGBT (g): Brake IGBT fitted; internal brake resistor (h): No internal brake resistor. Both are needed before a holding brake can be wired straight to the drive.
Comm slot (j): None. Control and I/O (k): Enhanced control, no safe-off. Feedback (l): No feedback, enhanced control.
Normal duty 22 A, 11 kW / 15 Hp on frame D.
Frame sets the heatsink, fan and terminal spacing, so a frame change is also a panel-space change.
Heavy duty figures are lower than the normal duty row and are listed separately in 20A-UM001.
Nameplate catalog number, full 16 characters, against this page - one letter changes the enclosure or the network option.
Safe-off builds (k=G) carry a second terminal pair; a standard-control drive does not.
Encoder interface (l=1) is a separate board; it is not CE EMC certified when fitted.
Every code above is transcribed from the Catalog Number Explanation, page 10 of Rockwell publication 20A-UM001 (February 2018).
No field on this page is inferred from a distributor listing; positions Rockwell leaves blank are not published and are not shown as data.
What is 20AC022F0AYNANC0?
PowerFlex 70, 400 V, 22 A / 11 kW, frame D, flange mount.
What is the output current of 20AC022F0AYNANC0?
22 A normal duty at 400 V.
Which frame is 20AC022F0AYNANC0?
Frame D, 11 kW / 15 Hp normal duty.
Does 20AC022F0AYNANC0 have a network slot?
None.
What enclosure is 20AC022F0AYNANC0?
Flange mount, front IP 20, rear heatsink IP 66.
Related catalog numbers in the same rating code. Same 22 A A power stage, different option string - the enclosure, HIM, communication and safety positions are what change between them.
20AC022F3NYNANC0 (22 A / 11 kW, frame D) · 20AC022C0AYNANC0 (22 A / 11 kW, frame D) · 20AC022A3AYYADG1 (22 A / 11 kW, frame D) · 20AC022A3AYNANC0 (22 A / 11 kW, frame D) · 20AC022A3AYNADC0 (22 A / 11 kW, frame D) · 20AC022A0AYNANC0 (22 A / 11 kW, frame D) · 20AC022C3AYYANC0 (22 A / 11 kW, frame D) · 20AC022C3AYNANC0 (22 A / 11 kW, frame D) · 20AC022C3AYNAEC1 (22 A / 11 kW, frame D)