Product Details:
Payment & Shipping Terms:
|
20AC015A0AYNANC0 is a PowerFlex 70 in the 400 V class at the 15.4 A rating: 7.5 kW, 10 Hp, frame C.
This is the plain build of the 20AC015 rating: panel mount, filtered, no network slot. The power stage is the same across the family, so the differences are in the option slots only.
Quick answer. 20AC015A0AYNANC0 is a PowerFlex 70 drive, 400 V AC class, 15.4 A normal duty (7.5 kW / 10 Hp), frame C, A - Panel mount, IP 20, NEMA/UL Type 1.
| 20AC015C0AYNANC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYYANC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYYAEC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYNANC1 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYNANC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYNAEG0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYNAEC1 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYNAEC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYNADG1 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A0AYYANC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A0AYNANC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A0AYNAEC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A0AYNADG0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015F0AYNANC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015C3AYYANC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015C3AYNANC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYNADC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A3AYNACC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A0AYNANC1 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A0AYNADC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
| 20AC015A0AYNACC0 | 15.4 A / 7.5 kW, frame C | IN STOCK |
Catalog number |
20AC015A0AYNANC0 |
Voltage class |
400 V AC, 3-phase, 6-pulse |
Normal duty output current |
15.4 A |
Normal duty motor rating |
7.5 kW / 10 Hp |
Frame size |
C |
Enclosure (d) |
A - Panel mount, IP 20, NEMA/UL Type 1 |
HIM (e) |
0 - Blank cover |
Documentation (f) |
A - Manual included |
Brake IGBT (g) |
Y - Brake IGBT fitted |
Internal brake resistor (h) |
N - No internal brake resistor |
Emission class (i) |
A - Filtered |
Comm slot (j) |
N - None |
Control and I/O (k) |
C - Enhanced control, no safe-off |
Feedback (l) |
0 - No feedback, enhanced control |
Source |
20A-UM001 p.10 catalog explanation |
20AC015A0AYNANC0 (PowerFlex 70, 400 V class 3-phase, Frame C): 15.4 A continuous output at 400 V AC input, 7.5 kW / 10 HP normal duty and 5.5 kW / 7.5 HP heavy duty, drawing 15.1 A at 400 V AC. Option content: a blank cover instead of a Human Interface Module, no communication slot fitted, enhanced control (no Safe-Off); the enclosure is Panel Mount, IP 20 / NEMA-UL Type 1 and no internal brake resistor is fitted.
The normal-duty rating sets the motor size on a fan or pump; the heavy-duty rating is roughly one frame smaller and is the number to use on a constant-torque load, so one catalogue number covers two different motors depending on which duty the specification names. The drive stays inside a cabinet and relies on the panel for its Type 1 rating. Control is by hard-wired digital inputs and an analog reference only. Enhanced control adds the extended parameter files and the encoderless options, without the safety option. On a high-inertia load the drive will trip on bus overvoltage during deceleration unless a suitable external dynamic brake resistor is added and parameter 163 [DB Resistor Type] is set for it. Sizing values come from the 400 V three-phase rating and input protection table of Rockwell publication 20A-TD001; catalogue-number positions come from 20A-UM001. Digits after the control code are not interpreted here - match the nameplate before ordering a replacement.
Attribute values above for 20AC015A0AYNANC0 are reproduced from the manufacturer's product data. For the authoritative technical record see the PowerFlex 70 User Manual, publication 20A-UM001, and the PowerFlex 70 Technical Data, publication 20A-TD001; mounting and wiring are in the Installation Instructions, publication 20A-IN009. Certification details, with certificate and file numbers, are listed in the FAQ below.
The string is 20A (drive), C (400 V AC 3-phase), 015 (rating), then nine option positions d to l.
Here: d=A, e=0, f=A, g=Y, h=N, i=A, j=N, k=C, l=0.
Rockwell prints each position as its own table on page 10 of 20A-UM001; decoding by eye is where most used-drive listings go wrong.
Enclosure (d) decides the mounting: Panel mount, IP 20, NEMA/UL Type 1.
HIM (e): Blank cover. The LCD keypad is removable, so a used drive can arrive with a blank cover.
Brake IGBT (g): Brake IGBT fitted; internal brake resistor (h): No internal brake resistor. On 20AC015A0AYNANC0 the two characters are read together, because both are needed before a holding brake can be wired straight to the drive.
Comm slot (j): None. Control and I/O (k): Enhanced control, no safe-off. Feedback (l): No feedback, enhanced control.
Normal duty 15.4 A, 7.5 kW / 10 Hp on frame C.
Frame sets the heatsink, fan and terminal spacing, so a frame change is also a panel-space change.
What to verify before buying used Nameplate catalog number, full 16 characters, against this page - one letter of 20AC015A0AYNANC0 changes the enclosure or the network option.
Safe-off builds (k=G) carry a second terminal pair; a standard-control drive does not.
Encoder interface (l=1) is a separate board; it is not CE EMC certified when fitted.
Every code above is transcribed from the Catalog Number Explanation, page 10 of Rockwell publication 20A-UM001.
No field on this page is inferred from a distributor listing; positions Rockwell leaves blank are not published and are not shown as data.
What is 20AC015A0AYNANC0?
PowerFlex 70, 400 V, 15.4 A / 7.5 kW, frame C, panel mount.
What is the output current of 20AC015A0AYNANC0?
15.4 A normal duty at 400 V.
Which frame is 20AC015A0AYNANC0?
Frame C, 7.5 kW / 10 Hp normal duty.
Does 20AC015A0AYNANC0 have a network slot?
None.
What enclosure is 20AC015A0AYNANC0?
Panel mount, IP 20, NEMA/UL Type 1.
Related catalog numbers in the same rating code. Same 15.4 A A power stage, different option string - the enclosure, HIM, communication and safety positions are what change between them.
20AC015C0AYNANC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYYANC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYYAEC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNANC1 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNANC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNAEG0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNAEC1 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNAEC0 (15.4 A / 7.5 kW, frame C) · 20AC015A3AYNADG1 (15.4 A / 7.5 kW, frame C) · 20AC015A0AYYANC0 (15.4 A / 7.5 kW, frame C)
Browse the Allen-Bradley PowerFlex drives and motors category for the other models, options and spare parts that share this range.