This page documents catalog number 440G-T21BNPT-4B, a TLS-GD2 positive-mode tongue-operated guard locking switch in the TLS-1 range. It locks a machine guard closed until power is isolated and keeps the power isolated while the guard is open. The variant is power to release with escape release with position monitoring 2 N.C. and 1 N.O., 110 V ac solenoid supply, 1/2 inch NPT adaptor, and no actuator supplied. The figures below are quoted from the TLS-GD2 installation instructions and the published selection data.
| Field | Value |
| Standards | ISO 14119, IEC 60947-5-1 |
| Safety classification | Type 2 interlocking device with guard locking and low coding (tongue) per ISO 14119 |
| Holding force Fmax | plastic pins 1,950 N (488 lbf), steel bolts 2,600 N (585 lbf) |
| Holding force Fzh | plastic pins 1,500 N (337 lbf), steel bolts 2,000 N (450 lbf) |
| Releasable load | 100 N (22.5 lbf) maximum |
| Solenoid power | 7 W typical at 100 percent duty |
| Escape release button | 50 N (11.25 lbf) maximum force |
| Thermal current | 10 A; rated insulation voltage 500 V |
| Switching | A600 AC-15 at 600 V and 1.2 A, DC-13 at 24 V and 2 A, minimum 3 mA at 18 V dc |
| Actuation | 160 mm/s maximum, 100 mm/min minimum, 1 cycle per second, radius 160 mm or 80 mm with the flexible actuator |
| Mechanical life | 1,000,000 operations |
| Enclosure | IP66, IP67 and IP69K, with IP rated glands required for IP69K |
| Temperature | minus 20 to plus 60 C |
| Weight | 400 g (0.88 lb), red glass-filled PBT housing, stainless steel actuator |
| Torque | mounting bolts 1.4 N m, lid screws 1.2 N m, terminal screws 1.02 N m |
| Attribute | Value |
| Type | TLS-1 |
| Locking principle | power to release with escape release |
| Safety contacts | 3 N.C. direct opening action |
| Auxiliary contacts | 2 N.O., one used for solenoid monitoring |
| Solenoid supply | 110 V ac |
| Actuator | no actuator supplied |
| Entry | 1/2 inch NPT adaptor |
Functional safety. The family data sheet gives B10d above 2 million operations at minimum load, PFHD below 3 x 10^-7 and MTTFd above 385 years, on the stated assumption of a usage rate of 10 operations per 10 minutes, 24 hours a day, 360 days a year. PLe or PLd and SIL 2 or SIL 3 are described as possible depending on architecture, so the switch is a component of the performance level rather than a guarantee of it.
Rotatable head. The head has two entry slots and rotates to give four actuator entry points, with a blanking plug for the unused slot. That is a real installation freedom, and it also means the slot that is not used must be plugged, because an open unused slot is an invitation to a second actuator and the publication warns that spare actuators compromise the integrity of the safety system.
Power to lock caution. Where a switch is power to lock, the published warning is that provisions may be required so that a dangerous situation cannot result from an open circuit fault or a power cut. A power-to-lock guard stays locked when the supply fails, which is the reverse of the assumption most operators make about a guard.
Sliding bolt. The sliding bolt actuator 440G-A27163 is published as not to be used with the escape release. That is a mechanical conflict rather than a preference: the bolt occupies the space the release needs, and a guard that needs both full body access and a sliding bolt has to be solved with a different interlock arrangement.
| Parameter | Value |
| Dimensions with base | 120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters |
| Enclosure rating | Meets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one |
| Operating temperature | -20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock |
| Storage temperature | -40 to 85 degrees C (-40 to 185 degrees F) |
| Relative humidity | 5 to 95 percent non-condensing, IEC 60068-2-30 damp heat |
| Shock and vibration | Operating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating |
| Isolation | 50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s |
| ESD and RF immunity | 6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz |
| Transient immunity | Plus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge |
| Emissions | CISPR 11 Group 1 Class A |
| Mounting | Mounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole |
| Weight | 0.29 kg (0.64 lb) with base |
| Field power bus | 24 V dc nominal, 10 to 28.8 V dc range |
| PointBus current | 75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23 |
Connector shells are the part of the ordering decision a drawing rarely shows. M8 is a single-pin pico shell, M12 is a four or five pin micro shell, M23 is a twelve pin shell, and the same channel count can be delivered in three different shell sizes with three different cable preparations. A plant that standardises on M12 cord sets buys the M12 variant; a plant that already runs M8 patch cables buys the M8 variant and gets the same eight channels in eight single-pin shells, and the field wiring effort differs accordingly.
Every module in this family carries a green and red module-status indicator, a network-status indicator and per-channel yellow or red status, all on the logic side, so a technician diagnoses a channel from the face of the module rather than from a wiring diagram.
What this page does not claim matters as much as what it does. It does not state a performance level for a machine, a guard cycle count, or a wire length beyond the published cordsets, because those follow from the application; only what the source publications state is printed here.
No lifecycle statement and no price is implied. The contact, solenoid and environmental figures are quoted from the TLS-GD2 installation instructions, and a figure absent from this page is absent from those publications for this catalog number.