Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12

China Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier
Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12 supplier

Large Image :  Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley ArmorPoint 1738-IR2M12 / 1738IR2M12

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $181.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1738-IR2M12

This page documents the 1738-IR2M12, a 2-channel RTD input, M12 connectors in the ArmorPoint I/O family. The supported sensor list, resolution, update rate and cold-junction behaviour are quoted from the RTD and thermocouple input module installation instructions.

Published module data

FieldValue
Catalog number1738-IR2M12
Family1738 ArmorPoint I/O, temperature input
Channels2 single-ended, non-isolated
ConnectorsM12 (micro), 2 connectors
Input range0 to 600 ohm
Resolution16 bits, 9.5 mV per count and 0.03 degrees C per count on a Pt 385 sensor at 25 degrees C
Accuracy0.1 percent of full scale at 25 degrees C, 30 ppm per degree C drift, with offset, gain, non-linearity and repeatability included
ConverterDelta Sigma, 120 dB common mode rejection, 100 dB normal mode rejection
Keyswitch position6
PointBus current220 mA at 5 V dc
Power dissipation1.0 W maximum (3.3 BTU/hr)
Isolation50 V rms, tested at 1,000 V rms for 1 s; no input protection, so an RTD lead that sees a supply is a damaged channel
Data size6 bytes produced, 0 consumed

Sensors supported and the range each one covers

The sensor list decides the application, and this module publishes it with a usable range for every sensor type: 100 ohm Pt alpha 0.00385 (-200 to 870 C), 200 ohm Pt alpha 0.00385 (-200 to 630 C), 100 ohm Pt alpha 0.003916 (-200 to 630 C), 200 ohm Pt alpha 0.003916 (-200 to 630 C), 10 ohm Cu alpha 0.00427 (-200 to 260 C), 100 ohm Ni alpha 0.00618 (-60 to 250 C), 120 ohm Ni alpha 0.00672 (-60 to 250 C) and 120 ohm Ni alpha 0.00618 (-60 to 250 C).

A catalog number that supports one curve is a spare part; a module carrying this list is the channel a plant standardises on when one area already runs Pt 100 and another runs Ni 120. The list is also the reason a substitution between temperature modules has to be checked curve by curve rather than by channel count.

Update rate, step response and the notch setting

Update rate follows the notch chosen for the line frequency: 40 ms at a 50 Hz notch, 33 ms at 60 Hz (default), 20 ms at 100 Hz, 17 ms at 120 Hz, 10 ms at 200 Hz, 8 ms at 240 Hz, 7 ms at 300 Hz, 5 ms at 400 Hz and 4 ms at 480 Hz. Step response is 60 ms at 50 Hz, 50 ms at 60 Hz, 30 ms at 100 Hz, 25 ms at 120 Hz, 15 ms at 200 Hz, 13 ms at 240 Hz, 10 ms at 300 Hz, 8 ms at 400 Hz and 6 ms at 480 Hz, so the module settles faster as the notch moves up the ladder, and a slow reading at 50 Hz is a setting rather than a fault.

Data size is 6 bytes produced, 0 consumed, and the isolation figure is 50 V rms, tested at 1,000 V rms for 1 s; no input protection, so an RTD lead that sees a supply is a damaged channel. Note the absence of input protection: a sensor lead that sees a supply is a damaged channel rather than a recoverable fault, so field wiring on a temperature block is checked before power is applied.

Environment and installation facts that repeat across the family

ParameterValue
Dimensions with base120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters
Enclosure ratingMeets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one
Operating temperature-20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock
Storage temperature-40 to 85 degrees C (-40 to 185 degrees F)
Relative humidity5 to 95 percent non-condensing, IEC 60068-2-30 damp heat
Shock and vibrationOperating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating
Isolation50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s
ESD and RF immunity6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz
Transient immunityPlus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge
EmissionsCISPR 11 Group 1 Class A
MountingMounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole
Weight0.29 kg (0.64 lb) with base
Field power bus24 V dc nominal, 10 to 28.8 V dc range
PointBus current75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23

Mounting is part of the electrical path: the module sits on a base, the base is fixed to a grounded metal plate with #8 (M4) screws, and the ground lug is also a mounting hole. The conductive path therefore runs through the base and the plate rather than through the module, which is why a module swapped onto a dirty base measures as a missing earth and reads like an electronics fault.

The family is built so the module is the replaceable unit and the base stays on the machine. The keyswitch position on the base has to match the module class, and a module inserted one position off is not a wiring error that can be traced with a meter but a mapping error that appears as shifted channels. That is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, only the position and the adapter map.

The adapter is the only place the channel map exists. Modules publish channel counts and data bytes; the adapter publishes the order in which those bytes appear to a scanner, so a replacement module in the same position needs no map change while a module moved to a new position does.

A sealed block is not a substitute for a cabinet when the environment includes washdown or corrosive atmosphere. The IP rating covers the module and its mated connectors; it says nothing about the chemical resistance of the shell or the cable jacket.

A backplane in this family is commissioned in the order of the bases rather than by the wiring, and that is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, so the channel number a technician sees on the module face is derived from the position on the backplane and the mapping in the adapter. A module inserted one position off is not a wiring error that can be traced with a meter; it is a mapping error that appears as shifted channels.

The default data map matters as much as the rating: a digital module produces one byte and, for outputs, consumes one, and that byte is the channel status and output state the controller actually sees.

What this page does not claim matters as much as what it does. It states no cycle time, no maximum cable length and no network baud rate for this catalog number, because those belong to the segment and the adapter rather than to the module, and a figure of that kind copied into a page becomes a specification nobody can trace back to a publication. Where the source documents do fix a value - the channel count, the shell, the current limit, the isolation rating, the temperature window, the data size - it is on this page with the publication named.

No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions (1738-IN001 for dc outputs, 1738-IN002 for dc inputs, 1738-IN003 for analog inputs and the temperature input instructions) and the DeviceNet adapter user manual 1738-UM001.

Related catalog numbers in the 1738 range

This page links twelve of the 42 1738 records on this site; the closest rating codes come first. This page is 1738-IR2M12.

For the surrounding range, open the Allen Bradley Other PLC catalogue index — 1738-IR2M12 is listed there beside the rest of the other-PLC group. The index sits one level above this page in the site tree.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)