This page documents the 1738-IB8M8, a 8-channel sinking dc input, M8 connectors in the ArmorPoint I/O family: a sealed IP67 block that mounts on a base spanning two backplane positions and needs no cabinet of its own. Channel count, thresholds, delay and dissipation below are taken from the module installation instructions, which is the document that fixes them per catalog number.
| Field | Value |
| Catalog number | 1738-IB8M8 |
| Family | 1738 ArmorPoint I/O, 24 V dc digital input |
| Channels | 8 (1 group of 8), non-isolated, sinking |
| Connectors | M8 (pico), 8 single-pin connectors |
| Connector pinout | Pin 1 24 V dc, pin 3 common, pins 4 inputs 0-7 on M8-A through M8-H |
| Keyswitch position | 1 |
| PointBus current | 75 mA at 5 V dc |
| Power dissipation | 1.6 W at 28.8 V dc (5.5 BTU/hr) |
| Data produced / consumed | 1 byte produced, 0 consumed (1 bit per channel) |
| Isolation | 50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s |
On-state 10-28.8 V dc, nominal 24 V dc; off-state input 5 V dc maximum; on-state current 2 mA nominal, 4 mA at 24 V dc minimum, 5 mA maximum; off-state leakage 1.5 mA maximum; impedance 3.6 kohm nominal, 4.7 kohm maximum. Of those numbers the two that decide a real installation are the on-state minimum of 10 V dc and the off-state maximum of 5 V dc. A two-wire sensor with enough leakage to hold the input above 5 V while it is off reads permanently on, and the published off-state leakage ceiling of 1.5 mA is the number to compare against the sensor datasheet before the panel is wired.
Input delay is 0.5 ms hardware plus 0-63 ms selectable in the module. That means the floor is a 0.5 ms hardware delay and the filter can add up to 63 ms, which is the difference between counting a short pulse and rejecting contact bounce on a mechanical limit switch. A machine that counts parts and one that watches a safety gate want different settings from the same module, and neither wants a different catalog number.
The input is non-isolated with a 50 V rms continuous withstand between field and backplane, and the module produces one byte and consumes none. One bit per channel, 0 for off and 1 for on, is the entire interface the controller sees; the connector arrangement on the face of the module changes nothing about that byte.
This string is the sinking member of the 8-channel pair: the field device pulls the input down to common, which is the arrangement a PNP sensor needs, and the supply stays on the module side. Cross it with the sourcing member on one machine and the wiring is still legal but the spare list doubles, so the direction is fixed once per machine rather than per block.
A sinking input takes the field device to common, which is the arrangement for a PNP sensor that switches the 24 V supply. The sourcing member of this family takes the device to the supply instead. Running both on one machine is perfectly legal, but it turns one spare into two, and the spare decision is made at the catalog number rather than in the storeroom.
Eight single-pin pico shells mean eight individual cord sets and eight sealing points on one block. A channel fault is found by unplugging one cable, and the same granularity is what makes an M8 installation slower to land than a multi-pin one. The block is published in three shells at the same eight channels, and the electrical behaviour does not change with the shell.
The 8-channel sinking block is published in three connector shells at the same channel count: M12 micro, M23 mini and M8 pico. M8 gives eight single-pin shells and therefore eight individual cord sets, M12 gives four shells with two inputs each, and M23 gives one twelve-pin shell. The electrical behaviour is the same; the cable preparation and the number of possible sealing faults are not.
| Parameter | Value |
| Dimensions with base | 120 H x 72 W x 42 D mm (4.72 x 2.83 x 1.65 in.) for I/O modules; 112 H x 72 W x 65 D mm (4.41 x 2.83 x 2.56 in.) for the DeviceNet adapters |
| Enclosure rating | Meets IP65/66/67 when marked; the sealed housing needs no cabinet, though a plant with washdown or corrosive atmosphere can still require one |
| Operating temperature | -20 to 60 degrees C (-4 to 140 degrees F), IEC 60068-2-1 cold, 60068-2-2 dry heat and 60068-2-14 thermal shock |
| Storage temperature | -40 to 85 degrees C (-40 to 185 degrees F) |
| Relative humidity | 5 to 95 percent non-condensing, IEC 60068-2-30 damp heat |
| Shock and vibration | Operating 30 g, non-operating 50 g; 5 g at 10-500 Hz operating |
| Isolation | 50 V rms continuous withstand, tested at 1,250 V ac rms for 60 s |
| ESD and RF immunity | 6 kV contact and 8 kV air discharge, 10 V/m radiated RF from 30 MHz to 2,000 MHz, 10 Vrms conducted RF from 150 kHz to 80 MHz |
| Transient immunity | Plus or minus 3 kV at 5 kHz EFT on signal ports, plus or minus 1 kV line-to-line and plus or minus 2 kV line-to-earth surge |
| Emissions | CISPR 11 Group 1 Class A |
| Mounting | Mounted on a grounded metal plate with #8 (M4) screws; base torque 7.5 in-lb in aluminium and 16 in-lb in steel; the ground lug is also a mounting hole |
| Weight | 0.29 kg (0.64 lb) with base |
| Field power bus | 24 V dc nominal, 10 to 28.8 V dc range |
| PointBus current | 75 mA at 5 V dc for digital and analog modules, 110 mA for 1738-SSIM23 |
Mounting is part of the electrical path: the module sits on a base, the base is fixed to a grounded metal plate with #8 (M4) screws, and the ground lug is also a mounting hole. The conductive path therefore runs through the base and the plate rather than through the module, which is why a module swapped onto a dirty base measures as a missing earth and reads like an electronics fault.
The family is built so the module is the replaceable unit and the base stays on the machine. The keyswitch position on the base has to match the module class, and a module inserted one position off is not a wiring error that can be traced with a meter but a mapping error that appears as shifted channels. That is the difference between a field-wired rack and a sealed I/O system: there is no terminal strip to inspect, only the position and the adapter map.
The same electrical function is published under other strings in this family: 1738-IB8M12, 1738-IB8M23, 1738-IV8M12. A substitution between them is a change of shell and cord-set preparation rather than a change of channel behaviour, and the keyswitch position is what has to stay compatible with the base already on the machine.
Connector shells are the part of the ordering decision a drawing rarely shows. M8 is a single-pin pico shell, M12 is a four or five pin micro shell, M23 is a twelve pin shell, and the same channel count can be delivered in three different shell sizes with three different cable preparations. A plant that standardises on M12 cord sets buys the M12 variant; a plant that already runs M8 patch cables buys the M8 variant and gets the same eight channels in eight single-pin shells, and the field wiring effort differs accordingly.
The environmental claims in this family are stated per module and per connector: IP65/66/67 applies when the connector caps are tightened, and the installation instructions repeat the attention note that all connectors and caps have to be securely tightened to keep the seal. That single step is where most field failures on sealed I/O originate, and it is a mechanical check rather than a network check.
Base torque is a published value rather than a habit: 7.5 in-lb in aluminium and 16 in-lb in steel for the #8 (M4) mounting screws, and the ground lug doubles as a mounting hole. A base fixed at the wrong torque in aluminium either loses its earth path or strips the thread.
Field power and PointBus power are two separate budgets. The bus current listed for each module is drawn at 5 V dc from the adapter, and the field power at 10 to 28.8 V dc is what the sensors and the loads take; a segment planned on one of them and commissioned on the other trips on the one that was not counted.
What this page does not claim matters as much as what it does. It states no cycle time, no maximum cable length and no network baud rate for this catalog number, because those belong to the segment and the adapter rather than to the module, and a figure of that kind copied into a page becomes a specification nobody can trace back to a publication. Where the source documents do fix a value - the channel count, the shell, the current limit, the isolation rating, the temperature window, the data size - it is on this page with the publication named.
No lifecycle statement and no price is implied. The electrical, environmental and data-map figures are quoted from the ArmorPoint installation instructions (1738-IN001 for dc outputs, 1738-IN002 for dc inputs, 1738-IN003 for analog inputs and the temperature input instructions) and the DeviceNet adapter user manual 1738-UM001.