logo
Home ProductsAB Panelview HMI 2711

Allen Bradley Panel 2711P-RW6 / 2711PRW6

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley Panel 2711P-RW6 / 2711PRW6

China Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier
Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier Allen Bradley Panel 2711P-RW6 / 2711PRW6 supplier

Large Image :  Allen Bradley Panel 2711P-RW6 / 2711PRW6

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley Panel 2711P-RW6 / 2711PRW6

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $376.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: T/T, Western Union and Paypal,
Supply Ability: 2 PCS
Detailed Product Description

2711P-RW6 technical data PDF download 2711P-RW6 CompactFlash card

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PanelView Plus memory and battery part

The 2711P-RW6 is CompactFlash card for the PanelView Plus range: 128 MB Internal CompactFlash Card with Open Windows CE Operating System and FactoryTalk View Machine Edition Software.

this is a memory, operating-system card or clock-battery part; it is the lowest-cost way to fix an under-specified or dead unit

2711P-RR64 64 MB SODIMM Memory IN STOCK
2711P-RR128 128 MB SODIMM Memory IN STOCK
2711P-RR256 256 MB SODIMM Memory IN STOCK
2711P-RY2032 Replacement Battery for PanelView Plus 700-1500 and PanelView Plus CE IN STOCK
2711P-RW2 Accessory, 128 MB Memory, CompactFlash IN STOCK
2711P-RW3 PanelView Plus Accessory, 256 MB CompactFlash with FactoryTalk View Machine Edition software for standard logic modules IN STOCK
2711P-RW6 128 MB Internal CompactFlash Card with Open Windows CE Operating System and FactoryTalk View Machine Edition Software IN STOCK
2711P-RW7 256 MB Internal CompactFlash Card with Open Windows CE Operating System and FactoryTalk View Machine Edition Software IN STOCK

Product Specifications 2711P-RW6 (PDF)
 Application
 128 MB Internal CompactFlash Card with Open Windows CE Operating System and FactoryTalk View Machine Edition Software
 Cat Num
 2711P-RW6
 Brand Name
 Rockwell
 Product Type
 CompactFlash card
 Capacity
 128 MB CompactFlash
 Software
 Open Windows CE operating system plus FactoryTalk View Machine Edition, for CE logic modules
 Lifecycle
 Discontinued January 04, 2019
 Replacement
 No planned Rockwell replacement
 Fits Family
 See application line

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 2711P-UM006 (module specifications) and 2711P-TD001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

2711P-RW6 PanelView Plus spare part, original listing photograph 1 2711P-RW6 PanelView Plus spare part, original listing photograph 2

What 2711P-RW6 is

Official Rockwell description: 128 MB Internal CompactFlash Card with Open Windows CE Operating System and FactoryTalk View Machine Edition Software.

Spare-part role: this is a memory, operating-system card or clock-battery part; it is the lowest-cost way to fix an under-specified or dead unit.

It is ordered by this catalog number alone; no terminal order is required, and the part is a service item, not a kit that includes a display or a logic module.

Fits and application data

Capacity: 128 MB CompactFlash.

Software: Open Windows CE operating system plus FactoryTalk View Machine Edition, for CE logic modules.

Lifecycle and replacement route

Rockwell Automation discontinued 2711P-RW6 on January 04, 2019; the replacement category published for it is: No planned Rockwell replacement.

A discontinued spare is bought for one of three reasons: the machine is still in production and must keep the same front, the line is being cloned, or the panel is waiting for a planned migration and needs to run until then.

Check the terminal-side catalog number before ordering a replacement: a display module must match the input style of the front it sits on, and a logic module must match the power input (AC or DC) of the panel it serves.

Memory and battery notes

The SODIMM modules upgrade the RAM of a logic module; the CompactFlash cards carry the operating system and the Machine Edition runtime for the CE logic modules.

A card ordered for a standard logic module does not boot a CE logic module: the CE cards ship with the open Windows CE operating system, the standard cards with the Machine Edition runtime only.

The 2711P-RY2032 is a CR2032 coin cell equivalent, the same cell that keeps the real-time clock alive for 4 years minimum at 25 deg C on the 700...1500 terminals.

Buying a discontinued spare

The part number, not the terminal model, is what identifies this item; a photograph of the old part and the terminal nameplate settle the match.

For a logic module, confirm the power input letter (A or D) and the operating-system digit (8 or 9) before ordering; for a display module, confirm the input style (touch, keypad, keypad/touch) and whether the terminal is standard, marine or high-bright.

Ask for the date code when the part is a service exchange: an aged electrolytic or a lamp with run hours already on it costs the same as a fresh unit but fails sooner.

Related parts in this family

The table lists every catalog number of this part family that this site carries, with the official one-line description; the row in red is the item on this page.

  • 2711P-RR64 — 64 MB SODIMM Memory
  • 2711P-RR128 — 128 MB SODIMM Memory
  • 2711P-RR256 — 256 MB SODIMM Memory
  • 2711P-RY2032 — Replacement Battery for PanelView Plus 700-1500 and PanelView Plus CE
  • 2711P-RW2 — Accessory, 128 MB Memory, CompactFlash
  • 2711P-RW3 — PanelView Plus Accessory, 256 MB CompactFlash with FactoryTalk View Machine Edition software for standard logic modules
  • 2711P-RW6 — 128 MB Internal CompactFlash Card with Open Windows CE Operating System and FactoryTalk View Machine Edition Software
  • 2711P-RW7 — 256 MB Internal CompactFlash Card with Open Windows CE Operating System and FactoryTalk View Machine Edition Software

Parts within one family are not interchangeable across rows: the description carries the size, the input style or the certification that separates them.

FAQ — 2711P-RW6

What is 2711P-RW6?

128 MB Internal CompactFlash Card with Open Windows CE Operating System and FactoryTalk View Machine Edition Software.

Which memory size does 2711P-RW6 give?

128 MB CompactFlash.

Is 2711P-RW6 still available?

Rockwell discontinued it on January 04, 2019; replacement category: No planned Rockwell replacement.

Does 2711P-RW6 fit a PanelView Plus 6 logic module?

Yes for the RR memory modules; the RW cards are tied to the CE logic modules and the RY2032 battery fits the 700...1500 terminals.

What happens when the battery in 2711P-RW6 goes flat?

The terminal loses its clock and date on power-down until the cell is replaced; the application itself is unaffected.


Data sources. Technical values on this page come from the Rockwell Automation product page for this catalog number, 2711P-UM006 and 2711P-TD001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)