Allen Bradley PLC 1794-ACN15 / 1794-ACN15

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1794-ACN15 / 1794-ACN15

China Allen Bradley PLC 1794-ACN15 / 1794-ACN15 supplier
Allen Bradley PLC 1794-ACN15 / 1794-ACN15 supplier Allen Bradley PLC 1794-ACN15 / 1794-ACN15 supplier Allen Bradley PLC 1794-ACN15 / 1794-ACN15 supplier Allen Bradley PLC 1794-ACN15 / 1794-ACN15 supplier Allen Bradley PLC 1794-ACN15 / 1794-ACN15 supplier Allen Bradley PLC 1794-ACN15 / 1794-ACN15 supplier Allen Bradley PLC 1794-ACN15 / 1794-ACN15 supplier

Large Image :  Allen Bradley PLC 1794-ACN15 / 1794-ACN15

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-ACN15 / 1794-ACN15

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $305.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-ACN15 technical data PDF download FLEX I/O 1794-ACN15 / 1794ACN15 ControlNet Adapter

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-ACN15 is the single-media ControlNet adapter for FLEX I/O: one BNC connector, a node-select dial, and 8 modules behind it on a 5 Mbps ControlNet link.

It is the drop-in replacement for the Series C adapter, with firmware revision shown numerically in RSNetWorx for ControlNet, which is what makes a field swap traceable.

1794-AENT EtherNet/IP adapter, single RJ45, 8 modules IN STOCK
1794-AENTR dual-port EtherNet/IP adapter, redundancy capable IN STOCK
1794-AENTRXT dual-port EtherNet/IP adapter, extended temperature IN STOCK
1794-ACN15 ControlNet adapter, 5 Mbps, 8 modules IN STOCK
1794-ACN15K ControlNet adapter, 5 Mbps, conformal coated IN STOCK
1794-ACNR ControlNet adapter with redundant media IN STOCK
1794-ACNR15XT ControlNet adapter, redundant media, extended temperature IN STOCK
1794-ACN ControlNet adapter module, 8 modules IN STOCK
1794-ADN DeviceNet adapter, 8 modules IN STOCK
1794-ADNK DeviceNet adapter, conformal coated IN STOCK
1794-APB Profibus DP adapter, 8 modules IN STOCK
1794-APBDPV1 Profibus DP-V1 adapter, 8 modules IN STOCK
1794-ASB Remote I/O adapter, 8 modules IN STOCK
1794-ASB2 Remote I/O adapter, extended functionality IN STOCK
1794-ASBLT Remote I/O adapter with built-in termination IN STOCK

Product Specifications 1794-ACN15 (PDF)
 Application
 FLEX I/O ControlNet adapter
 Cat Num
 1794-ACN15
 Brand Name
 Rockwell
 I/O module capacity
 8 modules
 Supply voltage, input
 19.2...31.2V DC, 400 mA
 Supply voltage, output
 5V DC, 640 mA
 Inrush current
 14 A for 2 ms
 Communication rate
 5 Mbps
 ControlNet cable
 Belden RG-6/U
 Dimensions
 87.4 x 94 x 92 mm
 Operating temperature
 -25...55 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-ACN15 original product photograph, wide view 1794-ACN15 original product photograph, wide view 1794-ACN15 original product photograph, wide view

ControlNet side

5 Mbps communication rate over a Belden RG-6/U cable, with BNC connector A.

A node selection dial sets the ControlNet address on the front of the adapter.

A programming terminal NAP port lets a laptop join the segment through the adapter.

Comm A and Comm B indicators are red/green, together with an I/O status indicator.

Backplane side

8 modules per adapter, with 5V DC 640 mA output to the Flexbus.

19.2...31.2V DC input at 400 mA, the adapter's own supply requirement.

14 A inrush for 2 ms, which sets the 24V supply sizing.

Power terminals accept 22...12 AWG single wire or 22...16 AWG double wire, 105 deg C rated.

Mechanical

87.4 x 94 x 92 mm and 220 g, the same footprint as the redundant versions.

-25...55 deg C operating, 55 deg C maximum surrounding air.

50 g nonoperating shock and 5 g vibration at 10...500 Hz, per IEC 60068-2-27 and -2-6.

0.8 N*m terminal torque, locking tab onto 35 mm DIN rail.

Application

Existing ControlNet segments where the media is already installed.

Series C replacement, which the publication states as drop-in.

Not redundant media; the 1794-ACNR15 adds the second BNC.

Not EtherNet/IP.

Where it fits

Single-cable ControlNet islands.

Legacy FLEX I/O panels being kept on ControlNet.

Not extended temperature; the 1794-ACNR15XT reaches -25...70 deg C.

Not for DeviceNet devices.

FAQ — 1794-ACN15

What is the ControlNet data rate?

5 Mbps over Belden RG-6/U cable.

How many modules can it carry?

8 FLEX I/O modules.

What is the input supply?

19.2...31.2V DC at 400 mA, with 14 A inrush for 2 ms.

What is the Flexbus output?

5V DC at 640 mA.

How is the node address set?

With the node selection dial on the adapter.

What is the operating temperature?

-25...55 deg C.


Data sources. Technical values on this page come from Rockwell publication 1794-IN128 (FLEX I/O ControlNet Adapters). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1794-ACN15: FLEX I/O ControlNet adapter, single media

All values on this page are taken from Rockwell Automation publications 1794-IN101 (Series B) and 1794-IN128F-EN-P (Series D) for the FLEX I/O ControlNet adapter modules. Where the two series differ, both figures are shown rather than merged.

The 1794-ACN15 is the single-channel ControlNet adapter for a FLEX I/O slice: one BNC port (connector A), one node address, and a backplane for up to eight terminal bases. It is the part that decides whether a slice can be dropped onto an existing ControlNet segment without changing the media plan.

Series matters more here than on most Rockwell parts, because the mechanical envelope changed. Series B measures 87 x 94 x 69 mm; Series D measures 87.4 x 94 x 92 mm, the extra depth coming from the connector housing. A cabinet door or a cable duct sized against a Series B drawing will not clear a Series D adapter, so the series letter on the nameplate is worth checking before a replacement is ordered.

The electrical numbers changed as well. Series B quotes 450 mA maximum input current (330 mA at 24 V), 23 A inrush for 2 ms and 4.6 W dissipation at 19.2 V; Series D quotes 400 mA input, 14 A inrush for 2 ms and 3.4 W. Both drive the same 640 mA at 5 V DC onto the backplane and both run ControlNet at 5 Mbps, so a mixed population of B and D adapters on one segment is electrically compatible but not mechanically interchangeable.

Isolation is deliberately modest: 50 V continuous basic insulation, type tested at 860 V AC for 60 s between power, ControlNet and system. That is a logic-level separation, not a barrier for 120 V field circuits, which is why the field voltage lives on the terminal bases rather than on the adapter.

Commissioning is two steps that catch most site problems: set the node address on the dials (01...99) before power-up, and confirm the Status LED goes solid green rather than flashing green. Flashing green means the adapter is on the network but no owner has established a connection, which is a controller-side scan list problem rather than a wiring problem.

For a Series D adapter, the 24 V feed must come from a SELV or PELV source approved to EN/IEC 60950-1, EN/IEC 61010-2-201 or EN/IEC 62368-1. That is a newer requirement than the Series B text and it is the item most often missed when a panel built to an older drawing is upgraded with a Series D unit.

Specifications printed by Rockwell

AttributeValue
I/O capacity8 FLEX I/O modules on the backplane
Input power19.2...31.2 V DC, 400 mA (Series D) / 450 mA maximum, 330 mA at 24 V (Series B)
Backplane output5 V DC, 640 mA maximum
Inrush14 A for 2 ms (Series D); 23 A for 2 ms (Series B)
Communication rate5 Mbps ControlNet
Isolation50 V continuous, basic insulation; type tested 860 V AC for 60 s power to system, power to ControlNet and ControlNet to system (Series D). No isolation between ControlNet channels.
Power dissipation3.4 W maximum at 19.2 V DC (Series D); 4.6 W maximum at 19.2 V DC (Series B)
Terminal torque0.8 N*m (7 lb-in) on terminals C, D, E, F
Wire sizeSingle wire 0.33...2.5 mm2 (22...12 AWG); double wire 0.33...1.3 mm2 (22...16 AWG, not intermixed); 75 °C rated, 1.2 mm insulation maximum
Dimensions87.4 x 94 x 92 mm (3.44 x 3.7 x 3.6 in.), Series D; 87 x 94 x 69 mm (3.4 x 3.7 x 2.7 in.), Series B
Weight220 g (7.76 oz)
Operating temperature-25...+55 °C for 1794-ACN15 and 1794-ACNR15; -25...+70 °C for 1794-ACNR15XT

Installation facts that decide field failures

  • Backplane. The adapter is the head of the slice: its Flexbus connector drives up to eight terminal bases, and the base hook on the right rear of the adapter has to engage the notch on the first base or the backplane connection is not mechanically locked.
  • Node address. Node addressing is set on the two-dial switch, valid range 01...99. The dials are read by RSNetWorx for ControlNet; a duplicate address shows up as the Comm A and Comm B LEDs flashing red/off alternately, not as a comms failure on one channel.
  • Field power. Field power lands on terminals C (-V common, upper connector) and D (+V DC, lower connector); E and F pass -V common and +V DC to the next module in the series. Series D limits the power wiring run to 10 m (32.8 ft); the earlier Series B publication stated 3 m (9.8 ft), so a panel wired to the older limit is still inside specification.
  • Grounding. Grounding is through the DIN rail: the rail must be zinc-plated chromate-passivated steel, secured about every 200 mm, with end anchors, because the adapter has no separate chassis terminal.
  • Indicators. The Status LED tells the maintenance story: off means no power, flashing green means on-line but not connected, solid green means connected, flashing red means an I/O module was removed or a wrong module was inserted or a flash update is in progress, solid red means adapter failure.
  • Supply source. Series D adds an electrical safety requirement that the earlier publication does not state: the 24 V source feeding the adapter and all connected I/O must be a SELV or PELV supply approved to EN/IEC 60950-1, EN/IEC 61010-2-201 or EN/IEC 62368-1, and the field wiring must follow the applicable installation code such as NEC article 501-4(b) in Class I locations.
  • Hazardous area. Zone 2 use requires an enclosure of at least IP54, pollution degree 2, transient excursions held to 140% of the peak rated voltage, and the ATEX marking II 3G Ex nA IIC T4 Gc (LCIE 01 ATEX 6020 X). The redundant adapters also carry DEMKO 14 ATEX 1342501X and IECEx UL 14.0066.

Mounting follows the same sequence as the terminal bases: hook the rear lip on a 35 x 7.5 x 1 mm top-hat rail (199-DR1 / EN 50022), rotate onto the rail, press down until the locking tab snaps, then push the Flexbus connector into the adapter. The first terminal base hooks into the notch on the right rear of the adapter, and that mechanical link is what keeps the backplane connection from opening under vibration.

Panel or wall mounting uses the 1794-NM1 mounting kit, covered by a separate installation instruction rather than by the adapter publication.

Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.