The 1794-ACN15 is the single-media ControlNet adapter for FLEX I/O: one BNC connector, a node-select dial, and 8 modules behind it on a 5 Mbps ControlNet link.
It is the drop-in replacement for the Series C adapter, with firmware revision shown numerically in RSNetWorx for ControlNet, which is what makes a field swap traceable.
| 1794-AENT | EtherNet/IP adapter, single RJ45, 8 modules | IN STOCK |
| 1794-AENTR | dual-port EtherNet/IP adapter, redundancy capable | IN STOCK |
| 1794-AENTRXT | dual-port EtherNet/IP adapter, extended temperature | IN STOCK |
| 1794-ACN15 | ControlNet adapter, 5 Mbps, 8 modules | IN STOCK |
| 1794-ACN15K | ControlNet adapter, 5 Mbps, conformal coated | IN STOCK |
| 1794-ACNR | ControlNet adapter with redundant media | IN STOCK |
| 1794-ACNR15XT | ControlNet adapter, redundant media, extended temperature | IN STOCK |
| 1794-ACN | ControlNet adapter module, 8 modules | IN STOCK |
| 1794-ADN | DeviceNet adapter, 8 modules | IN STOCK |
| 1794-ADNK | DeviceNet adapter, conformal coated | IN STOCK |
| 1794-APB | Profibus DP adapter, 8 modules | IN STOCK |
| 1794-APBDPV1 | Profibus DP-V1 adapter, 8 modules | IN STOCK |
| 1794-ASB | Remote I/O adapter, 8 modules | IN STOCK |
| 1794-ASB2 | Remote I/O adapter, extended functionality | IN STOCK |
| 1794-ASBLT | Remote I/O adapter with built-in termination | IN STOCK |
Application |
FLEX I/O ControlNet adapter |
Cat Num |
1794-ACN15 |
Brand Name |
Rockwell |
I/O module capacity |
8 modules |
Supply voltage, input |
19.2...31.2V DC, 400 mA |
Supply voltage, output |
5V DC, 640 mA |
Inrush current |
14 A for 2 ms |
Communication rate |
5 Mbps |
ControlNet cable |
Belden RG-6/U |
Dimensions |
87.4 x 94 x 92 mm |
Operating temperature |
-25...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
5 Mbps communication rate over a Belden RG-6/U cable, with BNC connector A.
A node selection dial sets the ControlNet address on the front of the adapter.
A programming terminal NAP port lets a laptop join the segment through the adapter.
Comm A and Comm B indicators are red/green, together with an I/O status indicator.
8 modules per adapter, with 5V DC 640 mA output to the Flexbus.
19.2...31.2V DC input at 400 mA, the adapter's own supply requirement.
14 A inrush for 2 ms, which sets the 24V supply sizing.
Power terminals accept 22...12 AWG single wire or 22...16 AWG double wire, 105 deg C rated.
87.4 x 94 x 92 mm and 220 g, the same footprint as the redundant versions.
-25...55 deg C operating, 55 deg C maximum surrounding air.
50 g nonoperating shock and 5 g vibration at 10...500 Hz, per IEC 60068-2-27 and -2-6.
0.8 N*m terminal torque, locking tab onto 35 mm DIN rail.
Existing ControlNet segments where the media is already installed.
Series C replacement, which the publication states as drop-in.
Not redundant media; the 1794-ACNR15 adds the second BNC.
Not EtherNet/IP.
Single-cable ControlNet islands.
Legacy FLEX I/O panels being kept on ControlNet.
Not extended temperature; the 1794-ACNR15XT reaches -25...70 deg C.
Not for DeviceNet devices.
What is the ControlNet data rate?
5 Mbps over Belden RG-6/U cable.
How many modules can it carry?
8 FLEX I/O modules.
What is the input supply?
19.2...31.2V DC at 400 mA, with 14 A inrush for 2 ms.
What is the Flexbus output?
5V DC at 640 mA.
How is the node address set?
With the node selection dial on the adapter.
What is the operating temperature?
-25...55 deg C.
All values on this page are taken from Rockwell Automation publications 1794-IN101 (Series B) and 1794-IN128F-EN-P (Series D) for the FLEX I/O ControlNet adapter modules. Where the two series differ, both figures are shown rather than merged.
The 1794-ACN15 is the single-channel ControlNet adapter for a FLEX I/O slice: one BNC port (connector A), one node address, and a backplane for up to eight terminal bases. It is the part that decides whether a slice can be dropped onto an existing ControlNet segment without changing the media plan.
Series matters more here than on most Rockwell parts, because the mechanical envelope changed. Series B measures 87 x 94 x 69 mm; Series D measures 87.4 x 94 x 92 mm, the extra depth coming from the connector housing. A cabinet door or a cable duct sized against a Series B drawing will not clear a Series D adapter, so the series letter on the nameplate is worth checking before a replacement is ordered.
The electrical numbers changed as well. Series B quotes 450 mA maximum input current (330 mA at 24 V), 23 A inrush for 2 ms and 4.6 W dissipation at 19.2 V; Series D quotes 400 mA input, 14 A inrush for 2 ms and 3.4 W. Both drive the same 640 mA at 5 V DC onto the backplane and both run ControlNet at 5 Mbps, so a mixed population of B and D adapters on one segment is electrically compatible but not mechanically interchangeable.
Isolation is deliberately modest: 50 V continuous basic insulation, type tested at 860 V AC for 60 s between power, ControlNet and system. That is a logic-level separation, not a barrier for 120 V field circuits, which is why the field voltage lives on the terminal bases rather than on the adapter.
Commissioning is two steps that catch most site problems: set the node address on the dials (01...99) before power-up, and confirm the Status LED goes solid green rather than flashing green. Flashing green means the adapter is on the network but no owner has established a connection, which is a controller-side scan list problem rather than a wiring problem.
For a Series D adapter, the 24 V feed must come from a SELV or PELV source approved to EN/IEC 60950-1, EN/IEC 61010-2-201 or EN/IEC 62368-1. That is a newer requirement than the Series B text and it is the item most often missed when a panel built to an older drawing is upgraded with a Series D unit.
| Attribute | Value |
| I/O capacity | 8 FLEX I/O modules on the backplane |
| Input power | 19.2...31.2 V DC, 400 mA (Series D) / 450 mA maximum, 330 mA at 24 V (Series B) |
| Backplane output | 5 V DC, 640 mA maximum |
| Inrush | 14 A for 2 ms (Series D); 23 A for 2 ms (Series B) |
| Communication rate | 5 Mbps ControlNet |
| Isolation | 50 V continuous, basic insulation; type tested 860 V AC for 60 s power to system, power to ControlNet and ControlNet to system (Series D). No isolation between ControlNet channels. |
| Power dissipation | 3.4 W maximum at 19.2 V DC (Series D); 4.6 W maximum at 19.2 V DC (Series B) |
| Terminal torque | 0.8 N*m (7 lb-in) on terminals C, D, E, F |
| Wire size | Single wire 0.33...2.5 mm2 (22...12 AWG); double wire 0.33...1.3 mm2 (22...16 AWG, not intermixed); 75 °C rated, 1.2 mm insulation maximum |
| Dimensions | 87.4 x 94 x 92 mm (3.44 x 3.7 x 3.6 in.), Series D; 87 x 94 x 69 mm (3.4 x 3.7 x 2.7 in.), Series B |
| Weight | 220 g (7.76 oz) |
| Operating temperature | -25...+55 °C for 1794-ACN15 and 1794-ACNR15; -25...+70 °C for 1794-ACNR15XT |
Mounting follows the same sequence as the terminal bases: hook the rear lip on a 35 x 7.5 x 1 mm top-hat rail (199-DR1 / EN 50022), rotate onto the rail, press down until the locking tab snaps, then push the Flexbus connector into the adapter. The first terminal base hooks into the notch on the right rear of the adapter, and that mechanical link is what keeps the backplane connection from opening under vibration.
Panel or wall mounting uses the 1794-NM1 mounting kit, covered by a separate installation instruction rather than by the adapter publication.
Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.