logo
Home ProductsAB FlexLogix I/O 1794

Allen Bradley PLC 1794-OV32 / 1794-OV32

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1794-OV32 / 1794-OV32

China Allen Bradley PLC 1794-OV32 / 1794-OV32 supplier
Allen Bradley PLC 1794-OV32 / 1794-OV32 supplier Allen Bradley PLC 1794-OV32 / 1794-OV32 supplier Allen Bradley PLC 1794-OV32 / 1794-OV32 supplier Allen Bradley PLC 1794-OV32 / 1794-OV32 supplier Allen Bradley PLC 1794-OV32 / 1794-OV32 supplier

Large Image :  Allen Bradley PLC 1794-OV32 / 1794-OV32

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-OV32 / 1794-OV32

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $235.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-OV32 technical data PDF download FLEX I/O 1794-OV32 32-Point Sinking Output Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-OV32 is the thirty-two point sinking output module, on a 1794-TB32 or 1794-TB32S base and a 4.5...5.5V DC field supply.

It is the sinking companion to the 1794-OB32P: same base, same density, opposite output polarity, and no channel protection beyond the external fuse.

1794-OB8 8-point 24V DC sourcing output module IN STOCK
1794-OB8EP 8-point 2 A electronically fused sourcing output module IN STOCK
1794-OB16 16-point 24V DC sourcing output module IN STOCK
1794-OB16P 16-point protected sourcing output module IN STOCK
1794-OB16D 16-point diagnostic 24V DC output module IN STOCK
1794-OB32P 32-point protected sourcing output module IN STOCK
1794-OB16PXT 16-point protected sourcing output, extended temperature IN STOCK
1794-OB8EPXT 8-point 2 A electronically fused output, extended temperature IN STOCK
1794-OV16 16-point sinking output module IN STOCK
1794-OV16P 16-point protected sinking output module IN STOCK
1794-OV32 32-point sinking output module IN STOCK
1794-OC16 16-point 48V DC sourcing output module IN STOCK
1794-OG16 16-point 5V DC sourcing output module IN STOCK
1794-OW8 8-point isolated relay output module IN STOCK

Product Specifications 1794-OV32 (PDF)
 Application
 FLEX I/O high-density sinking output
 Cat Num
 1794-OV32
 Brand Name
 Rockwell
 Outputs
 32, current, sinking
 External supply
 4.5...5.5V DC
 On-state voltage drop
 0.2V DC max
 Output current
 500 mA per channel, 8 A per module
 On-state current, min
 0.15 mA per channel
 External supply current
 100 mA at 5V DC
 Isolation
 50V continuous; tested 707V DC for 60 s
 Power dissipation
 4.4 W max at 31.2V DC (8.53 BTU/hr)
 Terminal base
 1794-TB32, 1794-TB32S
 Operating temperature
 0...55 °C (32...131 °F)

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-OV32 original product photograph, wide view 1794-OV32 original product photograph, wide view 1794-OV32 original product photograph, wide view

Output circuit

Thirty-two sinking outputs, 500 mA per channel and 8 A per module, with a 0.15 mA minimum on-state current per channel.

0.2V DC maximum drop keeps the load voltage at the supply rail, which matters on a 5V interface card with a narrow threshold window.

No internal fusing: Rockwell specifies an external SAN-O M04-800 mA fuse per output channel.

8 A for the module against thirty-two channels at 500 mA means the module limit binds long before every channel runs at rating.

The 100 mA supply draw is constant whether one channel or thirty-two are energised, which simplifies the 5V budget.

With no internal fusing, a shorted interface card is cleared by the external fuse and the module survives the event.

At 0...55 °C the card suits a normally ventilated enclosure rather than a cold-store panel.

The TB32 base is shared with the 32-point input and protected output cards, so the wiring diagram stays familiar across the slot.

Two groups of sixteen follow the TB32 row layout, with supply and common on the 34...51 row and no connections at terminals 16, 33, 34 and 51.

With no diagnostics, a dead group points at the group supply first, then the base terminals, then the card — in that order.

Supply

100 mA at 5V DC is the module's own draw from the external supply, distinct from the load current through the outputs.

<4.5...5.5V DC supply range — the same logic-level rail as the 16-point sinking modules.

4.4 W maximum dissipation (8.53 BTU/hr) at 31.2V DC, with a 0...55 °C operating range.

Isolation and base

707V DC for 60 s type tested at 50V continuous basic insulation, field side to system, no channel-to-channel isolation.

1794-TB32 or 1794-TB32S only. The 32-point base brings the terminals for both groups to one slot.

0...55 °C against -20...55 °C on the 16-point sinking card — the density costs cold-range headroom.

Wiring practice

Sinking outputs share a common, so the load returns are tied together on the base; the field supply positive goes to the load side.

Two groups of sixteen follow the TB32 row layout, with the group supply and common on the 34...51 row.

Keyswitch position must match before insertion, and wiring category 2 governs conductor routing.

Because the outputs are unfused, a single shorted load draws its channel current until the external fuse clears, and the TB32 terminals are the place that current has to pass.

When 32 sinking outputs pay

Dense logic-level interface panels. Thirty-two sinking drivers on one slot suit a bank of interface relays or opto cards.

Common-positive field wiring is preserved, which is why the sinking family exists at all.

Not for 24V loads. The 4.5...5.5V DC supply and the sinking stage belong to the 5V logic side of a panel.

FAQ — 1794-OV32

How many outputs has the 1794-OV32?

Thirty-two sinking outputs on one TB32 base.

What supply does it need?

4.5...5.5V DC, drawing 100 mA at 5V DC from the external supply.

What is the current rating?

500 mA per channel and 8 A per module, with a 0.2V DC maximum drop.

Which base is required?

1794-TB32 or 1794-TB32S.

Is it protected or fused?

Neither internally: external SAN-O M04-800 mA fuses are specified per output.

What is the operating temperature?

0...55 °C, with 4.4 W maximum dissipation at 31.2V DC.


Data sources. Technical values on this page come from Rockwell publication 1794-SG002 (digital DC output comparison, Table 13) and 1794-DU001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Choosing between the FLEX I/O digital output modules

Catalog numberOutputsPer-channel currentModule ceilingTerminal base
1794-OB88, current, sourcing500 mA per channel4 A per module1794-TB2, -TB3, -TB3S, -TB3K, -TB3SK
1794-OV1616, current, sinking500 mA per channel8 A per module1794-TB3, -TB3S, -TB3K, -TB3SK
1794-OV16P16, current, sinking, protected500 mA per channel8 A per module1794-TB3, -TB3S, -TB3K, -TB3SK
1794-OB1616, current, sourcing500 mA per channel8 A per module1794-TB2, -TB3, -TB3S, -TB3K, -TB3SK
1794-OB16D16, sourcing, with diagnostics500 mA per channel8 A per module1794-TB3, -TB3S, -TB3K, -TB3SK
1794-OV3232, current, sinking500 mA per channel8 A per module1794-TB32, 1794-TB32S
1794-OB32P32, sourcing, protected, two groups of 16500 mA per channelNot published1794-TB32, 1794-TB32S

The comparison below puts the whole published digital-output set side by side, so a substitution is argued from the same columns rather than from a remembered rule of thumb.

For 1794-OV32 the published row reads 32, current, sinking, at 500 mA per channel with a module ceiling of 8 A per module; the supply window is Not published, and it mounts on 1794-TB32, 1794-TB32S.

Heat is the second constraint: the dissipation figure is what the enclosure carries at full output voltage, and a sealed cabinet with several islands adds those figures rather than the current ratings.

Off-state leakage is not printed for this module in the source publication, so a two-wire device sharing the field supply has to be checked against its own datasheet before the panel is released.

Related numbers

Related models, options and spare parts for this range are listed in the Allen-Bradley Flex I/O 1794 modules category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)