The 1794-OV16P is the protected sinking sixteen-point output module: same sinking stage and 4.5...5.5V DC field supply as the 1794-OV16, with electronic protection on each channel.
It is used where a sinking convention is fixed by the existing panel wiring and the load is prone to shorting — the protection keeps the module in service instead of the fuse.
| 1794-OB8 | 8-point 24V DC sourcing output module | IN STOCK |
| 1794-OB8EP | 8-point 2 A electronically fused sourcing output module | IN STOCK |
| 1794-OB16 | 16-point 24V DC sourcing output module | IN STOCK |
| 1794-OB16P | 16-point protected sourcing output module | IN STOCK |
| 1794-OB16D | 16-point diagnostic 24V DC output module | IN STOCK |
| 1794-OB32P | 32-point protected sourcing output module | IN STOCK |
| 1794-OB16PXT | 16-point protected sourcing output, extended temperature | IN STOCK |
| 1794-OB8EPXT | 8-point 2 A electronically fused output, extended temperature | IN STOCK |
| 1794-OV16 | 16-point sinking output module | IN STOCK |
| 1794-OV16P | 16-point protected sinking output module | IN STOCK |
| 1794-OV32 | 32-point sinking output module | IN STOCK |
| 1794-OC16 | 16-point 48V DC sourcing output module | IN STOCK |
| 1794-OG16 | 16-point 5V DC sourcing output module | IN STOCK |
| 1794-OW8 | 8-point isolated relay output module | IN STOCK |
Application |
FLEX I/O protected sinking output |
Cat Num |
1794-OV16P |
Brand Name |
Rockwell |
Outputs |
16, current, sinking, protected |
External supply |
4.5...5.5V DC |
On-state voltage drop |
0.2V DC max |
Output current |
500 mA per channel, 8 A per module |
Off-state leakage |
0.5 mA max |
External supply current |
20...65 mA |
Isolation |
50V continuous; tested 1770V DC for 60 s |
Power dissipation |
4.2 W max at 31.2V DC (14.3 BTU/hr) |
Terminal base |
1794-TB3, -TB3S, -TB3K, -TB3SK |
Operating temperature |
-20...55 °C (-4...131 °F) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
500 mA per channel, 8 A per module with 0.2V DC maximum drop and 0.5 mA maximum off-state leakage.
<Electronic protection against short circuit and overload, with automatic recovery when the fault is removed and no fault bit to the processor.
<4.5...5.5V DC external supply at 20...65 mA — the protection does not change the supply requirement.
Protection protects the module, not the field wiring, so an external fuse remains the wiring standard in most panels.
Because the sinking stage shares a common, a short on one channel is contained by the electronic protection but still loads the common.
The 5V rail means a 24V field device cannot be driven directly, whatever the protection rating suggests.
Recovery is automatic and silent, so a recurring fault appears only as a channel that drops out and returns.
Mixing P and non-P versions on one island is possible but lengthens the spare list; a single variant per island is simpler.
Output delays are 0.25 ms and 0.5 ms, the same as the unprotected module; substituting one for the other does not change a scan-based timing calculation.
No surge rating is printed for the protected sinking pair in the selection guide; the value is marked Not published rather than assumed.
Off-state leakage drops to 0.5 mA from the 1.0 mA of the unprotected version.
1770V DC for 60 s type tested at 50V continuous basic insulation, field side to system.
4.2 W maximum dissipation (14.3 BTU/hr) and -20...55 °C operating, matching the unprotected module.
<94 x 94 x 69 mm installed with the terminal base, on a 46 x 94 x 53 mm module body.
TB3, TB3S, TB3K or TB3SK, keyswitch position 2, wiring category 2 on the signal ports.
Common return for sixteen channels means a single field wiring fault can affect a group; the protection limits the consequence, not the cause.
<Pair with the 1794-IV16 where the island also needs sourcing inputs — the two cards share the sinking/sourcing convention of the field wiring.
Where a fuse is the panel standard, the unprotected 1794-OV16 with an external SAN-O M04-800 mA fuse is the conventional choice.
Where downtime matters more than a fuse, the P version avoids replacing a card for a chafed cable.
For 24V loads this module is not applicable; the OV range runs on a 5V logic supply.
What is the difference between 1794-OV16 and 1794-OV16P?
The P version adds electronic short-circuit and overload protection with automatic recovery; the electrical ratings and delays are otherwise the same.
What supply does the 1794-OV16P need?
4.5...5.5V DC, drawing 20...65 mA.
What is the per-channel rating?
500 mA sinking, 8 A per module, with a 0.2V DC maximum on-state drop.
Does it report faults to the processor?
No; protection is local and self-resetting, with the channel LED as the only indication.
Which bases fit?
1794-TB3, 1794-TB3S, 1794-TB3K and 1794-TB3SK.
What is the isolation rating?
50V continuous, type tested at 1770V DC for 60 s between field side and system.
| Catalog number | Outputs | Per-channel current | Module ceiling | Terminal base |
|---|---|---|---|---|
| 1794-OB8 | 8, current, sourcing | 500 mA per channel | 4 A per module | 1794-TB2, -TB3, -TB3S, -TB3K, -TB3SK |
| 1794-OV16 | 16, current, sinking | 500 mA per channel | 8 A per module | 1794-TB3, -TB3S, -TB3K, -TB3SK |
| 1794-OV16P | 16, current, sinking, protected | 500 mA per channel | 8 A per module | 1794-TB3, -TB3S, -TB3K, -TB3SK |
| 1794-OB16 | 16, current, sourcing | 500 mA per channel | 8 A per module | 1794-TB2, -TB3, -TB3S, -TB3K, -TB3SK |
| 1794-OB16D | 16, sourcing, with diagnostics | 500 mA per channel | 8 A per module | 1794-TB3, -TB3S, -TB3K, -TB3SK |
| 1794-OV32 | 32, current, sinking | 500 mA per channel | 8 A per module | 1794-TB32, 1794-TB32S |
| 1794-OB32P | 32, sourcing, protected, two groups of 16 | 500 mA per channel | Not published | 1794-TB32, 1794-TB32S |
When two output modules in this family look interchangeable on a drawing, the difference is usually the per-channel ceiling and the heat, not the point count.
For 1794-OV16P the published row reads 16, current, sinking, protected, at 500 mA per channel with a module ceiling of 8 A per module; the supply window is Not published, and it mounts on 1794-TB3, -TB3S, -TB3K, -TB3SK.
A terminal base is not interchangeable across this table without checking the row assignment, because the same base can put the outputs on a different row for a sinking module than for a sourcing one.
Off-state leakage is the number that decides whether a two-wire sensor sharing the field supply reads an output as off: 0.5 mA max on this module.
The Allen-Bradley Flex I/O 1794 modules category lists the related catalog numbers, options and accessories for this range.