The 1794-OF8IH is the isolated HART output: eight channels, 16-bit resolution, 0.305 uA per count, and channel-to-channel isolation so eight smart valves can sit at eight different field references.
Isolation plus HART is the combination that matters in a plant where the loops are separately powered and separately grounded, and where each device needs configuration and diagnostics over the same pair.
| 1794-IE8 | 8-channel analog input module | IN STOCK |
| 1794-IE8XT | 8-channel analog input module, extended temperature | IN STOCK |
| 1794-IE8H | 8-channel HART analog input module | IN STOCK |
| 1794-IE12 | 12-channel analog input module | IN STOCK |
| 1794-IE12K | 12-channel analog input module, conformal coated | IN STOCK |
| 1794-IF4I | 4-channel isolated analog input module | IN STOCK |
| 1794-IF4IXT | 4-channel isolated analog input, extended temperature | IN STOCK |
| 1794-IF4ICFXT | 4-channel isolated analog input, conformal coated | IN STOCK |
| 1794-IF8IH | 8-channel HART isolated analog input module | IN STOCK |
| 1794-IR8 | 8-channel RTD input module | IN STOCK |
| 1794-IRT8 | 8-channel thermocouple/RTD input module | IN STOCK |
| 1794-IRT8XT | 8-channel thermocouple/RTD input, extended temperature | IN STOCK |
| 1794-IT8 | 8-channel thermocouple/mV input module | IN STOCK |
| 1794-IE8XOE4 | 8-input, 4-output analog combination module | IN STOCK |
| 1794-IE4XOE2 | 4-input, 2-output analog combination module | IN STOCK |
| 1794-IF2XOF2I | 2-input, 2-output isolated analog combination module | IN STOCK |
| 1794-OE4 | 4-channel analog output module | IN STOCK |
| 1794-OE12 | 12-channel analog output module | IN STOCK |
Application |
FLEX I/O isolated HART analog output, 1794 terminal base |
Cat Num |
1794-OF8IH |
Brand Name |
Rockwell |
Channels |
8, HART, channel-to-channel isolated |
Output ranges |
4...20 mA with HART digital signal |
Resolution |
16 bits; 0.305 uA per count |
Conversion |
10 ms for all channels |
Step response |
Under 70 ms |
Accuracy |
0.1% of full scale at 25 deg C, 0.35% over 0...55 deg C |
Drift |
0.008% per deg C |
Load |
0...750 Ohm |
Isolation |
120V basic insulation; 1000V AC for 60 s between user power, channel and channel |
External supply current |
450 mA at 24V DC |
Power dissipation |
5.0 W at 31.2V DC (16 BTU/hr) |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Eight HART outputs, each isolated from the others and from the system, at 120V basic insulation.
1000V AC for 60 s is the type test between user power, channel and channel, which is the rating a panel drawing needs.
16 bits at 0.305 uA per count is the finest published resolution on any FLEX I/O analog output.
0.1% of full scale at 25 deg C , widening to 0.35% across the 0...55 deg C operating range, with 0.008% per deg C drift.
The HART signal rides the same 4...20 mA pair, so the loop remains readable by a plain current receiver.
10 ms for all eight channels is the analog conversion.
Under 70 ms step response is the published figure — slower than the non-HART isolated cards, because the HART layer sits in the path.
0...750 Ohm load gives room for a sense resistor and a barrier in the same loop, unlike the 680 Ohm ceiling of the non-isolated HART card.
450 mA at 24V DC is a real supply load: eight isolated HART channels are the heaviest analog output card in the line.
5.0 W at 31.2V DC (16 BTU/hr) is the heat to carry in the enclosure calculation.
0...55 deg C operating range — note the zero, not -20: this card is for a heated cabinet, and the drawing has to say so.
75 mm deep body matches the HART module family and needs the deeper base clearance.
Isolation means a barrier is usually unnecessary, but a 250V field circuit still needs one; 120V basic insulation is not a 250V rating.
One loop per channel with its own return is what the isolation buys; the eight returns must not be commoned at the terminals.
HART needs loop resistance to modulate, so the receiver impedance plus any series resistor must reach the modem's minimum.
Shield at the panel, and the HART handset or asset manager clips across the loop rather than in series with it.
Restore the configuration after a card exchange; the module holds channel configuration, not the field device's.
Separately grounded smart valve loops — the case for channel-to-channel isolation with HART.
Asset-management projects that need 16-bit resolution and per-loop diagnostics.
Not for unheated panels — the 0 deg C operating floor is the deciding constraint.
Not for fast loops — the 1794-OF4I settles in under 25 us without HART.
How many outputs has the 1794-OF8IH?
Eight HART analog outputs, isolated channel to channel.
What resolution does it offer?
16 bits at 0.305 uA per count.
What isolation does it provide?
120V basic insulation, type tested at 1000V AC for 60 s between user power, channel and channel.
What accuracy does it achieve?
0.1% of full scale at 25 deg C and 0.35% over 0...55 deg C.
What load can it drive?
0...750 Ohm on each loop.
What is the operating temperature?
0...55 deg C, with a 75 mm deep body.
| Catalog number | Channels | Ranges | Resolution | Accuracy |
|---|---|---|---|---|
| 1794-IE4XOE2 | 4 inputs and 2 outputs, individually configurable | 0...20 mA, +/-10V DC | Not published | 0.20% input, 0.425% current output, 0.133% voltage output, at 25 deg C |
| 1794-IE4XOE2XT | 4 inputs and 2 outputs, individually configurable | 0...20 mA, +/-10V DC | Not published | 0.20% input, 0.425% current output, 0.133% voltage output, at 25 deg C |
| 1794-OE8H | 8, HART, individually configurable, wire-off detection per channel | 4...20 mA with HART digital signal | 13 bits | 0.1% of full scale at 20 deg C |
| 1794-OF8IH | 8, HART, channel-to-channel isolated | 4...20 mA with HART digital signal | 16 bits; 0.305 uA per count | 0.1% of full scale at 25 deg C, 0.35% over 0...55 deg C |
| 1794-IF2XOF2I | 2 inputs and 2 outputs, channel-to-channel isolated | 0...20 mA, +/-10V DC | Not published | Not published |
| 1794-IF2XOF2IXT | 2 inputs and 2 outputs, channel-to-channel isolated | 0...20 mA, +/-10V DC | Not published | Not published |
The high-resolution rows of the FLEX I/O analog table differ mainly in three columns: how many channels sit on one module, which ranges the channel accepts, and what the published accuracy is at the top of the range.
For 1794-OF8IH the published row reads 8, HART, channel-to-channel isolated channels over 4...20 mA with HART digital signal, at 16 bits; 0.305 uA per count resolution and 0.1% of full scale at 25 deg C, 0.35% over 0...55 deg C accuracy; the external supply draws 450 mA at 24V DC and the module dissipates 5.0 W at 31.2V DC (16 BTU/hr).
A module that carries both input and output channels on the same base is the reason this table mixes the two: the range column has to be read twice, once for the input pair and once for the output pair.
Isolation on this module is published as 120V basic insulation; 1000V AC for 60 s between user power, channel and channel, which is what decides whether the field wiring can share a common with the backplane.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley Flex I/O 1794 modules category.