logo
Home ProductsAB FlexLogix I/O 1794

Allen Bradley PLC 1794-OE8H / 1794-OE8H

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1794-OE8H / 1794-OE8H

China Allen Bradley PLC 1794-OE8H / 1794-OE8H supplier
Allen Bradley PLC 1794-OE8H / 1794-OE8H supplier Allen Bradley PLC 1794-OE8H / 1794-OE8H supplier Allen Bradley PLC 1794-OE8H / 1794-OE8H supplier Allen Bradley PLC 1794-OE8H / 1794-OE8H supplier Allen Bradley PLC 1794-OE8H / 1794-OE8H supplier Allen Bradley PLC 1794-OE8H / 1794-OE8H supplier

Large Image :  Allen Bradley PLC 1794-OE8H / 1794-OE8H

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-OE8H / 1794-OE8H

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $980.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-OE8H technical data PDF download FLEX I/O 1794-OE8H / 1794OE8H 8-Channel HART Analog Output

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-OE8H is the eight-channel HART analog output: 4...20 mA with the digital HART signal superimposed, 13-bit resolution, and per-channel wire-off detection.

It is what a HART positioner or a smart valve expects. The 4...20 mA loop carries the process value; the HART channel carries configuration, diagnostics and secondary variables over the same two wires.

1794-IE8 8-channel analog input module IN STOCK
1794-IE8XT 8-channel analog input module, extended temperature IN STOCK
1794-IE8H 8-channel HART analog input module IN STOCK
1794-IE12 12-channel analog input module IN STOCK
1794-IE12K 12-channel analog input module, conformal coated IN STOCK
1794-IF4I 4-channel isolated analog input module IN STOCK
1794-IF4IXT 4-channel isolated analog input, extended temperature IN STOCK
1794-IF4ICFXT 4-channel isolated analog input, conformal coated IN STOCK
1794-IF8IH 8-channel HART isolated analog input module IN STOCK
1794-IR8 8-channel RTD input module IN STOCK
1794-IRT8 8-channel thermocouple/RTD input module IN STOCK
1794-IRT8XT 8-channel thermocouple/RTD input, extended temperature IN STOCK
1794-IT8 8-channel thermocouple/mV input module IN STOCK
1794-IE8XOE4 8-input, 4-output analog combination module IN STOCK
1794-IE4XOE2 4-input, 2-output analog combination module IN STOCK
1794-IF2XOF2I 2-input, 2-output isolated analog combination module IN STOCK
1794-OE4 4-channel analog output module IN STOCK
1794-OE12 12-channel analog output module IN STOCK

Product Specifications 1794-OE8H (PDF)
 Application
 FLEX I/O HART analog output, 1794 terminal base
 Cat Num
 1794-OE8H
 Brand Name
 Rockwell
 Channels
 8, HART, individually configurable, wire-off detection per channel
 Output ranges
 4...20 mA with HART digital signal
 Resolution
 13 bits
 Conversion
 10 ms for all channels
 Step response
 13 ms to 99% of full scale, 115 ms while HART is communicating
 Accuracy
 0.1% of full scale at 20 deg C
 Drift
 0.010% of full scale per deg C
 Load
 0...680 Ohm at 22 mA, 0...770 Ohm at 20 mA
 Isolation
 50V continuous, field to system
 External supply current
 255 mA at 24V DC
 Power dissipation
 6.1 W at 31.2V DC (20.8 BTU/hr)
 Operating temperature
 -20...55 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-OE8H original product photograph, wide view 1794-OE8H original product photograph, wide view 1794-OE8H original product photograph, wide view

HART output

Eight current outputs with HART, each configured independently and each with its own wire-off detection bit.

13 bits of resolution on a 4...20 mA span, which is the level smart instruments were designed around.

0.1% of full scale at 20 deg C with 0.010% per deg C drift is the published analog performance.

The HART signal is superimposed on the loop current, so a conventional 4...20 mA receiver still reads the process value without a HART master.

An adapter is required: the card is listed with ControlNet, EtherNet/IP and PROFIBUS DP FLEX I/O adapters, and the HART data has to reach a host that speaks it.

Speed and load

10 ms conversion for all eight channels is the analog update; the HART dialogue runs on top of it, not instead of it.

13 ms to 99% of full scale, 115 ms while HART is communicating is the honest pair of figures: a HART transaction stretches the step response by roughly nine times.

0...680 Ohm at 22 mA and 0...770 Ohm at 20 mA is the load window; a 250 Ohm sense resistor in the loop stays inside it, a 750 Ohm barrier may not.

255 mA at 24V DC and 6.1 W (20.8 BTU/hr) at 31.2V DC is the supply and heat budget for eight channels.

Isolation and environment

50V continuous field to system is the isolation rating, so the card assumes a single field reference rather than eight floating circuits.

-20...55 deg C operating range, 75 mm deep body — the HART cards are deeper than the standard analog modules and the enclosure depth has to allow it.

Wire category 2 on signal ports is stated in the publication and belongs on the panel drawing.

Per-channel wire-off detection reports an open loop as a diagnostic rather than as a 0% reading that looks like a valid measurement.

Wiring and commissioning

HART needs a minimum loop resistance to modulate, so a low-impedance receiver may need a series resistor; the 680 or 770 Ohm ceiling is the other limit.

One loop per channel, with the shield at the panel, and the HART master connected across the loop rather than in series.

Configuration is held in the module, so a card exchange on a running line needs the configuration restored before the loops report correctly.

Field power comes from the external supply, not from the module; 255 mA is the module's own consumption.

Where it fits

Smart valve and positioner fleets that already use a HART handheld or asset management system.

Retrofit loops where the 4...20 mA signal has to keep working for the existing control system while HART is added.

Not for isolated channels — the 1794-OF8IH publishes channel-to-channel isolation with HART.

Not for faster loops; 115 ms step response during HART traffic rules out a fast-acting valve.

FAQ — 1794-OE8H

How many outputs has the 1794-OE8H?

Eight HART analog outputs with per-channel wire-off detection.

What resolution does it offer?

13 bits on a 4...20 mA span.

How fast is the output?

10 ms conversion for all channels; 13 ms to 99%, or 115 ms while HART is communicating.

What loop resistance is allowed?

0...680 Ohm at 22 mA and 0...770 Ohm at 20 mA.

What accuracy does it achieve?

0.1% of full scale at 20 deg C with 0.010% per deg C drift.

What isolation does it provide?

50V continuous field to system; no channel-to-channel isolation.


Data sources. Technical values on this page come from Rockwell publication 1794-SG002 (FLEX I/O Selection Guide, Table 33) and 1794-IN093. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Choosing among the high-resolution FLEX I/O analog modules

Catalog numberChannelsRangesResolutionAccuracy
1794-IE4XOE24 inputs and 2 outputs, individually configurable0...20 mA, +/-10V DCNot published0.20% input, 0.425% current output, 0.133% voltage output, at 25 deg C
1794-IE4XOE2XT4 inputs and 2 outputs, individually configurable0...20 mA, +/-10V DCNot published0.20% input, 0.425% current output, 0.133% voltage output, at 25 deg C
1794-OE8H8, HART, individually configurable, wire-off detection per channel4...20 mA with HART digital signal13 bits0.1% of full scale at 20 deg C
1794-OF8IH8, HART, channel-to-channel isolated4...20 mA with HART digital signal16 bits; 0.305 uA per count0.1% of full scale at 25 deg C, 0.35% over 0...55 deg C
1794-IF2XOF2I2 inputs and 2 outputs, channel-to-channel isolated0...20 mA, +/-10V DCNot publishedNot published
1794-IF2XOF2IXT2 inputs and 2 outputs, channel-to-channel isolated0...20 mA, +/-10V DCNot publishedNot published

Six analog modules share this table, and the shortest way to choose between them is to read the channels, the ranges and the accuracy in one pass rather than comparing datasheets page by page.

For 1794-OE8H the published row reads 8, HART, individually configurable, wire-off detection per channel channels over 4...20 mA with HART digital signal, at 13 bits resolution and 0.1% of full scale at 20 deg C accuracy; the external supply draws 255 mA at 24V DC and the module dissipates 6.1 W at 31.2V DC (20.8 BTU/hr).

Two channels at a published accuracy are worth more than four at an unstated one, and the source publication states the accuracy for each catalog number separately.

Isolation on this module is published as 50V continuous, field to system, which is what decides whether the field wiring can share a common with the backplane.

Related numbers

Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)