Product Details:
Payment & Shipping Terms:
|
The 1794-OE8H is the eight-channel HART analog output: 4...20 mA with the digital HART signal superimposed, 13-bit resolution, and per-channel wire-off detection.
It is what a HART positioner or a smart valve expects. The 4...20 mA loop carries the process value; the HART channel carries configuration, diagnostics and secondary variables over the same two wires.
| 1794-IE8 | 8-channel analog input module | IN STOCK |
| 1794-IE8XT | 8-channel analog input module, extended temperature | IN STOCK |
| 1794-IE8H | 8-channel HART analog input module | IN STOCK |
| 1794-IE12 | 12-channel analog input module | IN STOCK |
| 1794-IE12K | 12-channel analog input module, conformal coated | IN STOCK |
| 1794-IF4I | 4-channel isolated analog input module | IN STOCK |
| 1794-IF4IXT | 4-channel isolated analog input, extended temperature | IN STOCK |
| 1794-IF4ICFXT | 4-channel isolated analog input, conformal coated | IN STOCK |
| 1794-IF8IH | 8-channel HART isolated analog input module | IN STOCK |
| 1794-IR8 | 8-channel RTD input module | IN STOCK |
| 1794-IRT8 | 8-channel thermocouple/RTD input module | IN STOCK |
| 1794-IRT8XT | 8-channel thermocouple/RTD input, extended temperature | IN STOCK |
| 1794-IT8 | 8-channel thermocouple/mV input module | IN STOCK |
| 1794-IE8XOE4 | 8-input, 4-output analog combination module | IN STOCK |
| 1794-IE4XOE2 | 4-input, 2-output analog combination module | IN STOCK |
| 1794-IF2XOF2I | 2-input, 2-output isolated analog combination module | IN STOCK |
| 1794-OE4 | 4-channel analog output module | IN STOCK |
| 1794-OE12 | 12-channel analog output module | IN STOCK |
Application |
FLEX I/O HART analog output, 1794 terminal base |
Cat Num |
1794-OE8H |
Brand Name |
Rockwell |
Channels |
8, HART, individually configurable, wire-off detection per channel |
Output ranges |
4...20 mA with HART digital signal |
Resolution |
13 bits |
Conversion |
10 ms for all channels |
Step response |
13 ms to 99% of full scale, 115 ms while HART is communicating |
Accuracy |
0.1% of full scale at 20 deg C |
Drift |
0.010% of full scale per deg C |
Load |
0...680 Ohm at 22 mA, 0...770 Ohm at 20 mA |
Isolation |
50V continuous, field to system |
External supply current |
255 mA at 24V DC |
Power dissipation |
6.1 W at 31.2V DC (20.8 BTU/hr) |
Operating temperature |
-20...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Eight current outputs with HART, each configured independently and each with its own wire-off detection bit.
13 bits of resolution on a 4...20 mA span, which is the level smart instruments were designed around.
0.1% of full scale at 20 deg C with 0.010% per deg C drift is the published analog performance.
The HART signal is superimposed on the loop current, so a conventional 4...20 mA receiver still reads the process value without a HART master.
An adapter is required: the card is listed with ControlNet, EtherNet/IP and PROFIBUS DP FLEX I/O adapters, and the HART data has to reach a host that speaks it.
10 ms conversion for all eight channels is the analog update; the HART dialogue runs on top of it, not instead of it.
13 ms to 99% of full scale, 115 ms while HART is communicating is the honest pair of figures: a HART transaction stretches the step response by roughly nine times.
0...680 Ohm at 22 mA and 0...770 Ohm at 20 mA is the load window; a 250 Ohm sense resistor in the loop stays inside it, a 750 Ohm barrier may not.
255 mA at 24V DC and 6.1 W (20.8 BTU/hr) at 31.2V DC is the supply and heat budget for eight channels.
50V continuous field to system is the isolation rating, so the card assumes a single field reference rather than eight floating circuits.
-20...55 deg C operating range, 75 mm deep body — the HART cards are deeper than the standard analog modules and the enclosure depth has to allow it.
Wire category 2 on signal ports is stated in the publication and belongs on the panel drawing.
Per-channel wire-off detection reports an open loop as a diagnostic rather than as a 0% reading that looks like a valid measurement.
HART needs a minimum loop resistance to modulate, so a low-impedance receiver may need a series resistor; the 680 or 770 Ohm ceiling is the other limit.
One loop per channel, with the shield at the panel, and the HART master connected across the loop rather than in series.
Configuration is held in the module, so a card exchange on a running line needs the configuration restored before the loops report correctly.
Field power comes from the external supply, not from the module; 255 mA is the module's own consumption.
Smart valve and positioner fleets that already use a HART handheld or asset management system.
Retrofit loops where the 4...20 mA signal has to keep working for the existing control system while HART is added.
Not for isolated channels — the 1794-OF8IH publishes channel-to-channel isolation with HART.
Not for faster loops; 115 ms step response during HART traffic rules out a fast-acting valve.
How many outputs has the 1794-OE8H?
Eight HART analog outputs with per-channel wire-off detection.
What resolution does it offer?
13 bits on a 4...20 mA span.
How fast is the output?
10 ms conversion for all channels; 13 ms to 99%, or 115 ms while HART is communicating.
What loop resistance is allowed?
0...680 Ohm at 22 mA and 0...770 Ohm at 20 mA.
What accuracy does it achieve?
0.1% of full scale at 20 deg C with 0.010% per deg C drift.
What isolation does it provide?
50V continuous field to system; no channel-to-channel isolation.
| Catalog number | Channels | Ranges | Resolution | Accuracy |
|---|---|---|---|---|
| 1794-IE4XOE2 | 4 inputs and 2 outputs, individually configurable | 0...20 mA, +/-10V DC | Not published | 0.20% input, 0.425% current output, 0.133% voltage output, at 25 deg C |
| 1794-IE4XOE2XT | 4 inputs and 2 outputs, individually configurable | 0...20 mA, +/-10V DC | Not published | 0.20% input, 0.425% current output, 0.133% voltage output, at 25 deg C |
| 1794-OE8H | 8, HART, individually configurable, wire-off detection per channel | 4...20 mA with HART digital signal | 13 bits | 0.1% of full scale at 20 deg C |
| 1794-OF8IH | 8, HART, channel-to-channel isolated | 4...20 mA with HART digital signal | 16 bits; 0.305 uA per count | 0.1% of full scale at 25 deg C, 0.35% over 0...55 deg C |
| 1794-IF2XOF2I | 2 inputs and 2 outputs, channel-to-channel isolated | 0...20 mA, +/-10V DC | Not published | Not published |
| 1794-IF2XOF2IXT | 2 inputs and 2 outputs, channel-to-channel isolated | 0...20 mA, +/-10V DC | Not published | Not published |
Six analog modules share this table, and the shortest way to choose between them is to read the channels, the ranges and the accuracy in one pass rather than comparing datasheets page by page.
For 1794-OE8H the published row reads 8, HART, individually configurable, wire-off detection per channel channels over 4...20 mA with HART digital signal, at 13 bits resolution and 0.1% of full scale at 20 deg C accuracy; the external supply draws 255 mA at 24V DC and the module dissipates 6.1 W at 31.2V DC (20.8 BTU/hr).
Two channels at a published accuracy are worth more than four at an unstated one, and the source publication states the accuracy for each catalog number separately.
Isolation on this module is published as 50V continuous, field to system, which is what decides whether the field wiring can share a common with the backplane.
Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.