Product Details:
Payment & Shipping Terms:
|
1746-NI16V is the 16 Point Analog Voltage Input Module in the Allen-Bradley SLC 500 range: 1746 SLC System, 16 ch-Analog Voltage Input Module For Programmable Controller.
It occupies one I/O slot, takes both backplane rails, and is configured channel by channel from the processor; the ranges, resolution and filter settings below are the ones a project engineer needs before the loop is designed.
| 1746-NI4 | 4 Point Analog Input Module | IN STOCK |
| 1746-NI8 | 8 Point Analog Input Module | IN STOCK |
| 1746-NI16I | 16 Point Analog Input Module | IN STOCK |
| 1746-NI16V | 16 Point Analog Voltage Input Module | IN STOCK |
Application |
1746 SLC System, 16 ch-Analog Voltage Input Module For Programmable Controller |
Cat Num |
1746-NI16V |
Brand Name |
Rockwell |
Product Type |
16 Point Analog Voltage Input Module |
Channels |
16 single-ended voltage inputs |
Input range |
±10V dc, 0...10V dc, 0...5V dc, 1...5V dc |
Resolution |
16-bit, input resolution 312 µV |
Backplane current, 5V DC |
125 mA |
Backplane current, 24V DC |
75 mA |
Update time / filtering |
Sigma-Delta, filter 6/10/20/40/60/80/100/250 Hz |
Isolation |
500V ac for 1 s |
Lifecycle |
Discontinued |
Discontinued date |
Not published (Rockwell product page retired) |
Replacement category |
Engineering Replacement |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN001 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Official Rockwell description: 1746 SLC System, 16 ch-Analog Voltage Input Module For Programmable Controller.
16 Point Analog Voltage Input Module with 16 single-ended voltage inputs.
Application: 1746 SLC System, 16 ch-Analog Voltage Input Module For Programmable Controller.
Cat Num: 1746-NI16V.
Brand Name: Rockwell.
Product Type: 16 Point Analog Voltage Input Module.
Channels: 16 single-ended voltage inputs.
Input range: ±10V dc, 0...10V dc, 0...5V dc, 1...5V dc.
Resolution: 16-bit, input resolution 312 µV.
Backplane current, 5V DC: 125 mA.
Backplane current, 24V DC: 75 mA.
Update time / filtering: Sigma-Delta, filter 6/10/20/40/60/80/100/250 Hz.
Isolation: 500V ac for 1 s.
Lifecycle: Discontinued.
Discontinued date: Not published (Rockwell product page retired).
Replacement category: Engineering Replacement.
Every input channel is configured in the user program, not with jumpers: the NI4 uses four DIP switches for current or voltage selection, while the NI8 and NI16 are software configured and can be re-ranged without interrupting the processor.
A current input is a 249 Ω burden on the loop for the NI16I, so the transmitter needs enough compliance to drive the loop impedance plus the card; a voltage input is 20 MΩ on the NI16V and 760 kΩ on the NI4.
The module does not supply loop power. An unpowered 4...20 mA transmitter reads as a negative out-of-range value, which is the diagnostic that tells an open loop from a failed sensor.
Rockwell lists 1746-NI16V as Discontinued, discontinued date Not published (Rockwell product page retired), replacement category Engineering Replacement.
No replacement catalog number is printed on the Rockwell page, so the route is an engineering substitution with a re-ranged analogue front end, not a part-for-part swap.
Rockwell's migration guidance for Bulletin 1746 routes analog points to Compact 5000 analog modules with a Logix controller; machines that stay on SLC 500 are supported from the secondary market.
The terminal block, the slot address and the module ID code stay the same when a card is replaced by the same catalog number, which is why the original number still has a place in a maintenance spares list after the end of sale.
A modular SLC 500 reserves slot 0 for the processor or the adapter, so this module goes in any other I/O slot; the current drawn from 5V dc and 24V dc both count against the chassis supply.
The analog front end is factory calibrated and, on the newer cards, autocalibrates at power-up and on channel enable, so an accuracy figure quoted at 25 °C is what the card delivers without a field trim.
Isolation is 500V ac for 1 s between the field terminals and the backplane; that figure, not the channel count, is what decides whether a card can sit next to a drive with a noisy earth.
The card in red in the catalogue table at the top of this page is the one described here.
What is 1746-NI16V?
1746 SLC System, 16 ch-Analog Voltage Input Module For Programmable Controller. 16 Point Analog Voltage Input Module.
How many channels does 1746-NI16V have?
16 single-ended voltage inputs.
What ranges does 1746-NI16V accept?
Inputs: ±10V dc, 0...10V dc, 0...5V dc, 1...5V dc.
How much backplane current does 1746-NI16V draw?
125 mA at 5V dc and 75 mA at 24V dc.
Is 1746-NI16V still available?
Rockwell lists it as Discontinued, discontinued date Not published (Rockwell product page retired), replacement category Engineering Replacement.