1746-IB8 is the 8 Point DC Input Module in the Allen-Bradley SLC 500 range: 1746 SLC System, 8 ch-DC Input Module For Programmable Controller (sinking).
It sits in an SLC 500 chassis slot and exchanges data with the processor through the backplane image table; the points, voltage category and backplane current below are what decide whether it fits the slot and the power budget.
| 1746-IB8 | 8 Point DC Input Module | IN STOCK |
| 1746-IB16 | 16 Point DC Input Module | IN STOCK |
| 1746-IB32 | 32 Point DC Input Module | IN STOCK |
| 1746-IC16 | 16 Point 48V DC Input Module | IN STOCK |
| 1746-IH16 | 16 Point 125V DC Input Module | IN STOCK |
| 1746-ITB16 | 16 Point Fast Response DC Input Module | IN STOCK |
| 1746-ITV16 | 16 Point Fast Response DC Sourcing Input Module | IN STOCK |
| 1746-IV8 | 8 Point Digital Input Module | IN STOCK |
| 1746-IV16 | 16 Point Digital Input Module | IN STOCK |
| 1746-IV32 | 32 Point Digital Input Module | IN STOCK |
Application |
1746 SLC System, 8 ch-DC Input Module For Programmable Controller (sinking) |
Cat Num |
1746-IB8 |
Brand Name |
Rockwell |
Product Type |
8 Point DC Input Module |
Points |
8 inputs |
Points per common |
8 |
Voltage category |
24V DC signal input (sinking) |
Operating voltage |
10...30V DC (sinking) |
Backplane current, 5V DC |
0.050 A |
Backplane current, 24V DC |
0.0 A |
Signal delay, max |
On = 8 ms, Off = 8 ms |
Isolation |
1500V, electro-optical to control logic |
Lifecycle |
Discontinued |
Discontinued date |
August 31, 2018 |
Replacement category |
Engineering Replacement |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-IN027 (module specifications) and 1747-UM011 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Official Rockwell description: 1746 SLC System, 8 ch-DC Input Module For Programmable Controller (sinking).
8 Point DC Input Module, with 8 inputs and 8 per common terminal.
Application: 1746 SLC System, 8 ch-DC Input Module For Programmable Controller (sinking).
Cat Num: 1746-IB8.
Brand Name: Rockwell.
Product Type: 8 Point DC Input Module.
Points: 8 inputs.
Points per common: 8.
Voltage category: 24V DC signal input (sinking).
Operating voltage: 10...30V DC (sinking).
Backplane current, 5V DC: 0.050 A.
Backplane current, 24V DC: 0.0 A.
Signal delay, max: On = 8 ms, Off = 8 ms.
Isolation: 1500V, electro-optical to control logic.
Lifecycle: Discontinued.
Discontinued date: August 31, 2018.
Replacement category: Engineering Replacement.
A sinking input expects the field device to pull the terminal to DC common, a sourcing input expects the device to feed +24V DC into the terminal. Mixing the two conventions is the usual reason an input reads ON with nothing connected.
Off-state current is the leakage the input tolerates without turning on, so a two-wire sensor above that figure needs a loading resistor across the input.
Fast-response cards shorten the ON delay from 8 ms to 0.3 ms for a registration mark or a short pulse that a standard card would miss.
Rockwell lists 1746-IB8 as Discontinued, with the discontinued date August 31, 2018 and the replacement category Engineering Replacement.
No replacement catalog number is printed on the Rockwell page, so the route is an engineering substitution rather than a direct part-for-part swap.
Rockwell's own migration guidance for Bulletin 1746 I/O points to the Compact 5000 I/O platform with a Logix controller; a machine that stays on SLC 500 is served from the secondary market.
The enclosure, the terminal armature and the address assignment are unchanged when a card is replaced by the same catalog number, which is why the original number keeps a value after the end of sale.
A modular SLC 500 chassis reserves slot 0 for the processor or the adapter, so this card goes in any other I/O slot; a fixed controller chassis has a published power limit instead of a slot rule.
The backplane current above is added to the draw of every other card in the chassis and compared with the chassis supply before a card is added, which is the check that prevents an intermittent chassis fault after a retrofit.
Electro-optical isolation between the field terminals and the control logic is 1500V, and the operating range of the whole family is 0...60 °C with 5...95% noncondensing humidity and NEMA ICS 2-230 noise immunity.
The card in red in the table at the top is the one on this page.
What is 1746-IB8?
1746 SLC System, 8 ch-DC Input Module For Programmable Controller (sinking). 8 Point DC Input Module.
How many points does 1746-IB8 have?
8 inputs, 8 per common.
What voltage does 1746-IB8 work at?
24V DC signal input (sinking), operating range 10...30V DC (sinking).
Is 1746-IB8 still available?
Rockwell lists it as Discontinued with the discontinued date August 31, 2018, replacement category Engineering Replacement.
What has to be checked before fitting 1746-IB8?
The backplane current against the chassis supply, the sinking or sourcing convention of the field devices, and the terminal block, which is removable and often missing on a used card.