logo
Home ProductsAB SLC-500 Systems 1746

Allen Bradley PLC 1746-HT / 1746HT

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1746-HT / 1746HT

China Allen Bradley PLC 1746-HT / 1746HT supplier
Allen Bradley PLC 1746-HT / 1746HT supplier Allen Bradley PLC 1746-HT / 1746HT supplier Allen Bradley PLC 1746-HT / 1746HT supplier Allen Bradley PLC 1746-HT / 1746HT supplier Allen Bradley PLC 1746-HT / 1746HT supplier

Large Image :  Allen Bradley PLC 1746-HT / 1746HT

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1746-HT / 1746HT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $287.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1746-HT technical data PDF download 1746-HT IMC 110 Termination Panel

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: SLC 500 specialty module

1746-HT is the IMC 110 termination panel for the Allen-Bradley SLC 500: IMC 110 Termination Panel.

It is a specialty module, so the values below are the ones Rockwell publishes for this catalog number, and anything the publication does not print is marked not published.

1746-HSCE SLC 1 Channel High Speed Counter Module IN STOCK
1746-HSCE2 SLC 4 Channel High Speed Counter Module IN STOCK
1746-HSTP1 SLC 1 Axis Stepper Module IN STOCK
1746-BTM SLC Barrel Temperature Control Module IN STOCK
1746-BAS-T SLC High Speed BASIC Language Module IN STOCK
1746-INT4 SLC 4 Channel Isolated Thermocouple Module IN STOCK
1746-HCA IMC 110 to Terminal Panel Cable IN STOCK
1746-HT IMC 110 Termination Panel IN STOCK

Product Specifications 1746-HT (PDF)
 Application
 IMC 110 Termination Panel
 Cat Num
 1746-HT
 Brand Name
 Rockwell
 Product Type
 IMC 110 termination panel
 Origin
 Germany, per the Rockwell product data
 Lifecycle
 Discontinued
 Discontinued date
 March 6, 2025
 Replacement category
 No planned RA replacement

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-UM613 (module specifications) and 1746-UM613 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1746-HT original product photograph 1 1746-HT original product photograph 2 1746-HT original product photograph 3

What 1746-HT is

The 1746-HT is the termination panel for the IMC 110 motion controller. It is the terminal strip that the controller's cable lands on, so the field wiring stays in the panel when the controller is changed.

Technical data

Application: IMC 110 Termination Panel.

Cat Num: 1746-HT.

Brand Name: Rockwell.

Product Type: IMC 110 termination panel.

Origin: Germany, per the Rockwell product data.

Lifecycle: Discontinued.

Discontinued date: March 6, 2025.

Replacement category: No planned RA replacement.

Interface and configuration

The panel carries the screw terminals for the drive and feedback wiring and mates with the 1746-HCA cable assembly. Replacing the panel is a wiring job, so the terminal numbers have to be recorded before the old panel is removed.

The panel and cable are documented together in 1746-UM613, which is the only publication that defines the pinout of the pair.

Where it is used

It is a spare for an IMC 110 installation that is still in service; the controller family itself is long out of production, so the panel is bought to keep an existing machine running.

A slot-zero rule applies across the family: the module goes in any I/O slot except the processor slot, and its address follows the slot number.

Lifecycle and spares position

Rockwell lists 1746-HT as discontinued, date March 6, 2025, replacement category No planned RA replacement.

No replacement catalog number is printed on the Rockwell page for this number, so the route is an engineering substitution with the function re-implemented on a Logix platform.

Rockwell documents the module in 1746-UM613; that publication, not a distributor page, is the source for the values above.

FAQ — 1746-HT

What is 1746-HT?

IMC 110 Termination Panel. IMC 110 termination panel.

How many channels does 1746-HT have?

See the technical data table above.

Which slot does 1746-HT go in?

Any I/O slot except slot 0, which is reserved for the processor.

What isolation does 1746-HT provide?

Not published for this catalog number.

Is 1746-HT still available?

Rockwell lists it as discontinued, date March 6, 2025, replacement category No planned RA replacement.


Data sources. Technical values on this page come from Rockwell publication 1746-UM613 and the Rockwell product page for this catalog number. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1746 1746-HT in the SLC 500 system

1746-HT belongs to the SLC 500 modular hardware range. A SLC 500 modular system is a 1746 chassis with a power supply, a processor or an I/O adapter in the left-most slot, and I/O modules in the remaining slots.

The chassis sizes published in the SLC 500 selection guide are 4, 7, 10 and 13 slots, and a maximum of three chassis can be linked in one system. Where a catalog number falls outside those published sizes, its slot count has to be confirmed against current literature before it is quoted into a bill of materials.

Module density tops out at 32 channels per module in the 1746 range, and the chassis sizes are 4, 7, 10 and 13 slots. Open slots are closed with 1746-N2 card slot fillers, which matters because an unfilled slot changes the airflow and the mechanical retention of the modules around it rather than only the appearance of the rack.

SLC 500 processors span 1 K to 64 K of memory and can address up to 4096 inputs and 4096 outputs, and every modular processor except the SLC 5/01 can control remotely located I/O through a scanner. That distinction is what makes a 5/01 unsuitable as the head of a distributed system regardless of its I/O count.

Sizing a SLC 500 system is a fixed sequence, and it is the sequence rather than the arithmetic that stops most retrofits: count the I/O points, convert them into modules at the published channels per module, add a scanner or an adapter where the I/O sits remotely, total the 5V and 24V draws per chassis, choose the power supply that covers both totals, then choose the chassis with enough slots including fillers for the empties. Doing it in the reverse order, from a chassis that already exists, produces a system that fits mechanically and fails electrically.

Backplane budgeting is the arithmetic that decides whether a SLC 500 chassis closes: every module declares its 5V and 24V draw, the power supply declares its internal capacity for both rails, and the sum has to stay below both numbers at once. A chassis that passes on 5V and fails on 24V is the common mistake, because most digital I/O draws nothing from 24V while analog and thermocouple modules do.

Before ordering, confirm the slot count against the I/O list, confirm the 5V and 24V totals against the supply capacity rather than against the wattage, and confirm that the cable and the chassis are ordered separately, because none of these parts is included with any other.

Browse the Allen-Bradley SLC 500 1746 I/O modules category for the other models, options and spare parts that share this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)