Product Details:
Payment & Shipping Terms:
|
1746-HT is the IMC 110 termination panel for the Allen-Bradley SLC 500: IMC 110 Termination Panel.
It is a specialty module, so the values below are the ones Rockwell publishes for this catalog number, and anything the publication does not print is marked not published.
| 1746-HSCE | SLC 1 Channel High Speed Counter Module | IN STOCK |
| 1746-HSCE2 | SLC 4 Channel High Speed Counter Module | IN STOCK |
| 1746-HSTP1 | SLC 1 Axis Stepper Module | IN STOCK |
| 1746-BTM | SLC Barrel Temperature Control Module | IN STOCK |
| 1746-BAS-T | SLC High Speed BASIC Language Module | IN STOCK |
| 1746-INT4 | SLC 4 Channel Isolated Thermocouple Module | IN STOCK |
| 1746-HCA | IMC 110 to Terminal Panel Cable | IN STOCK |
| 1746-HT | IMC 110 Termination Panel | IN STOCK |
Application |
IMC 110 Termination Panel |
Cat Num |
1746-HT |
Brand Name |
Rockwell |
Product Type |
IMC 110 termination panel |
Origin |
Germany, per the Rockwell product data |
Lifecycle |
Discontinued |
Discontinued date |
March 6, 2025 |
Replacement category |
No planned RA replacement |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1746-UM613 (module specifications) and 1746-UM613 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The 1746-HT is the termination panel for the IMC 110 motion controller. It is the terminal strip that the controller's cable lands on, so the field wiring stays in the panel when the controller is changed.
Application: IMC 110 Termination Panel.
Cat Num: 1746-HT.
Brand Name: Rockwell.
Product Type: IMC 110 termination panel.
Origin: Germany, per the Rockwell product data.
Lifecycle: Discontinued.
Discontinued date: March 6, 2025.
Replacement category: No planned RA replacement.
The panel carries the screw terminals for the drive and feedback wiring and mates with the 1746-HCA cable assembly. Replacing the panel is a wiring job, so the terminal numbers have to be recorded before the old panel is removed.
The panel and cable are documented together in 1746-UM613, which is the only publication that defines the pinout of the pair.
It is a spare for an IMC 110 installation that is still in service; the controller family itself is long out of production, so the panel is bought to keep an existing machine running.
A slot-zero rule applies across the family: the module goes in any I/O slot except the processor slot, and its address follows the slot number.
Rockwell lists 1746-HT as discontinued, date March 6, 2025, replacement category No planned RA replacement.
No replacement catalog number is printed on the Rockwell page for this number, so the route is an engineering substitution with the function re-implemented on a Logix platform.
Rockwell documents the module in 1746-UM613; that publication, not a distributor page, is the source for the values above.
What is 1746-HT?
IMC 110 Termination Panel. IMC 110 termination panel.
How many channels does 1746-HT have?
See the technical data table above.
Which slot does 1746-HT go in?
Any I/O slot except slot 0, which is reserved for the processor.
What isolation does 1746-HT provide?
Not published for this catalog number.
Is 1746-HT still available?
Rockwell lists it as discontinued, date March 6, 2025, replacement category No planned RA replacement.