Product Details:
Payment & Shipping Terms:
|
The 1794-IB16 is the 16-point 24V DC sinking input module that carries most FLEX I/O digital input work: sixteen points in a single group, a selectable input filter per module, and one counter input that can be read as raw fast data.
It is the standard choice for a remote island of 16 switches, sensors or relay contacts, and the module most often paired with a 1794-IB16XOB16P on the same adapter when an island needs both directions.
| 1794-IB8 | 8-point 24V DC sinking input module | IN STOCK |
| 1794-IB16 | 16-point 24V DC sinking input module | IN STOCK |
| 1794-IB32 | 32-point 24V DC sinking input module | IN STOCK |
| 1794-IB10XOB6 | 10 inputs / 6 sourcing outputs, 24V DC combo module | IN STOCK |
| 1794-IB16XOB16P | 16 inputs / 16 protected sourcing outputs combo module | IN STOCK |
| 1794-IB16D | 16-point diagnostic sinking input module | IN STOCK |
| 1794-IB16XT | 16-point 24V DC sinking input, extended temperature | IN STOCK |
| 1794-IB10XOB6XT | 10 inputs / 6 sourcing outputs, extended temperature | IN STOCK |
| 1794-IA8 | 8-point 120V AC input module | IN STOCK |
| 1794-IA16 | 16-point 120V AC input module | IN STOCK |
| 1794-IC16 | 16-point 48V DC sinking input module | IN STOCK |
| 1794-IG16 | 16-point 5V DC TTL input module | IN STOCK |
| 1794-IH16 | 16-point 125V DC sinking input module | IN STOCK |
| 1794-IM8 | 8-point 240V AC input module | IN STOCK |
| 1794-IM16 | 16-point 240V AC input module | IN STOCK |
| 1794-IV16 | 16-point 24V DC sourcing input module | IN STOCK |
| 1794-IV32 | 32-point 24V DC sourcing input module | IN STOCK |
Application |
FLEX I/O digital input, 1794 terminal base |
Cat Num |
1794-IB16 |
Brand Name |
Rockwell |
Inputs |
16, current, sinking |
On-state voltage |
10V DC min, 24V DC nom, 31.2V DC max |
On-state current |
2.0 mA min, 8.0 mA nom, 12.0 mA max |
Off-state voltage |
5.0V DC max |
Input impedance |
4.6 kΩ nominal |
Input filter time |
0.25, 0.5, 1, 2, 4, 8, 16 or 32 ms selectable |
Isolation |
50V continuous basic; type tested 707V DC for 60 s |
Flexbus current |
30 mA at 5V DC |
Power dissipation |
6.1 W max at 31.2V DC (20.8 BTU/hr) |
Terminal base |
1794-TB3, -TB3S, -TB3K, -TB3SK, -TBKD, -TB37DS |
Weight |
74 g (2.61 oz) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
16 sinking inputs in one group. Signal lands on row A terminals 0...15, the sensor supply on row C 34...51 and the commons on row B 16...33, all internally connected.
Same thresholds as the eight-point module. On-state 10V DC minimum to 31.2V DC maximum at 24V DC nominal, on-state current 2.0 to 12.0 mA, off-state voltage 5V DC maximum, 4.6 kΩ nominal impedance.
Counted current. The module draws 30 mA from the 5V flexbus, so two of them cost the adapter less than one 32-point module's field power.
Both rows are internally bused, so sixteen sensors can run from one supply terminal pair — the convenience that costs per-channel supply separation.
The configuration word carries the counter bits as well, so writing the filter value and the counter bits in one word saves a second write at startup.
The counter reset bit clears the total from the program, so a shift totaliser can be re-zeroed without touching the field wiring.
SIL 2 covers the module inside a suitable architecture; the certificate does not turn a single-channel input into a safety function by itself.
The T4A North American code against T4 for IECEx reflects different assessment methods on the same hardware, not different temperature limits.
Eight settings from 0.25 ms to 32 ms. The filter is set in the output image word, not by a hardware switch, so it can be changed from the program during commissioning.
Short filters for position sensing, long filters for contacts. 0.25 ms catches a fast cam; 16 or 32 ms rejects contact bounce on a mechanical relay without adding a debounce timer in code.
Bits 0...2 cover inputs 0...11 and bits 12...15 cover inputs 12...15 on this module, which is why the configuration word looks asymmetric.
Input 15 can report a counter value alongside the normal input state, read as a second word from the module.
Fast or filtered. The counter-fast bit selects raw data for high-speed pulses, otherwise the filtered state is counted, which suits a totalising function rather than a motion axis.
Not available with Remote I/O adapters. The counter, reset and fast bits are unavailable when the island is driven by a 1794-ASB or 1794-ASB2 adapter, which is a real limit in a mixed retrofit.
TÜV certified for functional safety up to SIL 2 — this module is the one in the digital input range with that certificate, and it is the reason a safety-related input block sometimes settles on the 1794-IB16.
Ex ec IIC T4 Gc, DEMKO 14 ATEX 1342501X and IECEx UL 14.0066X for Zone 2 use, with the enclosure conditions that go with it (IP54 minimum, tool-access enclosure, transient protection at 140% of peak rated voltage).
UL listed for Class I Division 2 Groups A, B, C, D under file E194810, and the North American temperature code is T4A.
6.1 W maximum at 31.2V DC (20.8 BTU/hr) and 74 g, on any of the TB3 series bases with the keyswitch in position 2.
Indicators on the field side show each input state, which is why the module can be commissioned without a laptop on the bench.
<One base, three modules. The same 1794-TB3 family accepts the 8, 16 and 32-point inputs, so a spare base covers whichever card is fitted.
How many inputs has the 1794-IB16?
Sixteen, current sinking, in one group, with a selectable filter time per module.
Can the filter time be changed at runtime?
Yes. It is set in the output image word with eight settings from 0.25 ms to 32 ms.
Does it have a counter function?
Input 15 can report a counter value with counter-fast and counter-reset bits, but not when a 1794-ASB or 1794-ASB2 Remote I/O adapter drives the island.
Is the 1794-IB16 certified for functional safety?
Yes, TÜV certified up to and including SIL 2.
What is its isolation rating?
50V continuous basic insulation, type tested at 707V DC for 60 s between field side and system; no channel-to-channel isolation.
Which terminal base is used?
1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK, 1794-TBKD or 1794-TB37DS, keyswitch position 2.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley Flex I/O 1794 modules category.