Allen Bradley PLC 1794-IA8 / 1794IA8

China Allen Bradley PLC 1794-IA8 / 1794IA8 supplier
Allen Bradley PLC 1794-IA8 / 1794IA8 supplier Allen Bradley PLC 1794-IA8 / 1794IA8 supplier Allen Bradley PLC 1794-IA8 / 1794IA8 supplier Allen Bradley PLC 1794-IA8 / 1794IA8 supplier Allen Bradley PLC 1794-IA8 / 1794IA8 supplier

Large Image :  Allen Bradley PLC 1794-IA8 / 1794IA8

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-IA8 / 1794IA8

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $118.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-IA8 technical data PDF download FLEX I/O 1794-IA8 / 1794IA8 8-Point 120V AC Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-IA8 reads eight 120V AC field signals directly, with no interposing relay and no separate field supply: the AC voltage that operates the sensor is the input.

It is the card for panels that already switch 120V AC — limit switches, float switches, motor starter auxiliary contacts and old relay logic that nobody intends to rewire to 24V DC.

1794-IA8 8-point 120V AC input module IN STOCK
1794-IA8I 8-point 120V AC input module, 1240V isolation IN STOCK
1794-IA16 16-point 120V AC input module IN STOCK
1794-IA16K 16-point 120V AC input module, conformal coated IN STOCK
1794-IM8 8-point 240V AC input module IN STOCK
1794-IM16 16-point 240V AC input module IN STOCK
1794-OA8 8-point 120V AC output module IN STOCK
1794-OA8I 8-point 120V AC isolated output module IN STOCK
1794-OA8K 8-point 120V AC output module, conformal coated IN STOCK
1794-OA16 16-point 220V AC output module IN STOCK
1794-OA16K 16-point 220V AC output module, conformal coated IN STOCK
1794-OM8 8-point 240V AC output module IN STOCK
1794-OM16 16-point 240V AC output module IN STOCK

Product Specifications 1794-IA8 (PDF)
 Application
 FLEX I/O digital input, 1794 terminal base
 Cat Num
 1794-IA8
 Brand Name
 Rockwell
 Inputs
 8, AC
 Input voltage
 120V AC nominal
 On-state voltage
 65V AC minimum
 Off-state voltage
 43V AC maximum
 Input current
 12 mA at 120V AC, 60 Hz
 Input impedance
 10.6 kOhm
 Input filter
 8.4...40 ms off to on, 26.4...58 ms on to off
 Isolation
 1250V AC for 60 s, field to system
 Power dissipation
 4.5 W at 132V AC (15.3 BTU/hr)
 Terminal base
 1794-TBN, -TBNK, -TB2, -TB3, -TB3S, -TB3K, -TB3SK, -TBKD
 Operating temperature
 -20...55 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-IA8 original product photograph, wide view 1794-IA8 original product photograph, wide view 1794-IA8 original product photograph, wide view

Why an AC input card exists

Thresholds are set for 120V AC: 65V AC minimum to read on and 43V AC maximum to read off, with 12 mA drawn at 120V AC and a 10.6 kOhm input impedance.

No external supply for the field circuit. The sensor voltage is the signal, so a legacy 120V control circuit needs no 24V rail added to the panel.

A 120V AC proximity switch or a mechanical limit switch wired to this card needs no relay, no opto-isolator board and no second power supply.

Input impedance is the load on the switch. At 10.6 kOhm the card draws 12 mA, which is within the rating of a standard 120V limit switch but not of a low-current solid-state sensor.

Leakage through a solid-state switch can hold a channel on if the leakage exceeds the drop across the input impedance; a bleeder resistor is the usual field remedy.

Filtering

The input filter is selectable from 8.4 to 40 ms off to on, with 26.4 to 58 ms on to off, set per module from the adapter or the controller.

Long filtering rejects contact bounce from a mechanical limit switch, at the cost of a slower response to a genuine short pulse.

Short filtering catches a fast pulse but lets line noise through; on a 120V AC circuit the noise source is usually a contactor coil on the same feed.

Filtering happens in the module, so the response time is the same whether the island is on ControlNet, EtherNet/IP or a Remote I/O adapter.

One setting serves all eight channels; a mixed panel, half mechanical and half solid-state, is easier to split across two modules than to compromise on one filter time.

Isolation and supply

1250V AC for 60 s is the field-to-system isolation, type tested, and there is no channel-to-channel isolation.

Logic power comes from the adapter over the FlexBus, so the module adds no field supply load; its 4.5 W at 132V AC is heat the enclosure has to remove.

Channels share a common. A grounded sensor on one channel puts that ground on the common of all eight, which is why the AC input common is normally left floating in the panel.

At 132V AC the dissipation is 4.5 W (15.3 BTU/hr), the figure Rockwell prints for the worst-case line voltage rather than nominal.

Terminal base choice

Eight bases carry the module: 1794-TBN, -TBNK, -TB2, -TB3, -TB3S, -TB3K, -TB3SK and -TBKD, with the K suffix denoting the knife-disconnect version.

1794-TBN and -TBNK are the bases with fused terminals, which is how a 120V AC input circuit gets its field protection without a separate fuse block.

Choice of screw, spring or cage clamp follows the panel standard; a knife-disconnect base lets one channel be isolated for a live test without removing a wire.

The base, not the module, holds the field terminals, so replacing an input card leaves every wire in place — worth planning at the base-selection stage, not at commissioning.

Commissioning notes

Check the field voltage first. An AC input reads on above 65V AC, so a 120V circuit that has dropped to 60V through a long cable run will read off and look like a failed card.

The eight channel LEDs are yellow on FLEX I/O input modules and show the filtered state, not the raw terminal voltage.

Keying is set before insertion. The module and base carry a mechanical key that must match; forcing a module into the wrong key position damages the FlexBus connector.

Mounting is five steps: set the key, push the FlexBus connector fully left, inspect the bottom pins, align the module with the base groove, then press until the latch locks.

-20...55 deg C operating range and the general FLEX I/O environmental ratings (5 g vibration at 10...500 Hz, 30 g shock) cover a normal cabinet; a cold outdoor panel needs the XT variant.

FAQ — 1794-IA8

How many inputs has the 1794-IA8?

Eight 120V AC inputs, 12 mA at 120V AC, 60 Hz, with a 10.6 kOhm input impedance.

What are the on and off thresholds?

65V AC minimum to read on and 43V AC maximum to read off, at a 120V AC nominal input.

Can the filter time be changed?

Yes, per module: 8.4...40 ms off to on and 26.4...58 ms on to off, selected in the adapter or controller configuration.

Is a field supply needed for the inputs?

No. The 120V AC field voltage is the signal; the module's logic power comes from the adapter over the FlexBus.

Which terminal bases fit the 1794-IA8?

1794-TBN, -TBNK, -TB2, -TB3, -TB3S, -TB3K, -TB3SK and -TBKD.

What isolation does it provide?

1250V AC for 60 s field to system, type tested; there is no isolation between channels.


Data sources. Technical values on this page come from Rockwell publication 1794-SG002 (FLEX I/O Selection Guide, Table 7 and Table 10) and 1794-IN093. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

The Allen-Bradley Flex I/O 1794 modules category groups the other catalog numbers, options and spare parts in the same range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)