Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-ACNR15XT / 1794ACNR15XT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $545.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-ACNR15XT technical data PDF download 1794-ACNR15XT FLEX I/O-XT Redundant ControlNet Adapter

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-ACNR15XT is the extended-range redundant ControlNet adapter: two BNCs, 8 modules, and a -25...70 deg C rating instead of -25...55 deg C.

The surrounding air maximum rises to 70 deg C, which is what makes the part usable in skid-mounted or unventilated cabinets where the standard adapter derates out.

1794-AENT EtherNet/IP adapter, single RJ45, 8 modules IN STOCK
1794-AENTR dual-port EtherNet/IP adapter, redundancy capable IN STOCK
1794-AENTRXT dual-port EtherNet/IP adapter, extended temperature IN STOCK
1794-ACN15 ControlNet adapter, 5 Mbps, 8 modules IN STOCK
1794-ACN15K ControlNet adapter, 5 Mbps, conformal coated IN STOCK
1794-ACNR ControlNet adapter with redundant media IN STOCK
1794-ACNR15XT ControlNet adapter, redundant media, extended temperature IN STOCK
1794-ACN ControlNet adapter module, 8 modules IN STOCK
1794-ADN DeviceNet adapter, 8 modules IN STOCK
1794-ADNK DeviceNet adapter, conformal coated IN STOCK
1794-APB Profibus DP adapter, 8 modules IN STOCK
1794-APBDPV1 Profibus DP-V1 adapter, 8 modules IN STOCK
1794-ASB Remote I/O adapter, 8 modules IN STOCK
1794-ASB2 Remote I/O adapter, extended functionality IN STOCK
1794-ASBLT Remote I/O adapter with built-in termination IN STOCK

Product Specifications 1794-ACNR15XT (PDF)
 Application
 FLEX I/O-XT redundant ControlNet adapter
 Cat Num
 1794-ACNR15XT
 Brand Name
 Rockwell
 I/O module capacity
 8 modules
 ControlNet connectors
 2 x BNC (A and B)
 Supply voltage, input
 19.2...31.2V DC, 400 mA
 Supply voltage, output
 5V DC, 640 mA
 Communication rate
 5 Mbps
 Coating
 Conformal coated
 Dimensions
 87.4 x 94 x 92 mm
 Operating temperature
 -25...70 deg C

Same-family catalog numbers: 1794-ACN15, 1794-ACN15K, 1794-ACNR, 1794-ACNR15XT. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1794 family.

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-ACNR15XT original product photograph, wide view 1794-ACNR15XT original product photograph, wide view 1794-ACNR15XT original product photograph, wide view

Range

-25...70 deg C operating and 70 deg C maximum surrounding air, per 1794-IN128.

Conformal coating on the assembly, matching the -XT module and base family.

Same 2 BNC redundant media pair, connectors A and B.

Same 5 Mbps, 8-module capacity as the standard redundant adapter.

Power

19.2...31.2V DC at 400 mA input requirement.

5V DC 640 mA Flexbus output.

14 A for 2 ms inrush.

22...12 AWG single or 22...16 AWG double wire, 105 deg C insulation rating.

Mechanical

87.4 x 94 x 92 mm, 220 g, unchanged from the standard redundant part.

-40...85 deg C nonoperating range, 5...95 percent noncondensing humidity.

30 g operating shock, 50 g nonoperating shock.

Belden RG-6/U ControlNet cable is the specified medium.

Application

Outdoor and skid-mounted ControlNet islands.

Redundant media plus wide temperature in one part.

Not for EtherNet/IP; the 1794-AENTRXT is the equivalent there.

Not for single-cable segments.

Where it fits

-XT FLEX I/O islands on ControlNet.

Panels needing redundancy and 70 deg C ambient.

Not 16 modules; capacity stays at 8.

Not a media converter.

Same node address on both BNCs, which is why one island keeps one ControlNet address across the redundant pair.

FAQ — 1794-ACNR15XT

What is the operating range of the 1794-ACNR15XT?

-25...70 deg C with 70 deg C maximum surrounding air.

How many BNC ports has it?

Two, connectors A and B, for redundant media.

What is the ControlNet rate?

5 Mbps over Belden RG-6/U cable.

How many modules can it carry?

8 FLEX I/O modules.

What is the supply requirement?

19.2...31.2V DC at 400 mA, 14 A inrush for 2 ms.

Is it coated?

Yes, conformally coated for the -XT environment.


Data sources. Technical values on this page come from Rockwell publication 1794-IN128 (FLEX I/O ControlNet Adapters). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1794-ACNR15XT: FLEX I/O ControlNet redundant adapter, extended temperature

All values on this page are taken from Rockwell Automation publications 1794-IN101 (Series B) and 1794-IN128F-EN-P (Series D) for the FLEX I/O ControlNet adapter modules. Where the two series differ, both figures are shown rather than merged.

The 1794-ACNR15XT is the redundant-media ControlNet adapter rated for a hotter cabinet. Functionally it is the ACNR15: two BNC ports, one node address, eight I/O modules, 5 Mbps. The XT suffix buys temperature headroom, and that is the entire reason to pay for it.

The published ratings make the difference explicit. Both parts operate from -25 °C; the standard adapter stops at +55 °C with a 55 °C maximum surrounding air, while the XT version runs to +70 °C with a 70 °C maximum surrounding air. Everything else in the environmental table is shared: -40...+85 °C non-operating, 5...95% relative humidity non-condensing, 5 g vibration at 10...500 Hz, 30 g operating shock, 50 g non-operating shock.

That 15 °C of headroom is worth having in a sealed enclosure without forced ventilation, in a panel mounted against a furnace wall, or in a skid that travels between climates. It is not a licence to exceed the enclosure rating: the adapter is still open-style equipment that must sit inside a tool-accessible enclosure, and Zone 2 use still needs at least IP54 with pollution degree 2.

Electrically the XT follows Series D: 19.2...31.2 V DC input at 400 mA, 640 mA at 5 V DC to the backplane, 14 A inrush for 2 ms, 3.4 W maximum dissipation at 19.2 V, 50 V continuous isolation with an 860 V AC type test, and no isolation between the two ControlNet channels. Dimensions are 87.4 x 94 x 92 mm and the unit weighs 220 g.

Certification is where the XT part is easiest to get wrong on a submittal. IECEx UL 14.0066 covers ACNR15 and ACNR15XT; the ATEX marking is II 3G Ex nA IIC T4 Gc under LCIE 01 ATEX 6020 X and DEMKO 14 ATEX 1342501X. The single-media 1794-ACN15 does not carry the IECEx listing, so a project that specifies IECEx for the whole slice cannot substitute the single adapter into a redundant position.

Field wiring is the standard adapter pattern: -V common on C, +V DC on D, -V and +V pass-through on E and F, 0.8 N*m (7 lb-in) torque, 10 m maximum power run, two conductors maximum per terminal, and 22...12 AWG single or 22...16 AWG double conductor at 75 °C minimum.

Specifications printed by Rockwell

AttributeValue
I/O capacity8 FLEX I/O modules on the backplane
Input power19.2...31.2 V DC, 400 mA (Series D) / 450 mA maximum, 330 mA at 24 V (Series B)
Backplane output5 V DC, 640 mA maximum
Inrush14 A for 2 ms (Series D); 23 A for 2 ms (Series B)
Communication rate5 Mbps ControlNet
Isolation50 V continuous, basic insulation; type tested 860 V AC for 60 s power to system, power to ControlNet and ControlNet to system (Series D). No isolation between ControlNet channels.
Power dissipation3.4 W maximum at 19.2 V DC (Series D); 4.6 W maximum at 19.2 V DC (Series B)
Terminal torque0.8 N*m (7 lb-in) on terminals C, D, E, F
Wire sizeSingle wire 0.33...2.5 mm2 (22...12 AWG); double wire 0.33...1.3 mm2 (22...16 AWG, not intermixed); 75 °C rated, 1.2 mm insulation maximum
Dimensions87.4 x 94 x 92 mm (3.44 x 3.7 x 3.6 in.), Series D; 87 x 94 x 69 mm (3.4 x 3.7 x 2.7 in.), Series B
Weight220 g (7.76 oz)
Operating temperature-25...+55 °C for 1794-ACN15 and 1794-ACNR15; -25...+70 °C for 1794-ACNR15XT

Installation facts that decide field failures

  • Backplane. The adapter is the head of the slice: its Flexbus connector drives up to eight terminal bases, and the base hook on the right rear of the adapter has to engage the notch on the first base or the backplane connection is not mechanically locked.
  • Node address. Node addressing is set on the two-dial switch, valid range 01...99. The dials are read by RSNetWorx for ControlNet; a duplicate address shows up as the Comm A and Comm B LEDs flashing red/off alternately, not as a comms failure on one channel.
  • Field power. Field power lands on terminals C (-V common, upper connector) and D (+V DC, lower connector); E and F pass -V common and +V DC to the next module in the series. Series D limits the power wiring run to 10 m (32.8 ft); the earlier Series B publication stated 3 m (9.8 ft), so a panel wired to the older limit is still inside specification.
  • Grounding. Grounding is through the DIN rail: the rail must be zinc-plated chromate-passivated steel, secured about every 200 mm, with end anchors, because the adapter has no separate chassis terminal.
  • Indicators. The Status LED tells the maintenance story: off means no power, flashing green means on-line but not connected, solid green means connected, flashing red means an I/O module was removed or a wrong module was inserted or a flash update is in progress, solid red means adapter failure.
  • Supply source. Series D adds an electrical safety requirement that the earlier publication does not state: the 24 V source feeding the adapter and all connected I/O must be a SELV or PELV supply approved to EN/IEC 60950-1, EN/IEC 61010-2-201 or EN/IEC 62368-1, and the field wiring must follow the applicable installation code such as NEC article 501-4(b) in Class I locations.
  • Hazardous area. Zone 2 use requires an enclosure of at least IP54, pollution degree 2, transient excursions held to 140% of the peak rated voltage, and the ATEX marking II 3G Ex nA IIC T4 Gc (LCIE 01 ATEX 6020 X). The redundant adapters also carry DEMKO 14 ATEX 1342501X and IECEx UL 14.0066.

Mounting follows the same sequence as the terminal bases: hook the rear lip on a 35 x 7.5 x 1 mm top-hat rail (199-DR1 / EN 50022), rotate onto the rail, press down until the locking tab snaps, then push the Flexbus connector into the adapter. The first terminal base hooks into the notch on the right rear of the adapter, and that mechanical link is what keeps the backplane connection from opening under vibration.

Panel or wall mounting uses the 1794-NM1 mounting kit, covered by a separate installation instruction rather than by the adapter publication.

This part sits in the Allen-Bradley Flex I/O 1794 modules category, with the other models and spare parts listed alongside it.