|
Product Details:
Payment & Shipping Terms:
|
The 1794-OF4IXT is the extended-temperature isolated analog output: four channels, six ranges, sub-25 us step response, rated -20...70 deg C with Class G3 coating.
It keeps the feature that matters most in a mixed cabinet — channel-to-channel isolation — while widening the ambient range by 15 deg C over the standard OF4I.
| 1794-IE8 | 8-channel analog input module | IN STOCK |
| 1794-IE8XT | 8-channel analog input module, extended temperature | IN STOCK |
| 1794-IE8H | 8-channel HART analog input module | IN STOCK |
| 1794-IE12 | 12-channel analog input module | IN STOCK |
| 1794-IE12K | 12-channel analog input module, conformal coated | IN STOCK |
| 1794-IF4I | 4-channel isolated analog input module | IN STOCK |
| 1794-IF4IXT | 4-channel isolated analog input, extended temperature | IN STOCK |
| 1794-IF4ICFXT | 4-channel isolated analog input, conformal coated | IN STOCK |
| 1794-IF8IH | 8-channel HART isolated analog input module | IN STOCK |
| 1794-IR8 | 8-channel RTD input module | IN STOCK |
| 1794-IRT8 | 8-channel thermocouple/RTD input module | IN STOCK |
| 1794-IRT8XT | 8-channel thermocouple/RTD input, extended temperature | IN STOCK |
| 1794-IT8 | 8-channel thermocouple/mV input module | IN STOCK |
| 1794-IE8XOE4 | 8-input, 4-output analog combination module | IN STOCK |
| 1794-IE4XOE2 | 4-input, 2-output analog combination module | IN STOCK |
| 1794-IF2XOF2I | 2-input, 2-output isolated analog combination module | IN STOCK |
| 1794-OE4 | 4-channel analog output module | IN STOCK |
| 1794-OE12 | 12-channel analog output module | IN STOCK |
Application |
FLEX I/O-XT isolated analog output |
Cat Num |
1794-OF4IXT |
Brand Name |
Rockwell |
Channels |
4, channel-to-channel isolated |
Output ranges |
4...20 mA, 0...20 mA, +/-10V, 0...10V, +/-5V, 0...5V |
Resolution |
15 bits plus sign |
Step response |
Under 25 us to 63% of full scale |
Accuracy |
0.1% of full scale at 25 deg C |
Isolation |
1500V AC for 60 s channel to channel |
Coating |
Conformal coated to ISA Class G3 |
Operating temperature |
-20...70 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
-20...70 deg C, against -20...55 deg C on the standard module.
Channel-to-channel isolation at 1500V AC for 60 s and 2550V DC for 1 s type test.
120V continuous channel isolation with TB2, TB3, TB3S or TB3T bases; 250V with a TBN base.
Class G3 conformal coating on the assembly.
Six ranges from 4...20 mA to plus/minus 10V, configurable per channel.
15 bits plus sign at 0.656 uA and 0.320 mV per count.
Under 25 us to 63% of full scale, conversion at 2.5 or 5.0 ms for all channels.
0...750 Ohm on current, 3 mA maximum on voltage.
210 mA at 24V DC module consumption.
4.7 W at 31.2V DC and 16 BTU/hr, add it to the enclosure budget.
0.1% of full scale at 25 deg C, 0.0025% per deg C current drift and 0.0012% voltage drift.
Factory calibrated, no trim procedure.
Hot cabinets driving proportional valves or drive references.
Loops needing channel-to-channel isolation at 70 deg C ambient.
Not a non-isolated card; the OE4 family is cheaper where isolation is not needed.
Not for 8 channels.
Same base family as the OF4I, so existing spares stay compatible.
Coating covers the module, not the base: pair with a coated base for a coated island.
<Not a HART output.
Not SIL rated.
What is the operating range of the 1794-OF4IXT?
-20...70 deg C with Class G3 coating.
How many channels has it?
4, channel-to-channel isolated.
What ranges are available?
4...20 mA, 0...20 mA, plus/minus 10V, 0...10V, plus/minus 5V and 0...5V.
What is the step response?
Under 25 us to 63% of full scale.
What is the channel-to-channel isolation?
1500V AC for 60 s type tested.
What is the module current?
210 mA at 24V DC, 4.7 W dissipation at 31.2V DC.
1794-OF4IXT is the extended temperature, conformally coated version of the FLEX I/O four channel isolated analog output module, and the figures below come from the FLEX I/O-XT installation publication rather than from a distributor summary.
| Specification | Value |
|---|---|
| Catalog number | 1794-OF4IXT, FLEX I/O-XT isolated analog output module, extended temperature and conformally coated |
| Outputs | 4 isolated analog outputs |
| Resolution | 15 bits plus sign, 0.320 mV per count on voltage, 0.656 microamps per count on current |
| Output ranges | 4 to 20 mA, 0 to 20 mA, plus or minus 10V, 0 to 10V, plus or minus 5V, 0 to 5V, all configurable per channel |
| Data formats | Signed twos complement, signed twos complement percent, binary, offset binary |
| Update rate | 2.5 ms or 5.0 ms for all channels depending on the configured range |
| Conversion type | Digital to analogue converter |
| Step response | Under 25 microseconds to 63 percent of full scale |
| Accuracy | 0.1 percent of full scale at 25 degrees C; drift 0.0012 percent per degree C on voltage and 0.0025 percent per degree C on current |
| Load limits | Voltage output 3 mA maximum current load; current output 0 to 750 Ohms resistive |
| Unconfigured state | 0 mA or 0V output until the module is configured |
| Isolation | 120V continuous with the 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T or 1794-TB3TS base; 250V continuous with the 1794-TBN; type tested at 1500V AC for 60 s |
| Terminal bases | 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS, 1794-TBN |
| Operating temperature | Minus 20 to 70 degrees C as an XT module, with conformal coating |
| Source | 1794-IN129 FLEX I/O-XT isolated analog input and output modules, and 1794-SG002D-EN-P for the isolation by base type |
Fifteen bits plus sign over a five volt span is three hundred and twenty microvolts per count, and over a twenty milliamp span it is six hundred and fifty six nanoamps per count. The accuracy of one tenth of a percent of full scale is looser than that step size, so the last digits of the commanded value are finer than the loop can verify.
The output holds zero until the module is configured. That is a deliberate behaviour for a valve or a drive reference, because an unconfigured channel commands a known zero instead of a stale value from a previous download.
Isolation depends on the terminal base, not on the module alone: one hundred and twenty volts continuous on the TB2 and TB3 family, two hundred and fifty volts on the TBN. A loop that needs the higher figure is a base selection decision before the module is ordered.
This page states only what the Rockwell FLEX I/O documentation publishes for 1794-OF4IXT: the catalog identity, the published rating or dimension, the compatibility statement and the source publication. Where the manufacturer does not publish a figure, the page says so instead of estimating one.
Labels matter more than they look. A terminal base that is not marked with its slot and its module type turns every future maintenance visit into a wire tracing exercise, which is exactly what the label kit exists to prevent.
Accessory part numbers are frequently the difference between a system that ships and a system that waits. A missing extender cable is a one week delay on a panel that is otherwise complete, and the order of magnitude of that delay belongs in the planning conversation.
A dummy filler module exists because an empty terminal base is an open slot in the flexbus chain. The filler carries no electronics, and its whole job is mechanical and documentation: the rail is complete, the slot is accounted for, and the drawing shows an intentional gap rather than a missing part.
Country of origin and part number structure belong on the page because procurement asks. A conformally coated variant and a standard variant share the same mechanical drawing and differ in the suffix, which is the kind of detail that only shows up at goods receipt.
Accessories are where a FLEX system stops being a catalog page and becomes a panel. The rail, the extender cable, the mounting screws and the filler module all change the drawing, and none of them appear in the module data sheet that the integrator reads first.
Screws in a mounting kit are a count, not a suggestion. Two for the adapter and two for each module means the kit covers a full eight module group, and a ninth module requires either a second kit or a sourced screw, which is a purchasing detail worth stating.
The flexbus connector is the fragile part of the assembly. It is pushed to the left to connect and retracted to disconnect, and a base installed with the connector partly extended will produce intermittent I/O that survives a power cycle and reappears under vibration.
A right angle split between horizontal and vertical orientation is the real reason the extender exists. Mounting the adapter horizontally in a shallow enclosure and the modules vertically in a deeper section is a mechanical decision that the cable makes possible without a second adapter.
Temperature ratings on a passive accessory are inherited from the materials. A cable rated to sixty degrees limits the panel interior temperature just as firmly as a module rated to fifty five, and a hot enclosure will fail the cable before it fails the electronics.
Every accessory on this page is sourced from the same FLEX selection guide that specifies the adapters and the terminal bases, which means the compatibility statement is the manufacturer statement rather than a distributor inference.
Panel mounting without DIN rail is a common requirement in machine tools exported to regions where the rail is not standard, and the mounting kit with its screws is cheaper than a rail plus the labour to fit it.
A filler is not a spare slot. Some integrators install a filler to reserve capacity for a later expansion, and that works only if the adapter was sized for the eventual module count at commissioning time, not at expansion time.
The extender cable rule is one per system, not one per row. A second extender in series breaks the flexbus timing assumptions the adapter was designed around, so the two row layout is a one cable layout, and a three row layout is not supported at all.
Configure the range and the data format before the loop is commissioned, choose the base for the isolation figure the loop needs, and remember that the output sits at zero until configured.
The Allen-Bradley Flex I/O 1794 modules category groups the other catalog numbers, options and spare parts in the same range.