Product Details:
Payment & Shipping Terms:
|
The 1794-TB3G is the grounded screw-clamp base: 36 I/O terminals, 2 common, 2 +V and 10 chassis ground, for analog modules that need individual grounding.
Ten chassis ground terminals in one base is what an analog card wants — one ground reference per signal pair rather than a shared return, which is where shield and common practice meet.
| 1794-TB2 | 16-terminal cage clamp base, 2-wire, up to 132V AC | IN STOCK |
| 1794-TB3 | 16-terminal cage clamp base, 3-wire devices | IN STOCK |
| 1794-TB3S | 16-terminal spring clamp base, 3-wire devices | IN STOCK |
| 1794-TB32 | 32-terminal cage clamp base for 32-point modules | IN STOCK |
| 1794-TB32S | 32-terminal spring clamp base for 32-point modules | IN STOCK |
| 1794-TB3T | temperature base with two cold junction compensation sets | IN STOCK |
| 1794-TB3TS | spring clamp temperature base with CJC sets | IN STOCK |
| 1794-TB3G | grounded screw clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TB3GS | grounded spring clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TBKD | cage clamp base with 16 knife disconnects | IN STOCK |
| 1794-TBN | NEMA-style screw clamp base, up to 264V AC/DC | IN STOCK |
| 1794-TBNF | fused NEMA-style base, eight 5 x 20 mm fuses | IN STOCK |
| 1794-TB37DS | 37-pin D-shell termination for digital and analog modules | IN STOCK |
| 1794-TB62DS | 62-pin D-shell termination for digital and analog modules | IN STOCK |
Application |
FLEX I/O grounded terminal base for analog modules |
Cat Num |
1794-TB3G |
Brand Name |
Rockwell |
Termination |
Grounded screw clamp, 36 I/O, 2 common, 2 +V, 10 chassis ground |
Wire size |
0.21...1.3 mm2 (24...16 AWG) stranded, 105 deg C or greater |
Current capacity |
10 A maximum |
Dimensions |
94 x 94 x 69 mm |
Operating temperature |
-20...70 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
36 I/O, 2 common, 2 +V and 10 chassis ground terminals, a different distribution from the digital bases: more signals, fewer power terminals, more grounds.
Individual grounding is the point: the selection guide lists this base for certain analog modules where the screen and the return have to be separated.
10 A maximum current capacity, and 24...16 AWG stranded wire rated 105 deg C or greater.
Grounded screw clamp, so the termination is a screw and the ground bond is part of the base rather than a separate terminal block.
Analog modules that need a ground per channel, which the standard 1794-TB3 does not provide.
Shielded analog cable lands on the chassis ground terminals, keeping the shield at the panel rather than at the field device.
-20...70 deg C operating range allows it on an -XT analog island.
The spring clamp equivalent is the 1794-TB3GS; the coating versions add K to the catalog number.
Not a 16-point digital base: the 36 I/O terminals are for analog channel density, and the 2 common terminals will not serve a 16-point output card.
Wire window 24...16 AWG is narrower than the 1794-TB3's 22...12 AWG, which matters on a retrofit with heavier existing conductors.
94 x 94 x 69 mm keeps the same rail footprint.
Current capacity stays at 10 A, the family figure.
35 x 7.5 mm DIN rail with 25 mm air space around the system.
A zinc-plated, yellow-chromated steel rail is required for the chassis ground path through the rail; a poor rail material defeats the grounding this base is bought for.
1794-NM1 panel-mount kit uses mounting screws with star washers to keep the chassis ground through shock and oxidation.
1492-EA35 rail locks for high-vibration or vertical mounting.
Analog input and output islands with shielded field cable.
Panels where each channel's return is grounded individually, not commoned.
Not for digital 16-point cards; use the 1794-TB3 or 1794-TB3S.
Not for thermocouple CJC; the 1794-TB3T carries the CJC sets.
How many terminals has the 1794-TB3G?
36 I/O, 2 common, 2 +V and 10 chassis ground, in a grounded screw clamp.
Why choose it over the 1794-TB3?
It provides individual grounding for analog modules and ten chassis ground terminals.
What wire size does it accept?
0.21...1.3 mm2 (24...16 AWG) stranded, 105 deg C or greater.
Is there a spring clamp version?
Yes, the 1794-TB3GS; the K versions add conformal coating.
What current can it carry?
10 A maximum.
What rail does it need?
35 x 7.5 mm zinc-plated, yellow-chromated steel DIN rail for chassis grounding.
1794-TB3G is a FLEX I/O terminal base unit, not an I/O module. It is the part that carries the field terminals, plugs into the adjacent base to form the backplane, and holds the module on top. The termination type here is Grounded screw clamp with 36 I/O, 2 common, 2 +V, 10 chassis ground.
| Attribute | Value |
| Catalog number | 1794-TB3G |
| Termination type | Grounded screw clamp |
| Connections | 36 I/O, 2 common, 2 +V, 10 chassis ground |
| Current capacity, maximum | module dependent |
| Wiring category | module dependent |
| Field voltage | Per module |
| Operating temperature | -20...+70 C |
| Purpose in the range | A screw clamp base with individual grounding, used with certain analog modules. |
The conductor range for this base is 0.34 to 3.3 mm2 (22 to 12 AWG) solid or stranded copper rated 75 C or greater, with 1.2 mm maximum insulation, with a maximum current capacity of module dependent across the base. Those figures are the base rating and not the module rating: a 16 point module on a 10 A base is still limited by the module output current per channel.
Selecting a base is a compatibility step, not a preference step. The module data sheet names the bases that are permitted for it, and a base outside that list may key differently, may not carry the required common and voltage terminals, or may not be rated for the field voltage of the module.
The wiring category matters as much as the gauge: category 2 bases are the general field wiring class, while grounded bases in the 1794-TB3G family carry 10 chassis ground terminals for analog and temperature modules where a separate signal common is needed.
For a retrofit into an existing slice, the addressing is decided by position rather than by catalog number: FLEX I/O assigns the module its place in the rack by the order of the bases on the rail, so inserting a module in the middle shifts the addresses of everything to its right and requires the program to be re-checked.
FLEX I/O bases and modules are separate line items on a purchase order, and the price of getting that wrong is a second shipment: a module without its base cannot be installed, and a base of the wrong termination type cannot be reworked in the field because the module keys to the base family.
The 22 to 12 AWG acceptance range on the standard bases is wider than the field device terminals in most panels, so the practical constraint is usually the device end, not the base end. Where a 24V DC sensor cable is 18 AWG and the base accepts 12 AWG, the conductor still has to be torqued to the published value rather than to feel.
Conformal coating on a K suffix base is applied to the assembled board and not to the terminals, so the coating protects the electronics against condensation while the field terminals remain serviceable. That is the point of ordering the coated base instead of sealing the whole enclosure.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
Related models, options and spare parts for this range are listed in the Allen-Bradley Flex I/O 1794 modules category.