1771-IT is a 8-point fast response DC input module for the 1771 I/O chassis used by PLC-5 and PLC-2 processors. Fast response is the whole purpose of this card: it is the input used for a pulse or a registration mark that a standard filtered input would stretch past recognition.
Field connections land on the 1771-WA wiring arm, the 10-terminal arm that swings up to the module so the arm can stay wired while the module is swapped.
Catalog number |
1771-IT |
Product type |
8-point fast response DC input module |
Number of inputs |
8 |
Input signal |
DC, fast response |
Module series |
A |
1771 chassis compatibility |
Series A and B chassis |
Lifecycle status |
Discontinued |
Discontinued date |
Not published |
Replacement category |
Engineering Replacement |
UPC |
Not published |
Country of origin |
Not published |
Field wiring arm |
1771-WA, 10 terminal |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publication 1771-TD180 (module specifications) and the Rockwell literature library (installation instructions).
1771-IT is a 8-point fast response DC input module for the 1771 I/O chassis used by PLC-5 and PLC-2 processors. Fast response is the whole purpose of this card: it is the input used for a pulse or a registration mark that a standard filtered input would stretch past recognition.
The slot it occupies is one 1771 slot, and the input image it claims is fixed by the module series: 8. That number decides how much of the processor input table the rack consumes, not how many wires the panel brings in.
Signal level is DC, fast response. Nothing in the module is software configurable, so the field device has to match the printed range before the module is ordered.
Field connections land on the 1771-WA wiring arm, the 10-terminal arm that swings up to the module so the arm can stay wired while the module is swapped.
Keying bands in the chassis connector must line up with the slots on the module board. 1771 chassis are keyed per module type precisely so a 120 V AC module cannot be pushed into a slot wired for a 24 V DC module.
Backplane current comes from the chassis supply, so the load of every module in the rack has to be added up before a rack is repopulated with these cards.
Published compatibility: image bits 8, module series A, unrestricted placement in both chassis series.
Chassis compatibility is published per module series: Series A and B chassis. Series A modules fit the superseded 1771-A1, -A2 and -A4 chassis as well as the current A1B to A4B and AM1/AM2 chassis.
Some 32-point and isolated cards can only be placed under 1-slot or 2-slot addressing rules, so the addressing mode of the chassis has to be confirmed before a mixed rack is built.
Rockwell lists 1771-IT as Discontinued, replacement category Engineering Replacement.
The published discontinued date is Not published.
The family replacement path is a 1756 or 1794 migration, which means the field wiring, the wiring arms and the addressing scheme all change. Buying the same catalog number is usually cheaper than re-terminating a panel.
Ask for a photo of the label side and the wiring arm. A module removed without its arm has to be re-keyed and re-wired, which is where most of the cost of a used card actually sits.
Check the module series letter against the chassis series: an A-series card in an A1B chassis works, but the reverse combination is what produces "module not recognised" faults.
These are static-sensitive cards. A unit shipped loose without conductive foam is a risk, whatever the price.
How many inputs does 1771-IT have?
8, on the published 1771 data sheet.
What input signal does 1771-IT accept?
DC, fast response.
Which 1771 chassis will accept 1771-IT?
Series A and B chassis.
Is 1771-IT still available from Rockwell?
No. It is listed as Discontinued with replacement category Engineering Replacement.
What is the discontinued date of 1771-IT?
Not published.
1771-IT is the fast response member of the 1771 PLC-5 DC input family, and the timing figure below is what separates it from the general purpose modules in the same technical data.
| Specification | Value |
|---|---|
| Catalog number | 1771-IT, fast response DC input module |
| Inputs per module | 8 |
| Input voltage range | 12 to 24V DC |
| Nominal input current | 8 mA at 12V DC, 24 mA at 24V DC |
| On-state and off-state voltage | On-state 10V DC minimum; off-state 4V DC maximum |
| Off-state current | 1.3 mA at 4V DC; the source table prints the unit as A while every other module in the same table is published in mA |
| Input impedance | 1 to 2 kOhm on-state, 2 to 3 kOhm off-state |
| Input signal delay | 0.6 ms plus or minus 0.2 ms, on or off, the fastest published delay in the 1771 DC input family |
| Power dissipation | 5.9 W maximum, 0.4 W minimum |
| Backplane current | 74 mA at 5V DC |
| Isolation voltage | 1500V AC rms |
| Operating temperature | 0 to 60 degrees C; storage minus 40 to 85 degrees C; 5 to 95 percent humidity without condensation |
| Keying | Between 6 and 8, and between 32 and 34 |
| Source | 1771-TD180-EN-P, 1771 digital I/O DC input and output modules, 1771-IT section |
Six tenths of a millisecond is the reason this module exists. The general purpose 1771 DC inputs publish fifteen milliseconds plus or minus seven, and a registration mark or a fast interlock cannot be handled at that speed, so the part number for the fast path is this one.
The on-state point at ten volts and the off-state point at four volts leave a five volt window in a twelve to twenty four volt system. That window is narrow on purpose: a fast module has less filtering, so it accepts less noise between the two thresholds than a slow module would.
Eight inputs with a keying pair at six to eight and thirty two to thirty four means this module cannot be swapped with a sixteen point input by accident. The keying is doing the protecting, and a wiring arm from another input module will not seat.
The measured delay is specified plus or minus two tenths of a millisecond in both directions. That symmetry matters for an edge that is timed from both the rising and the falling transition, which is exactly the case a fast input is bought for.
Every figure here is taken from 1771-TD180-EN-P for the 1771-IT section. Where the source table prints a unit that conflicts with the rest of the family, the row says so rather than silently correcting it.
The gap between the on-state and off-state windows is the noise margin of the whole channel. A module that is on above 79 volts and off below 43 volts tolerates a large amount of induced noise between those two thresholds, and a module with a narrow gap will chatter on a long unshielded run.
Series letters carry real differences. A Series C module is not a cosmetic update of Series A, and the publication that covers one series does not necessarily describe the other; a replacement decision on an installed base has to read the series letter on the label first.
The published delay figures include a tolerance for a reason. Fifteen milliseconds plus or minus seven is a range that spans more than the nominal value, and a sequence that assumes the nominal value will occasionally see a scan where the input has not yet arrived.
Keying is a mechanical interlock, and the published keying positions are the only accepted ones for that catalog number. A wiring arm keyed for a different module type will either refuse to seat or, worse, seat on a module whose field wiring assumes a different voltage.
The wiring arm is the serviceable part. Field wires land on the arm, the arm carries the keying, and replacing a module means moving the arm rather than rewiring the panel. That is the practical reason the arm part number appears in the specification table.
A PLC-5 input module is specified by four numbers that matter on site: the voltage window in which the input is guaranteed on, the voltage below which it is guaranteed off, the current the field device must sink or source, and the delay the module adds before the processor sees the change.
Isolation voltage on these modules is a type test figure, not a continuous working voltage. Fifteen hundred volts AC rms for a minute is a dielectric proof, and a panel that sees a continuous common mode voltage has to be designed for that voltage rather than for the test figure.
Two wire and three wire field devices present very different loads. A module quoted at a minimum on-state current of a few milliamps will not reliably pick up a dry contact that carries almost nothing, and a module quoted at a high nominal current will not be driven by a low power sensor without a relay.
Every 1771 module in this family publishes its backplane current, its power dissipation and a maximum adjacent slot dissipation. Those three figures are how a chassis is planned: the backplane supply has a budget, the chassis has a thermal limit, and a hot module next to another hot module is a derating decision made on paper.
A module that is not compatible with a particular adapter is a statement about backplane protocol, not about power. The 1771 local I/O adapter family supports a subset of the catalog, and a module outside that subset will not run behind that adapter regardless of the wiring.
These modules are mature products with an installed base measured in decades, which changes what the page is for. It is not a selection tool for new designs; it is a reference for identifying, replacing and re-rating a module that is already in a panel, often with the original drawing missing.
Filtering and delay are the same trade expressed twice. A module with a selectable delay lets the programmer choose between a fast response that inherits contact bounce and a slow response that ignores it, and the field device decides which of the two is correct.
Chassis temperature inside the enclosure is the sum of the modules, not the average. A rack full of input modules runs cool, a rack with high dissipation output modules runs hot, and the published maximum adjacent slot dissipation is the rule that keeps a hot module from cooking its neighbour.
Use it where the sequence needs the edge within a millisecond, keep the field wiring short and shielded because the filter is lighter, and do not substitute a general purpose input in its slot without re-timing the sequence.
The Allen-Bradley PLC-5 systems and 1771 I/O category groups the other catalog numbers, options and spare parts in the same range.