Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IF8 / 1756IF8

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $595.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1756-IF8 technical data PDF download 1756-IF8 ControlLogix 8 Point Analog Input Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IF8 (also written 1756IF8) is the workhorse analog input of the ControlLogix chassis: eight single-ended inputs, reconfigurable as four differential or two high-speed differential channels, backplane load 200 mA at 5.1 V DC and 30 mA at 24 V DC, power consumption 1.74 W (1756-TD002).

Resolution is quoted per count: 320 µV on the ±10 V range, 160 µV on 0...10 V, 80 µV on 0...5 V and 0.32 µA on 0...20 mA. Input impedance is 10 MΩ or greater in voltage mode and 249 Ω in current mode, which is what makes a 4...20 mA loop readable without an external resistor.

Accuracy is published separately for the two signal types: 0.05 % of range for voltage and 0.15 % for current, immediately after calibration, with module error over the temperature range quoted at 0.1 % and 0.3 % respectively. Module scan time runs from 16 to 488 ms depending on the notch filter setting.

Isolation is 250 V continuous basic from inputs to the backplane, with no isolation between individual inputs. That is the line that separates the IF8 from the IF8I, and it decides whether grounded thermocouples or transmitters on separate supplies may be mixed on one module. Technical data 1756-TD002, user manual 1756-UM009, installation instructions 1756-IN063.

1756-IF4FXOF2F
4 high-speed differential inputs + 2 outputs, 375 mA, reinforced isolation
In stock
1756-IF6CIS
6 isolated current inputs with sourcing 24 V DC loop supply
In stock
1756-IF6I
6 isolated inputs, 16-bit, 250 mA, channel-to-channel basic isolation
In stock
1756-IF8
8 single-ended / 4 differential inputs, 200 mA, 250 V basic to backplane
In stock
1756-IF8H
8 differential HART current inputs, A and B series
In stock
1756-IF16
16 single-ended / 8 differential inputs, 200 mA, 15 Hz bandwidth
In stock
1756-IF16H
16 differential HART current inputs, A and B series
In stock
1756-IRT8I
8 isolated RTD and thermocouple inputs, 24-bit, 1756-CJC required
In stock
1756-IR6I
6 isolated RTD inputs, 20-pin block, discontinued 2017
In stock
1756-IT6I
6 thermocouple inputs, two mV ranges, one CJC sensor
In stock
1756-IT6I2
6 isolated thermocouple inputs, 16-bit, two CJC sensors
In stock

 Application
 Analog input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IF8
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 8
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Analog Input Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN063 (analog I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IF8 analog input module product photograph 1756-IF8 terminal side product photograph 1756-IF8 label detail product photograph

Where the module sits in a typical system

The IF8 is the standard choice for a mixed analog panel: pressure and level transmitters on 4...20 mA, a few 0...10 V signals from drives, and temperature only where a thermocouple is already conditioned externally.

Because all eight channels share a reference, the IF8 suits a marshalled installation where every transmitter is loop-powered from the same panel supply and returns to the same common — the ordinary case in process skids and packaged plant.

Where the panel has to prove separation between field circuits, the module is the wrong starting point. Specify the IF8I and get 250 V reinforced to the backplane plus basic channel-to-channel, at 24-bit resolution.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's analogue I/O instructions include keying as a step, and a block keyed for a different module will not seat.
  2. Wire signal conductors to category 2 and keep them out of the same duct as the 480 V motor feeders. The analogue front end is the part of the rack that reads induced noise as measurement.
  3. Terminate the cable shield at the panel earth, not at the module terminals. A shield carried onto the RTB becomes an antenna for the next drive cabinet.
  4. Set the notch filter to the local mains frequency — 50 Hz or 60 Hz — in the Logix Designer project. The published settling time, scan time and noise rejection figures are all quoted at a selected notch frequency.
  5. Check the field range against the module's real range, not the sensor's nominal one. An IF6I accepts 0...21 mA with overrange indication, which is wider than a 4...20 mA transmitter needs and narrower than a 0...25 mA device supplies.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Basic isolation only  250 V basic to the backplane and no channel-to-channel barrier. Grounded junctions at different potentials need the IF8I.
 Check 3  Scan time follows the notch filter  16...488 ms across the filter settings. A 488 ms update is a deliberate choice for noise rejection, not a fault.
 Check 4  Current input is 249 Ω  A 4...20 mA loop across 249 Ω develops 1.0...5.0 V at the terminals; the loop supply has to carry that burden.
 Check 5  Backplane 200 mA  Cheaper than the isolated family per channel, but a chassis of eight IF8 modules still draws 1.6 A from the 5.1 V rail.

Specifications per Rockwell publication 1756-TD002 (ControlLogix I/O Modules Specifications); module behaviour per 1756-UM009 and 1756-IN050.

Replacing a 1756-IF6I of an earlier generation

The isolated equivalent is 1756-IF8I: eight isolated channels, 250 V reinforced to the backplane, 250 V basic input-to-input, 24-bit resolution.

For channel count without isolation, 1756-IF16 carries 16 single-ended inputs at the same 200 mA backplane figure and the same 250 V basic barrier.

For HART instruments, 1756-IF8H adds a HART modem (one per module on the A series, one per channel on the B series); for RTDs and thermocouples, 1756-IRT8I and 1756-IR12.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IF4FXOF2F — 4 high-speed differential inputs plus 2 high-speed outputs in one slot, 375 mA at 5.1 V DC, 250 V reinforced isolation.
  • 1756-IF8 — 8 single-ended (or 4 differential) inputs, 200 mA at 5.1 V DC, 250 V basic isolation to the backplane.
  • 1756-IF16 — 16 single-ended inputs, 200 mA at 5.1 V DC, same ranges as the IF8 with 15 Hz channel bandwidth.
  • 1756-IF6I — 6 individually isolated inputs, 250 mA at 5.1 V DC, 16-bit resolution, channel-to-channel isolation.
  • 1756-IF6CIS — 6 isolated current inputs with per-channel 24 V DC loop sourcing for 2-wire transmitters.
  • 1756-IF8H / 1756-IF16H — the HART variants, 8 or 16 differential current inputs, one modem per module (A series) or per channel (B series).
  • 1756-IRT8I / 1756-IR12 — RTD and thermocouple measurement, 250 V reinforced isolation, 24-bit resolution.
  • 1756-TBNH / 1756-TBCH / 1756-TBSH / 1756-TBS6H — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IF8 ControlLogix 8 Point Analog Input Module | Rockwell

What is the 1756-IF8?

An 8-channel analog input module for the ControlLogix chassis, configurable as 8 single-ended, 4 differential or 2 high-speed differential inputs.

What is the backplane current?

200 mA at 5.1 V DC and 30 mA at 24 V DC, 1.74 W power consumption (1756-TD002).

What resolution does it have?

320 µV per count on ±10 V, 160 µV on 0...10 V, 80 µV on 0...5 V and 0.32 µA per count on 0...20 mA.

What accuracy is published?

0.05 % of range for voltage and 0.15 % for current immediately after calibration; module error 0.1 % and 0.3 % over the temperature range.

What isolation does it provide?

250 V continuous basic insulation from inputs to the backplane, with no isolation between individual inputs.

How long is the scan time?

16...488 ms, depending on the notch filter configuration.

Can I mix voltage and current channels?

Yes — each channel is configured individually for its range in the Logix Designer project.

What documents cover it?

1756-TD002 for technical data, 1756-UM009 for the user manual and 1756-IN063 for installation.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IF8. Values re-checked 15 November 2026.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)