Product Details:
Payment & Shipping Terms:
|
The 1756-IF6CIS (also written 1756IF6CIS) is the sourcing current loop input of the ControlLogix range: six isolated current inputs that can supply the 24 V DC loop power for 2-wire transmitters themselves, one loop per channel, or accept an external user-supplied 24 V DC loop supply instead (1756-TD002).
That capability is the whole point of the catalogue number. A standard analog input measures a current that some other device has to generate; the IF6CIS terminates a 2-wire transmitter directly, sources its loop, and measures the return. The field wiring is two conductors per channel instead of a separate loop supply, a distributor and a measurement input.
Rockwell's published wiring covers both arrangements: transmitter on the module's own 24 V DC loop supply, or transmitter on an external supply with the module measuring the loop current. Where an external supply is used, the technical data states it must not exceed 150 VA.
Published values for this catalogue number are the six isolated channels, the sourcing 24 V DC loop arrangement, the 20-pin removable terminal block (1756-TBNH or 1756-TBSH), a T4A North American and T4 IEC temperature code, and open-style enclosure. Rockwell's current edition of 1756-TD002 no longer carries the consolidated backplane current and resolution table for this discontinued module, and we do not print figures here that we cannot cite — ask us for the module-specific table if the design depends on them. Technical data 1756-TD002, user manual 1756-UM009.
1756-IF4FXOF2F |
4 high-speed differential inputs + 2 outputs, 375 mA, reinforced isolation |
In stock |
1756-IF6CIS |
6 isolated current inputs with sourcing 24 V DC loop supply |
In stock |
1756-IF6I |
6 isolated inputs, 16-bit, 250 mA, channel-to-channel basic isolation |
In stock |
1756-IF8 |
8 single-ended / 4 differential inputs, 200 mA, 250 V basic to backplane |
In stock |
1756-IF8H |
8 differential HART current inputs, A and B series |
In stock |
1756-IF16 |
16 single-ended / 8 differential inputs, 200 mA, 15 Hz bandwidth |
In stock |
1756-IF16H |
16 differential HART current inputs, A and B series |
In stock |
1756-IRT8I |
8 isolated RTD and thermocouple inputs, 24-bit, 1756-CJC required |
In stock |
1756-IR6I |
6 isolated RTD inputs, 20-pin block, discontinued 2017 |
In stock |
1756-IT6I |
6 thermocouple inputs, two mV ranges, one CJC sensor |
In stock |
1756-IT6I2 |
6 isolated thermocouple inputs, 16-bit, two CJC sensors |
In stock |
Application |
Analog input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-IF6CIS |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
6 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Analog Input Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN063 (analog I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The IF6CIS suits a skid with six or fewer 2-wire transmitters and no existing loop supply: tank level, pressure and flow on a packaged unit, where the panel is built once and the field wiring has to be short.
It is also the module for a remote enclosure that has no 24 V distribution of its own, because the loop power comes from the rack rather than from a separate field supply.
For a plant with a marshalling panel and a central loop supply, the sourcing capability is redundant and the IF6I or IF8 gives the same measurement with published resolution and accuracy figures. Specify the IF6CIS when the loop power genuinely has to come from the module.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | External supply limit 150 VA | If the loop is powered externally, the technical data caps the supply at 150 VA. A larger shared supply is outside the published arrangement. |
| Check 3 | 2-wire transmitters only for sourcing | Loop power from the module suits 2-wire transmitters. A 4-wire transmitter has its own supply and the module measures its current instead. |
| Check 4 | Discontinued: plan the spares | The catalogue number is no longer in production. Replacement planning matters more than for an active module, and the wiring is not interchangeable with the IF6I. |
| Check 5 | Two conductors per channel | The savings in panel space are real, but the loop is now dependent on the module's own supply. A module fault removes the loop, not just the measurement. |
Specifications per Rockwell publication 1756-TD002 (ControlLogix I/O Modules Specifications); module behaviour per 1756-UM009 and 1756-IN050.
The measurement-only equivalent is 1756-IF6I: six isolated channels at 250 mA backplane, with 16-bit resolution and a published accuracy figure.
For 2-wire transmitters with an external loop supply, 1756-IF8 or 1756-IF16 measure 0...20 mA at 249 Ω input impedance.
For HART digital communication on the same loop, 1756-IF8H and 1756-IF16H add a HART modem over the current input.
What is the 1756-IF6CIS?
A 6-channel isolated current input module that sources 24 V DC loop power for 2-wire transmitters, or measures a loop powered by an external supply.
Does it power the transmitter?
Yes — each channel can supply the loop, which removes the need for a separate loop supply and distributor per transmitter.
Can I use an external loop supply instead?
Yes. Rockwell's published wiring shows both arrangements; the external supply must not exceed 150 VA.
What terminal block does it use?
A 20-pin removable terminal block, 1756-TBNH or 1756-TBSH, ordered separately.
What is its temperature code?
T4A in North America and T4 under IEC, with an open-style enclosure.
Is it still in production?
No. It is a discontinued catalogue number, so spares and replacement planning should be part of the design review.
What is the backplane current?
Rockwell's current 1756-TD002 does not publish the consolidated backplane figure for this module; ask us for the module-specific table if the chassis budget depends on it.
Which module replaces it for measurement only?
1756-IF6I — same six isolated channels, without the sourcing loop supply, with 16-bit resolution and a published accuracy figure.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IF6CIS. Values re-checked 15 November 2026.