22CD142A103 is an PowerFlex 400 drive for fan and pump duty: 480 V AC, three phase, 142 A output, 75 kW / 100 HP, frame E.
The 400 range covers 2.2 to 37 kW at 240 V and 2.2 to 250 kW at 480 V, and the drive is built around variable torque loads, so the ratings below are the fan and pump ones.
Quick answer. 22CD142A103 is a Rockwell Automation PowerFlex 70 drive, 400 V AC, normal duty (), frame E, .
| 22CD030F103 | 15 kW / 20 HP | IN STOCK |
| 22CD030H103 | 15 kW / 20 HP | IN STOCK |
| 22CD030N103 | 15 kW / 20 HP | IN STOCK |
| 22CD038A103 | 18.5 kW / 25 HP | IN STOCK |
| 22CD045A103 | 22 kW / 30 HP | IN STOCK |
| 22CD060A103 | 30 kW / 40 HP | IN STOCK |
| 22CD072A103 | 37 kW / 50 HP | IN STOCK |
| 22CD088A103 | 45 kW / 60 HP | IN STOCK |
| 22CD105A103 | 55 kW / 75 HP | IN STOCK |
| 22CD142A103 | 75 kW / 100 HP | IN STOCK |
| 22CD170A103 | 90 kW / 125 HP | IN STOCK |
| 22CD208A103 | 110 kW / 150 HP | IN STOCK |
| 22CD260A103 | 132 kW / 200 HP | IN STOCK |
| 22CD310A103 | 160 kW / 250 HP | IN STOCK |
| 22CD370A103 | 200 kW / 300 HP | IN STOCK |
| 22CD460A103 | 250 kW / 350 HP | IN STOCK |
| 22CD6P0F103 | 2.2 kW / 3.0 HP | IN STOCK |
| 22CD6P0N103 | 2.2 kW / 3.0 HP | IN STOCK |
Catalog number |
22CD142A103 |
Voltage rating (b) |
D - 480 V AC, three phase |
Output current rating (c) |
142 A |
Power rating |
75 kW / 100 HP |
Frame size |
E |
Enclosure (d A) |
Panel mount - IP30, NEMA/UL Type 1 |
Interface module (e 1) |
Fixed keypad |
Emission class (f 0) |
not filtered |
Version (g 3) |
RS485 |
Rating code |
142 - output current in amps |
Source |
22C-TD001 Catalog Number Explanation, tables c1 (240 V) and c2 (480 V) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 22C-TD001 (module specifications) and 22C-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
22C is the PowerFlex 400 family; position b is the voltage class, here 480 V AC, three phase.
Positions 6 to 8 are the output current code, 142, which reads as 142 A.
Position d is the enclosure, e the interface module (the field drive ships with the fixed keypad), f the emission class - 0 means not filtered - and g the version, 3 being RS485.
At 480 V AC, three phase the drive delivers 142 A continuous at 75 kW (100 HP) on variable torque fan and pump load.
Enclosure d=N is the panel mount IP20 open drive; frame C drives are only offered with IP20 open, and a field installed conversion kit is needed to reach the IP30 NEMA/UL Type 1 rating.
Built-in features for air handlers and pumps include PID, sleep/wake, pipe fill, damper control, purge and fire/freeze inputs, plus skip frequency bands that keep a fan out of a resonant speed.
Built-in features aimed at air handlers and pumps include the PID loop, sleep/wake control, pipe fill, a damper and purge routine, and the skip frequency bands that keep a fan out of a resonant speed.
d=F is the flange mount, offered on frame C only, for heat sink through panel mounting.
d=F is the flange mount, offered on frame C only, for heat sink through panel mounting.
Frame D and larger ratings normally ship as d=A, the IP30 NEMA/UL Type 1 enclosure, with an unfiltered drive (f=0) needing an external filter or a filtered enclosure to meet the site emission limits.
The frame (C, D, E or F) because it decides terminal wire range - frame C accepts 8 AWG, frame D 2 AWG, frame E and above 4/0 AWG or larger.
The enclosure letter against the installed environment, since an IP20 open drive inside a washdown area is the wrong build.
Whether the application is really variable torque; the 400 is a fan and pump drive, and a constant torque load should be sized on a different family.
Voltage classes, current codes, kW and HP values, frame sizes and enclosure letters are transcribed from 22C-TD001: Catalog Number Explanation and the 200-240 V and 380-480 V rating tables.
Feature statements - PID, sleep/wake, pipe fill, purge, skip frequencies, variable torque sizing - come from the product description and feature list in the same publication.
What is 22CD142A103?
PowerFlex 400 fan and pump drive, 480 V AC, three phase, 142 A, 75 kW / 100 HP, frame E.
What is the output current of 22CD142A103?
142 A at 480 V AC, three phase.
What power rating does 22CD142A103 have?
75 kW, 100 HP.
What frame size is 22CD142A103?
Frame E.
What enclosure does 22CD142A103 use?
Panel mount - IP30, NEMA/UL Type 1.
Related catalog numbers in the same rating code. Same A power stage, different option string - the enclosure, HIM, communication and safety positions are what change between them.
22CB012F103 (2.2 kW / 3.0 HP) · 22CB012H103 (2.2 kW / 3.0 HP) · 22CB012N103 (2.2 kW / 3.0 HP) · 22CB017F103 (3.7 kW / 5.0 HP) · 22CB017H103 (3.7 kW / 5.0 HP) · 22CB017N103 (3.7 kW / 5.0 HP) · 22CB024H103 (5.5 kW / 7.5 HP) · 22CB024N103 (5.5 kW / 7.5 HP) · 22CB033F103 (7.5 kW / 10 HP) · 22CB033H103 (7.5 kW / 10 HP)