The 1794-VHSC counts two quadrature axes at up to 1 MHz in x1 mode, with A, B and Z inputs per group, five digital filter settings and eight compare windows driving two outputs.
This is the position and registration card: encoder feedback for a registration mark, a high-speed gate, or a window comparator that has to act in microseconds rather than in a scan.
| 1794-IJ2 | 2-channel frequency input module, 1...32 kHz | IN STOCK |
| 1794-IJ2XT | 2-channel frequency input module, extended temperature | IN STOCK |
| 1794-VHSC | 2-axis very high speed counter, 1 MHz, 8 compare windows | IN STOCK |
| 1794-ID2 | 2-channel counter with A, B, Z and gate inputs | IN STOCK |
| 1794-IP4 | 4-channel counter module, 100 kHz | IN STOCK |
Application |
FLEX I/O very high speed counter, 1794 terminal base |
Cat Num |
1794-VHSC |
Brand Name |
Rockwell |
Channels |
2 groups, A/A, B/B and Z/Z inputs |
Frequency |
1 MHz at x1, 500 kHz at x2, 250 kHz at x4 |
Input levels |
5V inputs on above 2.6V, +/-6V maximum; 15...24V inputs on above 12.5V |
Filtering |
Off, 10 us, 100 us, 1 ms, 10 ms |
Compare windows |
8 |
Outputs |
5...7V or 10...31V, 0.5 or 1.0 A per output |
Output delay |
25 us turn-on, 150 us turn-off |
Leakage |
0.3 mA maximum |
External supply current |
100 mA at 24V DC |
Power dissipation |
5 W (17.1 BTU/hr) |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
2 groups of A/A, B/B and Z/Z inputs give two independent quadrature axes with index pulses.
1 MHz at x1, 500 kHz at x2 and 250 kHz at x4 is the published ceiling, so the resolution multiplier costs bandwidth.
Five filter settings — off, 10 us, 100 us, 1 ms and 10 ms — trade noise immunity against count rate, and the choice is per application, not per module.
8 compare windows produce outputs when the count passes a setpoint, so a registration correction can be made without the PLC scan in the path.
5V inputs switch on above 2.6V and tolerate +/-6V, and 15...24V inputs switch on above 12.5V — two distinct front-end classes.
Outputs are 5...7V or 10...31V, with 0.5 or 1.0 A per output, 0.9 or 4.0 A per pair, and a 0.5 or 1.0V drop.
Turn-on is 25 us and turn-off 150 us, which is fast enough to fire a marker solenoid from a compare window.
Leakage is 0.3 mA maximum, so a solid-state input downstream does not see a false on-state.
Short-circuit protection is provided, and after a short the module requires a power cycle to restore the output.
Figure 18 derates the output supply: 29V at 25 deg C falling to 24V at 55 deg C, which is the number to design the output supply against.
100 mA at 24V DC and 5 W (17.1 BTU/hr) is the module budget.
0...55 deg C operating range — no extended temperature version appears in the 1794 publication for this card.
Encoder cable is shielded, twisted pair per channel, with A, B and Z on separate pairs and the shield at the panel.
A 5V differential encoder and a 24V sensor do not share a group, because the front-end class is set per group.
Check the derated supply voltage at the maximum cabinet temperature, not at 25 deg C.
After a short circuit, plan the power cycle: the output stays off until the module is restarted.
Registration and cut-off control where a compare window has to act within microseconds.
Two-axis encoder feedback on a machine too fast for a counter instruction in the PLC.
Not for flow totalisation; 1...32 kHz and gate inputs are on the 1794-IJ2.
Not for low-speed contact counting; a digital input is enough.
What is the maximum count frequency?
1 MHz at x1, 500 kHz at x2 and 250 kHz at x4.
How many axes has the 1794-VHSC?
Two groups, each with A/A, B/B and Z/Z inputs.
What filtering is available?
Off, 10 us, 100 us, 1 ms and 10 ms.
How many compare windows does it provide?
Eight.
What are the output ratings?
5...7V or 10...31V, 0.5 or 1.0 A per output, with 25 us turn-on and 150 us turn-off.
How does the output supply derate?
29V at 25 deg C down to 24V at 55 deg C.
1794-VHSC is a FLEX I/O specialty module for the 1794 system, documented here from the Rockwell specialty module technical data so that the input thresholds, the counting limits, the output ratings and the terminal base requirement are stated for this catalog number.
| Specification | Value |
|---|---|
| Catalog number | 1794-VHSC, FLEX I/O 2 channel very high speed counter |
| Inputs | 2 inputs, with 2 groups of A, B and Z pairs including returns, terminated for 5V DC or 15 to 24V DC at the terminal base |
| Maximum count | 16,777,215, a 24 bit counter |
| Maximum input frequency | 1.0 MHz counter and encoder times one, 500 kHz encoder times two, 250 kHz encoder times four, all without filters |
| Input voltage | 5V DC or 15 to 24V DC, determined by terminal base terminations |
| Input current | 19.1 mA at 5V DC and 25.7 mA at 6V DC on the 5V terminations; 6.1 mA at 15V DC and 10.2 mA at 24V DC on the high level terminations |
| On-state and off-state input | On-state 2.6V DC minimum at 5V terminations, 12.5V DC minimum at 15 to 24V terminations; off-state 1.25V DC or 1.8V DC maximum respectively |
| Input current thresholds | 5 mA minimum on-state, 0.25 mA maximum off-state |
| Input filter selections | Off, 10 microseconds, 100 microseconds, 1.0 ms, 10.0 ms per A, B, Z group |
| Outputs | 2 isolated groups of 2, 0.5 A at 5V DC or 1.0 A at 12 to 24V DC maximum, tied to 8 compare windows |
| Output voltage range | 5 to 7V DC, or 10 to 31V DC |
| Output protection | Leakage 300 microamps maximum, on-state drop 0.9V DC, short circuit current 0.9 A at 5V or 4.0 A at 12 to 24V with the output latched off until power is cycled |
| Surge and delay | Surge 2 A for 50 ms repeatable every 2 s; off to on 25 microseconds, on to off 150 microseconds, load dependent |
| Terminal base | 1794-TB3G or 1794-TB3GS, keyswitch position 1 |
| Source | 1794-TD017-EN-E FLEX I/O specialty modules, and 1794-IN067 installation instructions |
One megahertz on the counter input and half of that in times two quadrature, falling again to a quarter in times four, is the frequency ladder this module publishes. The filters are the trade: each stage of filtering costs bandwidth, and the top figure is only available with the filters off.
The outputs are the other half of the module. Two isolated groups of two outputs tied to eight compare windows, with a short circuit behaviour that latches off until power is cycled, make this a small cam controller. The latch is worth a commissioning note, because a field short stops the output until the panel is opened.
These modules are judged on four figures: the maximum rate or count, the minimum pulse width or processing time, the input threshold with its sensing current, and the output rating with its protection behaviour. The table carries all four, and the notes explain where each of them limits the machine rather than the module.
Wire off detection is the diagnostic that saves a commissioning day. A small detect current through a shunt resistor proves the field circuit is closed before the machine runs, and losing that function by wiring without the shunt is a silent trade.
Sensing threshold and sensing level are two different engineering questions. One asks whether a 5 volt or a 24 volt signal crosses the threshold reliably, the other asks how much current the front end draws and whether a two wire sensor can supply it, and both appear in the same table for that reason.
Short circuit protection that latches off until power is cycled is a behaviour a maintenance team has to know. It protects the module, and it also means a field short stops the output until someone opens the panel, which is a commissioning note rather than a datasheet footnote.
A counter module counts edges, so mechanical contact bounce becomes counts. Debounce is either a filter setting or a hardware answer, and a panel that uses a dry contact on a fast counter without either will report counts that do not exist.
Filter selections are the answer to electrical noise, and they cost resolution. Off, ten microseconds, a hundred microseconds, a millisecond and ten milliseconds per channel group is a menu, and choosing a heavy filter to clean up a noisy encoder also caps the maximum frequency the channel can count.
Compare windows turn a counter into a cam controller. Eight windows tied to two physical outputs is a small motion controller built from a counter module, and the resolution of the windows is the resolution of the machine, not the resolution of the counter.
These modules draw only a few milliamps from the flexbus, and their field supplies are separate. A rail budget that charges them like discrete outputs will over provision the adapter, while a rail that forgets the field supply will find the module dead but the indicators healthy.
The maximum count value is a range statement, not a memory statement. A twenty four bit counter wraps at over sixteen million counts, and a machine that counts a fast pulse train for a week has to know exactly when that wrap happens and how the program handles it.
A frequency input module with gate channels measures direction as well as rate. The gate input establishes direction while the frequency input provides the pulse train, and that pairing is what allows a flow meter or an encoder to report signed rate rather than speed alone.
A specialty module in a FLEX rail exists because the adapter cannot time an event. A scan based discrete module takes a snapshot, and a counter or frequency module does its own arithmetic between scans, which is why these parts carry processing time and pulse width limits instead of turn on delays.
Pulse width is the real bandwidth limit. A minimum pulse of a few microseconds defines how fast an input can toggle regardless of the nominal frequency, and an encoder with a fine line count at high speed will violate that before it violates the frequency rating.
Accuracy and resolution are quoted separately for a reason. A resolution of a hundredth of a percent with an accuracy of a few tenths of a percent means the display can show digits that the measurement does not justify, and a control loop tuned to those digits will chase noise.
The terminal base is part of the specification on these modules. The counter and frequency parts are documented on the TB3G family with the keyswitch at position one, and a base that lacks the sensing terminations will not provide the low level inputs the module is specified against.
Match the filter setting to the real pulse rate rather than to the nominal one, respect the latched short circuit behaviour, and program the compare windows before the machine is run.
Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.