The 1794-TBN is the NEMA-style screw clamp base, rated to 264V AC/DC, with a cover over the I/O wiring and room for larger gauge conductors.
It is the base for a 250V circuit: the standard 1794-TB3 stops at 132V AC/156V DC, and the analog isolation ratings that depend on a TBN base are quoted against it.
| 1794-TB2 | 16-terminal cage clamp base, 2-wire, up to 132V AC | IN STOCK |
| 1794-TB3 | 16-terminal cage clamp base, 3-wire devices | IN STOCK |
| 1794-TB3S | 16-terminal spring clamp base, 3-wire devices | IN STOCK |
| 1794-TB32 | 32-terminal cage clamp base for 32-point modules | IN STOCK |
| 1794-TB32S | 32-terminal spring clamp base for 32-point modules | IN STOCK |
| 1794-TB3T | temperature base with two cold junction compensation sets | IN STOCK |
| 1794-TB3TS | spring clamp temperature base with CJC sets | IN STOCK |
| 1794-TB3G | grounded screw clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TB3GS | grounded spring clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TBKD | cage clamp base with 16 knife disconnects | IN STOCK |
| 1794-TBN | NEMA-style screw clamp base, up to 264V AC/DC | IN STOCK |
| 1794-TBNF | fused NEMA-style base, eight 5 x 20 mm fuses | IN STOCK |
| 1794-TB37DS | 37-pin D-shell termination for digital and analog modules | IN STOCK |
| 1794-TB62DS | 62-pin D-shell termination for digital and analog modules | IN STOCK |
Application |
FLEX I/O NEMA-style terminal base, 1794 backplane |
Cat Num |
1794-TBN |
Brand Name |
Rockwell |
Termination |
Screw clamp, NEMA style, 16 I/O, 2 common, 2 +V, with wiring cover |
Voltage |
Up to 264V AC / DC |
Wire size |
Larger gauge conductors than the standard base |
Dimensions |
94 x 94 x 69 mm |
Operating temperature |
-20...70 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Up to 264V AC/DC on the terminals, which is what allows a 250V field circuit on a FLEX I/O module.
NEMA-style screw clamp with a cover over the I/O wiring, so the field terminals are protected and the installation looks like a NEMA assembly rather than an open terminal strip.
16 I/O, 2 common and 2 +V terminals — fewer power terminals than the digital base, and larger gauge wire accepted.
94 x 94 x 69 mm, the same footprint as the other bases, with -20...70 deg C operating range.
The 1794-OF4I and 1794-OF4IXT publish 250V continuous channel-to-channel isolation only with a TBN base; with TB2, TB3, TB3S, TB3T or TB3TS bases the figure is 120V.
The 1794-IF2XOF2I and 1794-IF2XOF2IXT follow the same rule: 250V with TBN, 120V with the TB3 family.
1500V AC for 60 s and 2550V DC for 1 s are the type tests quoted alongside that base-dependent rating.
The base does not create isolation; it supports the module's rating, so the module and base are specified together.
250V field circuits on isolated analog or AC modules.
Panels specified to NEMA practice, with the wiring cover and larger terminals.
Not a fuse holder; the 1794-TBNF carries eight 5 x 20 mm fuses for AC output modules.
Not for 32-point cards; the 1794-TB32 provides the terminal count.
35 x 7.5 mm DIN rail with 25 mm air space, or the 1794-NM1 panel-mount kit.
Zinc-plated, yellow-chromated steel rail for chassis grounding through the rail.
1492-EA35 rail locks in high-vibration installations.
One end cap per system, and bases plug together to form the backplane.
250V isolated analog loops, where the module's isolation rating needs this base.
NEMA-style panels with covered field wiring.
Not for 16-point digital I/O at 24V; the 1794-TB3 is cheaper and has more power terminals.
Not for fusing; the 1794-TBNF provides eight fused terminals.
What voltage is the 1794-TBN rated for?
Up to 264V AC/DC, against 132V AC/156V DC on the standard 1794-TB3.
Why does the base matter to isolation?
The 1794-OF4I and 1794-IF2XOF2I publish 250V continuous isolation only with a TBN base; other bases give 120V.
How many terminals has it?
16 I/O, 2 common and 2 +V, in a NEMA-style screw clamp with a wiring cover.
Does it hold fuses?
No; the 1794-TBNF is the fused version with eight 5 x 20 mm fuses.
What is the operating temperature?
-20...70 deg C.
What wire can it take?
Larger gauge conductors than the standard base, which is one reason it is chosen for 250V circuits.
1794-TBN is a FLEX I/O terminal base unit, not an I/O module. It is the part that carries the field terminals, plugs into the adjacent base to form the backplane, and holds the module on top. The termination type here is Screw clamp, NEMA style with 16 I/O, 2 common, 2 +V.
| Attribute | Value |
| Catalog number | 1794-TBN |
| Termination type | Screw clamp, NEMA style |
| Connections | 16 I/O, 2 common, 2 +V |
| Current capacity, maximum | module dependent |
| Wiring category | module dependent |
| Field voltage | 264V AC / DC |
| Operating temperature | -20...+70 C |
| Purpose in the range | A NEMA style screw clamp base for larger gauge wires, supplied with a cover for the I/O wiring. |
The conductor range for this base is 0.34 to 3.3 mm2 (22 to 12 AWG) solid or stranded copper rated 75 C or greater, with 1.2 mm maximum insulation, with a maximum current capacity of module dependent across the base. Those figures are the base rating and not the module rating: a 16 point module on a 10 A base is still limited by the module output current per channel.
Selecting a base is a compatibility step, not a preference step. The module data sheet names the bases that are permitted for it, and a base outside that list may key differently, may not carry the required common and voltage terminals, or may not be rated for the field voltage of the module.
FLEX I/O is a backplane-free architecture: the terminal base unit snaps onto the DIN rail to the right of the adapter and the bases plug together to form the backplane. The module then sits on top of the base, so the base is chosen for the field wiring and the module for the signal, and the two are ordered separately.
FLEX I/O bases and modules are separate line items on a purchase order, and the price of getting that wrong is a second shipment: a module without its base cannot be installed, and a base of the wrong termination type cannot be reworked in the field because the module keys to the base family.
For a retrofit into an existing slice, the addressing is decided by position rather than by catalog number: FLEX I/O assigns the module its place in the rack by the order of the bases on the rail, so inserting a module in the middle shifts the addresses of everything to its right and requires the program to be re-checked.
Mounting is a DIN rail operation on both parts and the order of assembly is base first, module second: the base slides onto the rail, its backplane fingers engage the neighbouring base, and the module is then pressed onto the base and secured. Removing a module does not break the backplane, which is why a failed slice can be swapped without rewiring the row.
The 22 to 12 AWG acceptance range on the standard bases is wider than the field device terminals in most panels, so the practical constraint is usually the device end, not the base end. Where a 24V DC sensor cable is 18 AWG and the base accepts 12 AWG, the conductor still has to be torqued to the published value rather than to feel.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
This part sits in the Allen-Bradley Flex I/O 1794 modules category, with the other models and spare parts listed alongside it.