Product Details:
Payment & Shipping Terms:
|
The 1794-TBKD is the maintenance base: 16 I/O, 18 common and 2 +V terminals, with a knife disconnect on each of the 16 I/O points.
A knife disconnect opens a field circuit without removing a wire or pulling the module, which is what a commissioning or troubleshooting step needs on a live panel.
| 1794-TB2 | 16-terminal cage clamp base, 2-wire, up to 132V AC | IN STOCK |
| 1794-TB3 | 16-terminal cage clamp base, 3-wire devices | IN STOCK |
| 1794-TB3S | 16-terminal spring clamp base, 3-wire devices | IN STOCK |
| 1794-TB32 | 32-terminal cage clamp base for 32-point modules | IN STOCK |
| 1794-TB32S | 32-terminal spring clamp base for 32-point modules | IN STOCK |
| 1794-TB3T | temperature base with two cold junction compensation sets | IN STOCK |
| 1794-TB3TS | spring clamp temperature base with CJC sets | IN STOCK |
| 1794-TB3G | grounded screw clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TB3GS | grounded spring clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TBKD | cage clamp base with 16 knife disconnects | IN STOCK |
| 1794-TBN | NEMA-style screw clamp base, up to 264V AC/DC | IN STOCK |
| 1794-TBNF | fused NEMA-style base, eight 5 x 20 mm fuses | IN STOCK |
| 1794-TB37DS | 37-pin D-shell termination for digital and analog modules | IN STOCK |
| 1794-TB62DS | 62-pin D-shell termination for digital and analog modules | IN STOCK |
Application |
FLEX I/O terminal base with knife disconnects |
Cat Num |
1794-TBKD |
Brand Name |
Rockwell |
Termination |
Cage clamp with 16 knife disconnects |
Connections |
16 I/O, 18 common, 2 +V |
Dimensions |
94 x 94 x 69 mm |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
16 knife disconnects, one per I/O terminal, opened and closed individually with a screwdriver.
16 I/O, 18 common and 2 +V terminals — the 2 +V arrangement is the 2-wire pattern, not the 18 +V of the 1794-TB3.
Cage clamp termination for the field wires, 94 x 94 x 69 mm footprint.
0...55 deg C operating range, narrower than the TB3 family, so this base is for a heated cabinet.
Loop isolation for troubleshooting: a channel can be opened while the rest of the card runs.
No wire removal, so a terminal cannot be landed on the wrong point during a check.
Commissioning sequence: energise the card, close one disconnect at a time, verify the field device.
The module stays powered; the disconnect acts on the field circuit, not on the backplane.
Discontinued catalog: the selection guide notes that discontinued catalogs may not have updated specifications, and to check the individual installation instructions.
2 +V terminals will not supply a group of 3-wire sensors.
0...55 deg C rules it out of an uncoated -XT island.
Not a fused base; the 1794-TBNF carries eight fuses for output modules.
35 x 7.5 mm DIN rail , or panel mount with the 1794-NM1 kit.
Zinc-plated, yellow-chromated steel rail for chassis grounding.
1492-EA35 rail locks in high-vibration locations.
Bases plug together, with one end cap per system.
Commissioning and maintenance panels where per-point isolation saves time.
Training or test rigs that need channels opened individually.
Not for production density; a standard base costs less and needs no disconnect.
Not for 250V circuits; the 1794-TBN is the high-voltage base.
What is a knife disconnect base?
A terminal base with a screwdriver-operated disconnect on each of its 16 I/O points.
How many disconnects has the 1794-TBKD?
16, one per I/O terminal.
How many terminals does it have?
16 I/O, 18 common and 2 +V.
What is the operating temperature?
0...55 deg C.
Does it disconnect the module from the backplane?
No; it opens the field circuit only.
Is it a current catalog number?
The selection guide lists it as discontinued and advises checking the installation instructions.
1794-TBKD is a FLEX I/O terminal base unit, not an I/O module. It is the part that carries the field terminals, plugs into the adjacent base to form the backplane, and holds the module on top. The termination type here is Cage clamp, knife disconnect with 16 I/O, 18 common, 2 +V.
| Attribute | Value |
| Catalog number | 1794-TBKD |
| Termination type | Cage clamp, knife disconnect |
| Connections | 16 I/O, 18 common, 2 +V |
| Current capacity, maximum | module dependent |
| Wiring category | module dependent |
| Field voltage | Per module |
| Operating temperature | 0...+55 C |
| Purpose in the range | A cage clamp base with 16 knife disconnects so a field circuit can be opened without removing a conductor. |
The conductor range for this base is 0.34 to 3.3 mm2 (22 to 12 AWG) solid or stranded copper rated 75 C or greater, with 1.2 mm maximum insulation, with a maximum current capacity of module dependent across the base. Those figures are the base rating and not the module rating: a 16 point module on a 10 A base is still limited by the module output current per channel.
Selecting a base is a compatibility step, not a preference step. The module data sheet names the bases that are permitted for it, and a base outside that list may key differently, may not carry the required common and voltage terminals, or may not be rated for the field voltage of the module.
FLEX I/O is a backplane-free architecture: the terminal base unit snaps onto the DIN rail to the right of the adapter and the bases plug together to form the backplane. The module then sits on top of the base, so the base is chosen for the field wiring and the module for the signal, and the two are ordered separately.
FLEX I/O bases and modules are separate line items on a purchase order, and the price of getting that wrong is a second shipment: a module without its base cannot be installed, and a base of the wrong termination type cannot be reworked in the field because the module keys to the base family.
For a retrofit into an existing slice, the addressing is decided by position rather than by catalog number: FLEX I/O assigns the module its place in the rack by the order of the bases on the rail, so inserting a module in the middle shifts the addresses of everything to its right and requires the program to be re-checked.
Mounting is a DIN rail operation on both parts and the order of assembly is base first, module second: the base slides onto the rail, its backplane fingers engage the neighbouring base, and the module is then pressed onto the base and secured. Removing a module does not break the backplane, which is why a failed slice can be swapped without rewiring the row.
The 22 to 12 AWG acceptance range on the standard bases is wider than the field device terminals in most panels, so the practical constraint is usually the device end, not the base end. Where a 24V DC sensor cable is 18 AWG and the base accepts 12 AWG, the conductor still has to be torqued to the published value rather than to feel.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.