Product Details:
Payment & Shipping Terms:
|
The 1794-TB37DS replaces screw terminals with a 37-pin D-shell connector, so an entire module's field wiring arrives as one pre-made cable.
Used with both digital and analog modules, it is the base for a panel built as a wiring harness rather than point-to-point.
| 1794-TB2 | 16-terminal cage clamp base, 2-wire, up to 132V AC | IN STOCK |
| 1794-TB3 | 16-terminal cage clamp base, 3-wire devices | IN STOCK |
| 1794-TB3S | 16-terminal spring clamp base, 3-wire devices | IN STOCK |
| 1794-TB32 | 32-terminal cage clamp base for 32-point modules | IN STOCK |
| 1794-TB32S | 32-terminal spring clamp base for 32-point modules | IN STOCK |
| 1794-TB3T | temperature base with two cold junction compensation sets | IN STOCK |
| 1794-TB3TS | spring clamp temperature base with CJC sets | IN STOCK |
| 1794-TB3G | grounded screw clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TB3GS | grounded spring clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TBKD | cage clamp base with 16 knife disconnects | IN STOCK |
| 1794-TBN | NEMA-style screw clamp base, up to 264V AC/DC | IN STOCK |
| 1794-TBNF | fused NEMA-style base, eight 5 x 20 mm fuses | IN STOCK |
| 1794-TB37DS | 37-pin D-shell termination for digital and analog modules | IN STOCK |
| 1794-TB62DS | 62-pin D-shell termination for digital and analog modules | IN STOCK |
Application |
FLEX I/O D-shell termination base, digital and analog |
Cat Num |
1794-TB37DS |
Brand Name |
Rockwell |
Termination |
37-pin D-shell connector |
Used with |
Digital and analog modules |
Dimensions |
94 x 94 x 69 mm; 127 x 94 x 69 mm with an extended module |
Operating temperature |
0...55 deg C |
Same-family catalog numbers: 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB32. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1794 family.
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
37-pin D-shell, mating with a pre-wired cable assembly instead of individual terminals.
Digital and analog modules both use it, which lets one cable style serve the whole island.
94 x 94 x 69 mm, or 127 x 94 x 69 mm with an extended module installed.
0...55 deg C operating range — narrower than the screw terminal bases.
One connector replaces dozens of terminations, so commissioning time drops to plugging in.
Wiring is built and tested off-panel, which is the usual reason for choosing a D-shell base.
Replacement is a cable swap, but a fault then follows the whole cable rather than one point.
Field diagnostics need a breakout, since individual points are not exposed at the base.
Machine builders who wire harnesses in-house and ship them with the panel.
Analog and digital islands in the same cabinet, using the same 37-pin connector.
Not for high-voltage circuits; the D-shell pattern is for module-level signals.
Not the 62-pin variant; the 1794-TB62DS carries the higher pin count.
35 x 7.5 mm DIN rail with 25 mm air space around the system.
Zinc-plated, yellow-chromated steel rail for chassis grounding.
1794-NM1 panel kit where the base is not on rail.
One end cap per system; bases plug together for the backplane.
Harness-wired panels with pre-tested cable assemblies.
Skids and machines where field wiring is made in a workshop.
Not for ad-hoc field termination; a breakout or the screw bases are simpler there.
Not for the 62-pin modules; use the 1794-TB62DS.
What connector does the 1794-TB37DS use?
A 37-pin D-shell connector for the field wiring.
Which modules can use it?
Digital and analog FLEX I/O modules.
What are its dimensions?
94 x 94 x 69 mm, or 127 x 94 x 69 mm with an extended module fitted.
What is the operating temperature?
0...55 deg C.
How does it differ from the 1794-TB62DS?
Pin count: 37 against 62.
Does it support per-point troubleshooting?
Not directly; the points are combined in one connector.
1794-TB37DS is a FLEX I/O terminal base unit, not an I/O module. It is the part that carries the field terminals, plugs into the adjacent base to form the backplane, and holds the module on top. The termination type here is D-shell, 37 pin with per module pinout.
| Attribute | Value |
| Catalog number | 1794-TB37DS |
| Termination type | D-shell, 37 pin |
| Connections | per module pinout |
| Current capacity, maximum | 10 A |
| Wiring category | 2 |
| Field voltage | Per module |
| Operating temperature | -20...+70 C |
| Purpose in the range | A 37 pin D-shell base measuring 127 by 94 by 69 mm with an expansion module installed, used for pre-wired cable interfaces. |
The conductor range for this base is 0.34 to 3.3 mm2 (22 to 12 AWG) solid or stranded copper rated 75 C or greater, with 1.2 mm maximum insulation, with a maximum current capacity of 10 A across the base. Those figures are the base rating and not the module rating: a 16 point module on a 10 A base is still limited by the module output current per channel.
Selecting a base is a compatibility step, not a preference step. The module data sheet names the bases that are permitted for it, and a base outside that list may key differently, may not carry the required common and voltage terminals, or may not be rated for the field voltage of the module.
FLEX I/O is a backplane-free architecture: the terminal base unit snaps onto the DIN rail to the right of the adapter and the bases plug together to form the backplane. The module then sits on top of the base, so the base is chosen for the field wiring and the module for the signal, and the two are ordered separately.
Temperature class is written per module and per base, and the lower of the two governs the slice. A 70 C base carrying a 55 C module is a 55 C slice, which is why the extended temperature modules exist as a matched set rather than as an upgrade to one part of the pair.
One point about the 24V DC digital slices that catches panel builders: the adapter supplies the field power for the modules on its own 24V output, and that output is current limited. On a 1794-ADN the supply output is 450 mA at 24V, so a slice of 16 point DC modules can exhaust the adapter before the cabinet is half filled, and a separate field supply has to be introduced rather than assumed.
Mounting is a DIN rail operation on both parts and the order of assembly is base first, module second: the base slides onto the rail, its backplane fingers engage the neighbouring base, and the module is then pressed onto the base and secured. Removing a module does not break the backplane, which is why a failed slice can be swapped without rewiring the row.
The 22 to 12 AWG acceptance range on the standard bases is wider than the field device terminals in most panels, so the practical constraint is usually the device end, not the base end. Where a 24V DC sensor cable is 18 AWG and the base accepts 12 AWG, the conductor still has to be torqued to the published value rather than to feel.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
Related models, options and spare parts for this range are listed in the Allen-Bradley Flex I/O 1794 modules category.