Allen Bradley PLC 1794-IG16 / 1794IG16

China Allen Bradley PLC 1794-IG16 / 1794IG16 supplier
Allen Bradley PLC 1794-IG16 / 1794IG16 supplier Allen Bradley PLC 1794-IG16 / 1794IG16 supplier Allen Bradley PLC 1794-IG16 / 1794IG16 supplier Allen Bradley PLC 1794-IG16 / 1794IG16 supplier Allen Bradley PLC 1794-IG16 / 1794IG16 supplier

Large Image :  Allen Bradley PLC 1794-IG16 / 1794IG16

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-IG16 / 1794IG16

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $148.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-IG16 technical data PDF download FLEX I/O 1794-IG16 / 1794IG16 16-Point 5V DC TTL Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-IG16 brings 16 TTL-level inputs into a FLEX I/O island, for boards and instruments that signal at 0...5V rather than 24V.

Its logic is inverted: 0...0.8V DC reads as logic low and is reported as On, while 2.0...5.5V DC reads as logic high and reports Off.

1794-IB8 8-point 24V DC sinking input module IN STOCK
1794-IB16 16-point 24V DC sinking input module IN STOCK
1794-IB32 32-point 24V DC sinking input module IN STOCK
1794-IB10XOB6 10 inputs / 6 sourcing outputs, 24V DC combo module IN STOCK
1794-IB16XOB16P 16 inputs / 16 protected sourcing outputs combo module IN STOCK
1794-IB16D 16-point diagnostic sinking input module IN STOCK
1794-IB16XT 16-point 24V DC sinking input, extended temperature IN STOCK
1794-IB10XOB6XT 10 inputs / 6 sourcing outputs, extended temperature IN STOCK
1794-IA8 8-point 120V AC input module IN STOCK
1794-IA16 16-point 120V AC input module IN STOCK
1794-IC16 16-point 48V DC sinking input module IN STOCK
1794-IG16 16-point 5V DC TTL input module IN STOCK
1794-IH16 16-point 125V DC sinking input module IN STOCK
1794-IM8 8-point 240V AC input module IN STOCK
1794-IM16 16-point 240V AC input module IN STOCK
1794-IV16 16-point 24V DC sourcing input module IN STOCK
1794-IV32 32-point 24V DC sourcing input module IN STOCK

Product Specifications 1794-IG16 (PDF)
 Application
 FLEX I/O TTL digital input
 Cat Num
 1794-IG16
 Brand Name
 Rockwell
 Number of inputs
 16, TTL
 On-state voltage
 0.2V DC min, 0V DC nom, 0.8V DC max
 Off-state voltage, max
 2...5.5V DC
 Off-state current, max
 4.1 mA
 Input impedance
 1.4 k ohm min, 1.5 k ohm typical
 Isolation
 50V continuous, Basic Insulation Type
 Flexbus current
 40 mA at 5V DC
 Power dissipation
 1.4 W at 5.5V DC
 Terminal base
 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-IG16 original product photograph, wide view 1794-IG16 original product photograph, wide view 1794-IG16 original product photograph, wide view

Logic polarity

Inverted TTL: -0.2...0.8V DC = logic low = 1 = On; 2.0...5.5V DC = logic high = 0 = Off.

A NOT instruction in the ladder program converts it to conventional true-equals-high logic, which the publication states explicitly.

On-state thresholds 0.2V min and 0.8V max, off-state above 2.0V DC, off current 4.1 mA maximum.

1.4 k ohm minimum input impedance, so the driving board has to source real current.

Wiring

Inputs on A-0...A-15, with the 5V supply on C-34...C-51 and commons on B-16...B-33.

0.01 uF capacitors rated 2000V minimum are shown across the input wiring in the publication's wiring drawing.

I/O cable must be shorter than 10 m (32.8 ft), a TTL limit rather than a FLEX I/O one.

Belden 8761 or equivalent shielded wire is the publication's recommendation.

Application

Interfacing TTL boards, encoders and lab instruments into a control island.

Bench and test rigs where 24V would damage the source.

Not for 24V field devices; the 1794-IB16 is the 24V sinking input.

Not for long cable runs; 10 m is the stated limit.

Electrical

50V continuous isolation, Basic Insulation Type, field side to system.

40 mA from the Flexbus at 5V, 1.4 W dissipation, which is light relative to 24V cards.

16 yellow status indicators driven from the field-side device.

The 5V rail is external, at 4.5...5.5V DC including 5 percent ripple.

Where it fits

TTL instrumentation islands.

Mixed panels where a few TTL signals sit beside 24V I/O.

Not for extended temperature; check the XT family instead.

Not for AC or 125V DC signals.

FAQ — 1794-IG16

How many inputs has the 1794-IG16?

16 TTL inputs.

Is the logic inverted?

Yes; 0...0.8V DC is logic low and reported as On.

What is the maximum cable length?

Less than 10 m (32.8 ft).

What is the off-state voltage?

2.0...5.5V DC, with 4.1 mA maximum off-state current.

What is the input impedance?

1.4 k ohm minimum, 1.5 k ohm typical.

Which terminal bases are used?

1794-TB3, 1794-TB3S, 1794-TB3K and 1794-TB3SK.


Data sources. Technical values on this page come from Rockwell publication 1794-IN119 (FLEX I/O 5V DC TTL Digital Input and Output Modules). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

Where the 1794-IG16 sits in the FLEX I/O range

1794-IG16 is a digital DC input with 16 inputs in the FLEX I/O range, rated for TTL, sinking. It mounts on the 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK terminal base unit, which is ordered separately and is the part that actually carries the field terminals.

AttributeValue
Catalog number1794-IG16
Module typedigital DC input
Points16 inputs
Electrical rangeTTL, sinking
Terminal base unit1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK
On-state input30V DC maximum, TTL thresholds
Power dissipation1.4 W at 5.5V DC
Operating temperature-20 to +55 C

Conformal coated variants carry a K suffix and exist because the same base can be asked to survive washdown, condensate, or corrosive atmosphere. Ordering the uncoated base and treating it in the field is not equivalent and does not carry the same published rating.

Temperature class is written per module and per base, and the lower of the two governs the slice. A 70 C base carrying a 55 C module is a 55 C slice, which is why the extended temperature modules exist as a matched set rather than as an upgrade to one part of the pair.

One point about the 24V DC digital slices that catches panel builders: the adapter supplies the field power for the modules on its own 24V output, and that output is current limited. On a 1794-ADN the supply output is 450 mA at 24V, so a slice of 16 point DC modules can exhaust the adapter before the cabinet is half filled, and a separate field supply has to be introduced rather than assumed.

On the 32 point bases the common and voltage terminals are grouped in eight pairs rather than eighteen, which is why the 32 point digital modules can mix sinking and sourcing groups in one slice and why the terminal numbering on the drawing does not follow the 16 point pattern.

Any FLEX I/O position is a pair on the purchase order: one base, one module. Stocking modules without bases, or bases without the matching modules, produces a slice that cannot be commissioned, and the two part numbers are never interchangeable across the 8, 16 and 32 point families.

Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.

Other catalog numbers and accessories for the same range are collected in the Allen-Bradley Flex I/O 1794 modules category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)