Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-IE8H / 1794IE8H

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $608.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 12 PCS
Detailed Product Description

1794-IE8H technical data PDF download FLEX I/O 1794-IE8H / 1794IE8H HART Analog 8 Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-IE8H is the HART-enabled eight-channel analog input card: 16-bit resolution, 0...20 mA or 4...20 mA, wire-off detection on every channel, and one HART field device per channel.

The HART modem is the whole point: the same pair of wires that carries the 4...20 mA loop carries the configuration and diagnostics of the transmitter, so a smart transmitter can be commissioned without a separate handheld.

1794-IE8 8-channel analog input module IN STOCK
1794-IE8XT 8-channel analog input module, extended temperature IN STOCK
1794-IE8H 8-channel HART analog input module IN STOCK
1794-IE12 12-channel analog input module IN STOCK
1794-IE12K 12-channel analog input module, conformal coated IN STOCK
1794-IF4I 4-channel isolated analog input module IN STOCK
1794-IF4IXT 4-channel isolated analog input, extended temperature IN STOCK
1794-IF4ICFXT 4-channel isolated analog input, conformal coated IN STOCK
1794-IF8IH 8-channel HART isolated analog input module IN STOCK
1794-IR8 8-channel RTD input module IN STOCK
1794-IRT8 8-channel thermocouple/RTD input module IN STOCK
1794-IRT8XT 8-channel thermocouple/RTD input, extended temperature IN STOCK
1794-IT8 8-channel thermocouple/mV input module IN STOCK
1794-IE8XOE4 8-input, 4-output analog combination module IN STOCK
1794-IE4XOE2 4-input, 2-output analog combination module IN STOCK
1794-IF2XOF2I 2-input, 2-output isolated analog combination module IN STOCK
1794-OE4 4-channel analog output module IN STOCK
1794-OE12 12-channel analog output module IN STOCK

Product Specifications 1794-IE8H (PDF)
 Application
 FLEX I/O HART analog input, 1794 terminal base
 Cat Num
 1794-IE8H
 Brand Name
 Rockwell
 Channels
 8, HART enabled, one field device per channel
 Input range
 0...20 mA, 4...20 mA
 Resolution
 16 bits
 Conversion rate
 10 ms at 50 Hz, 8.33 ms at 60 Hz
 Step response
 80 ms to 99% of full scale
 Accuracy
 0.1% of full scale at 20 deg C
 Isolation
 50V continuous, basic insulation; no channel isolation
 External supply current
 190 mA at 24V DC
 Power dissipation
 3.9 W (13.5 BTU/hr)
 Network
 ControlNet or EtherNet/IP adapter only
 Operating temperature
 -20...55 deg C

Same-family catalog numbers: 1794-IE8, 1794-IE8XT, 1794-IE12, 1794-IE12K. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1794 family.

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-IE8H original product photograph, wide view 1794-IE8H original product photograph, wide view 1794-IE8H original product photograph, wide view

HART and the loop

One HART field device per channel is the published limit; sharing a single device across two channels is not supported.

ControlNet or EtherNet/IP adapter only — the HART data path needs an adapter that carries it, and a Remote I/O adapter does not.

16-bit resolution on a 0...20 mA loop gives roughly 0.3 uA per count, far finer than the 12-bit general-purpose card.

Wire-off detection per channel reports a disconnected transmitter to the controller instead of a plausible zero reading.

Timing

Conversion rate is 10 ms at 50 Hz and 8.33 ms at 60 Hz, tied to the line frequency because the converter integrates over a mains cycle.

Step response to 99% of full scale is 80 ms — slower than the 12-bit card's 18.2 ms to 63%, and the difference matters in a fast control loop.

HART communication does not stop the analog update; the digital signal is superimposed on the loop current and the card decodes it in parallel.

The pairing of 50/60 Hz selection with the line frequency is a commissioning setting, not an automatic one on every adapter.

Supply and heat

190 mA at 24V DC is the module consumption, noticeably more than the 60 mA of the non-HART eight-channel card.

3.9 W (13.5 BTU/hr) is the dissipation to add to the enclosure calculation, and it is higher for the same channel count because of the HART circuitry.

The card does not supply loop power for the transmitter; a HART transmitter still needs its 24V loop supply in the panel.

-20...55 deg C operating range with the 75 mm depth of the HART module, against 53 mm for the standard analog cards.

Wiring practice

A 4...20 mA transmitter on channel 1 lands on the current terminals with the loop supply in series; the HART signal rides on the same pair.

The module is single-ended, so the loop return is the module common and a grounded transmitter can create a ground loop the card cannot break.

Shielded twisted pair for the loop is the normal practice; HART signalling is low-level and shares the cable with the 4...20 mA step changes.

Configuration changes are possible in RUN mode, which is how a range change on a live transmitter is made without stopping the process.

Where it fits

Smart transmitter installations where the HART diagnostics are wanted in the control system rather than on a handheld.

Panels with many loops and few spare parts — one card covers eight transmitters and reports which one is disconnected.

Not for fast loops. An 80 ms step response excludes fast pressure or flow control; the 1794-IF4I is the faster isolated alternative.

Not for thermocouples. HART is a 4...20 mA protocol; temperature inputs need the 1794-IRT8 or 1794-IT8.

FAQ — 1794-IE8H

How many HART channels has the 1794-IE8H?

Eight, with one HART field device per channel.

Which networks support it?

ControlNet or EtherNet/IP adapters; the HART data path is not carried by a Remote I/O adapter.

What is the resolution?

16 bits on a 0...20 mA or 4...20 mA input.

How fast is the update?

10 ms at 50 Hz and 8.33 ms at 60 Hz, with an 80 ms step response to 99% of full scale.

Does it detect a disconnected transmitter?

Yes, wire-off detection is provided per channel.

What accuracy is published?

0.1% of full scale at 20 deg C.


Data sources. Technical values on this page come from Rockwell publication 1794-SG002 (FLEX I/O Selection Guide, Table 19 and Table 21) and 1794-IN093. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

The HART input module with and without channel isolation

This page is the HART analog input module without channel isolation, and this site carries the isolated version beside it under a catalog number one character away. The table is the two records row by row, because eight channels and the same 190 mA supply draw make them look interchangeable.

Row1794-IE8H, this page1794-IF8IH on this site
ApplicationFLEX I/O HART analog inputFLEX I/O HART isolated analog input
Channels8, HART enabled, one field device per channel8, isolated channel to channel, one HART device per channel
Input ranges0...20 mA, 4...20 mA4...20 mA, 0...20 mA, default 0...20 mA
Resolution16 bits16 bits unipolar, 15 bits plus sign bipolar, 0.320 and 0.640 uA per count
Conversion10 ms at 50 Hz, 8.33 ms at 60 Hz4.17, 10.0, 16.7, 19.6, 62 and 470 Hz
Step response80 ms to 99% of full scale480 ms down to 4 ms, depending on the rate
Accuracy0.1% of full scale at 20 deg C0.1% of full scale at 25 deg C
Isolation50 V continuous, basic insulation, no channel isolation120 V continuous basic, 1000 V AC for 60 s channel to channel
External supply190 mA at 24 V DC190 mA at 24 V DC
Power dissipation3.9 W, 13.5 BTU/hr4.8 W at 31.2 V DC, 6.8 BTU/hr
Operating temperature-20...55 deg C0...55 deg C
NetworkControlNet or EtherNet/IP adapter only1794 terminal base, adapter driven

The isolation row is the difference: 50 V basic with no channel-to-channel isolation on this page, against 120 V basic and 1000 V AC for 60 s on the isolated module. Two loops fed from separate supplies in one cabinet therefore cannot share this module, and the isolated one costs 0.9 W more and starts 20 °C higher in temperature. That temperature floor is the row an engineer misses: this page runs from -20 °C and the isolated record from 0 °C, so a cold panel can take the non-isolated module and cannot take the isolated one.

Both records print 0.1% of full scale, and neither figure is comparable: this one states it at 20 °C and the isolated one at 25 °C, and the isolated module adds a per-count resolution figure the other omits. A specification sheet that lists both modules at 0.1% is therefore correct and useless at the same time.

What this record does not settle: the HART revision supported, the field device power available per channel, the input resistance, the per-count resolution, the settling behaviour of the HART channel against an analog value, the terminal base part numbers, and any lifecycle field.

The two records together answer a question neither answers alone: eight HART channels are available with and without channel isolation, at the same supply draw, and the price of isolation is 0.9 W of dissipation and a 20 °C temperature floor. A cabinet at 0 °C has one option; a cabinet with separately supplied loops has the other.

Source: the printed attribute rows of 1794-IE8H on this page and of 1794-IF8IH on this site, quoted row by row, including the isolation, temperature, power and conversion rows that the comparison turns on.

Related numbers

Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)