The 1794-IE8H is the HART-enabled eight-channel analog input card: 16-bit resolution, 0...20 mA or 4...20 mA, wire-off detection on every channel, and one HART field device per channel.
The HART modem is the whole point: the same pair of wires that carries the 4...20 mA loop carries the configuration and diagnostics of the transmitter, so a smart transmitter can be commissioned without a separate handheld.
| 1794-IE8 | 8-channel analog input module | IN STOCK |
| 1794-IE8XT | 8-channel analog input module, extended temperature | IN STOCK |
| 1794-IE8H | 8-channel HART analog input module | IN STOCK |
| 1794-IE12 | 12-channel analog input module | IN STOCK |
| 1794-IE12K | 12-channel analog input module, conformal coated | IN STOCK |
| 1794-IF4I | 4-channel isolated analog input module | IN STOCK |
| 1794-IF4IXT | 4-channel isolated analog input, extended temperature | IN STOCK |
| 1794-IF4ICFXT | 4-channel isolated analog input, conformal coated | IN STOCK |
| 1794-IF8IH | 8-channel HART isolated analog input module | IN STOCK |
| 1794-IR8 | 8-channel RTD input module | IN STOCK |
| 1794-IRT8 | 8-channel thermocouple/RTD input module | IN STOCK |
| 1794-IRT8XT | 8-channel thermocouple/RTD input, extended temperature | IN STOCK |
| 1794-IT8 | 8-channel thermocouple/mV input module | IN STOCK |
| 1794-IE8XOE4 | 8-input, 4-output analog combination module | IN STOCK |
| 1794-IE4XOE2 | 4-input, 2-output analog combination module | IN STOCK |
| 1794-IF2XOF2I | 2-input, 2-output isolated analog combination module | IN STOCK |
| 1794-OE4 | 4-channel analog output module | IN STOCK |
| 1794-OE12 | 12-channel analog output module | IN STOCK |
Application |
FLEX I/O HART analog input, 1794 terminal base |
Cat Num |
1794-IE8H |
Brand Name |
Rockwell |
Channels |
8, HART enabled, one field device per channel |
Input range |
0...20 mA, 4...20 mA |
Resolution |
16 bits |
Conversion rate |
10 ms at 50 Hz, 8.33 ms at 60 Hz |
Step response |
80 ms to 99% of full scale |
Accuracy |
0.1% of full scale at 20 deg C |
Isolation |
50V continuous, basic insulation; no channel isolation |
External supply current |
190 mA at 24V DC |
Power dissipation |
3.9 W (13.5 BTU/hr) |
Network |
ControlNet or EtherNet/IP adapter only |
Operating temperature |
-20...55 deg C |
Same-family catalog numbers: 1794-IE8, 1794-IE8XT, 1794-IE12, 1794-IE12K. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1794 family.
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
One HART field device per channel is the published limit; sharing a single device across two channels is not supported.
ControlNet or EtherNet/IP adapter only — the HART data path needs an adapter that carries it, and a Remote I/O adapter does not.
16-bit resolution on a 0...20 mA loop gives roughly 0.3 uA per count, far finer than the 12-bit general-purpose card.
Wire-off detection per channel reports a disconnected transmitter to the controller instead of a plausible zero reading.
Conversion rate is 10 ms at 50 Hz and 8.33 ms at 60 Hz, tied to the line frequency because the converter integrates over a mains cycle.
Step response to 99% of full scale is 80 ms — slower than the 12-bit card's 18.2 ms to 63%, and the difference matters in a fast control loop.
HART communication does not stop the analog update; the digital signal is superimposed on the loop current and the card decodes it in parallel.
The pairing of 50/60 Hz selection with the line frequency is a commissioning setting, not an automatic one on every adapter.
190 mA at 24V DC is the module consumption, noticeably more than the 60 mA of the non-HART eight-channel card.
3.9 W (13.5 BTU/hr) is the dissipation to add to the enclosure calculation, and it is higher for the same channel count because of the HART circuitry.
The card does not supply loop power for the transmitter; a HART transmitter still needs its 24V loop supply in the panel.
-20...55 deg C operating range with the 75 mm depth of the HART module, against 53 mm for the standard analog cards.
A 4...20 mA transmitter on channel 1 lands on the current terminals with the loop supply in series; the HART signal rides on the same pair.
The module is single-ended, so the loop return is the module common and a grounded transmitter can create a ground loop the card cannot break.
Shielded twisted pair for the loop is the normal practice; HART signalling is low-level and shares the cable with the 4...20 mA step changes.
Configuration changes are possible in RUN mode, which is how a range change on a live transmitter is made without stopping the process.
Smart transmitter installations where the HART diagnostics are wanted in the control system rather than on a handheld.
Panels with many loops and few spare parts — one card covers eight transmitters and reports which one is disconnected.
Not for fast loops. An 80 ms step response excludes fast pressure or flow control; the 1794-IF4I is the faster isolated alternative.
Not for thermocouples. HART is a 4...20 mA protocol; temperature inputs need the 1794-IRT8 or 1794-IT8.
How many HART channels has the 1794-IE8H?
Eight, with one HART field device per channel.
Which networks support it?
ControlNet or EtherNet/IP adapters; the HART data path is not carried by a Remote I/O adapter.
What is the resolution?
16 bits on a 0...20 mA or 4...20 mA input.
How fast is the update?
10 ms at 50 Hz and 8.33 ms at 60 Hz, with an 80 ms step response to 99% of full scale.
Does it detect a disconnected transmitter?
Yes, wire-off detection is provided per channel.
What accuracy is published?
0.1% of full scale at 20 deg C.
This page is the HART analog input module without channel isolation, and this site carries the isolated version beside it under a catalog number one character away. The table is the two records row by row, because eight channels and the same 190 mA supply draw make them look interchangeable.
| Row | 1794-IE8H, this page | 1794-IF8IH on this site |
| Application | FLEX I/O HART analog input | FLEX I/O HART isolated analog input |
| Channels | 8, HART enabled, one field device per channel | 8, isolated channel to channel, one HART device per channel |
| Input ranges | 0...20 mA, 4...20 mA | 4...20 mA, 0...20 mA, default 0...20 mA |
| Resolution | 16 bits | 16 bits unipolar, 15 bits plus sign bipolar, 0.320 and 0.640 uA per count |
| Conversion | 10 ms at 50 Hz, 8.33 ms at 60 Hz | 4.17, 10.0, 16.7, 19.6, 62 and 470 Hz |
| Step response | 80 ms to 99% of full scale | 480 ms down to 4 ms, depending on the rate |
| Accuracy | 0.1% of full scale at 20 deg C | 0.1% of full scale at 25 deg C |
| Isolation | 50 V continuous, basic insulation, no channel isolation | 120 V continuous basic, 1000 V AC for 60 s channel to channel |
| External supply | 190 mA at 24 V DC | 190 mA at 24 V DC |
| Power dissipation | 3.9 W, 13.5 BTU/hr | 4.8 W at 31.2 V DC, 6.8 BTU/hr |
| Operating temperature | -20...55 deg C | 0...55 deg C |
| Network | ControlNet or EtherNet/IP adapter only | 1794 terminal base, adapter driven |
The isolation row is the difference: 50 V basic with no channel-to-channel isolation on this page, against 120 V basic and 1000 V AC for 60 s on the isolated module. Two loops fed from separate supplies in one cabinet therefore cannot share this module, and the isolated one costs 0.9 W more and starts 20 °C higher in temperature. That temperature floor is the row an engineer misses: this page runs from -20 °C and the isolated record from 0 °C, so a cold panel can take the non-isolated module and cannot take the isolated one.
Both records print 0.1% of full scale, and neither figure is comparable: this one states it at 20 °C and the isolated one at 25 °C, and the isolated module adds a per-count resolution figure the other omits. A specification sheet that lists both modules at 0.1% is therefore correct and useless at the same time.
What this record does not settle: the HART revision supported, the field device power available per channel, the input resistance, the per-count resolution, the settling behaviour of the HART channel against an analog value, the terminal base part numbers, and any lifecycle field.
The two records together answer a question neither answers alone: eight HART channels are available with and without channel isolation, at the same supply draw, and the price of isolation is 0.9 W of dissipation and a 20 °C temperature floor. A cabinet at 0 °C has one option; a cabinet with separately supplied loops has the other.
Source: the printed attribute rows of 1794-IE8H on this page and of 1794-IF8IH on this site, quoted row by row, including the isolation, temperature, power and conversion rows that the comparison turns on.
Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.