Product Details:
Payment & Shipping Terms:
|
The 1794-TB3GK is the coated grounded screw clamp base: 36 I/O, 2 common, 2 +V, and 10 chassis ground terminals.
It is the 1794-TB3G with the K coating, which is what an analog island needs when the cabinet is cold rather than the mounting being vibration-prone.
| 1794-TB2 | 16-terminal cage clamp base, 2-wire, up to 132V AC | IN STOCK |
| 1794-TB3 | 16-terminal cage clamp base, 3-wire devices | IN STOCK |
| 1794-TB3S | 16-terminal spring clamp base, 3-wire devices | IN STOCK |
| 1794-TB32 | 32-terminal cage clamp base for 32-point modules | IN STOCK |
| 1794-TB32S | 32-terminal spring clamp base for 32-point modules | IN STOCK |
| 1794-TB3T | temperature base with two cold junction compensation sets | IN STOCK |
| 1794-TB3TS | spring clamp temperature base with CJC sets | IN STOCK |
| 1794-TB3G | grounded screw clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TB3GS | grounded spring clamp base, 36 I/O, 10 chassis ground | IN STOCK |
| 1794-TBKD | cage clamp base with 16 knife disconnects | IN STOCK |
| 1794-TBN | NEMA-style screw clamp base, up to 264V AC/DC | IN STOCK |
| 1794-TBNF | fused NEMA-style base, eight 5 x 20 mm fuses | IN STOCK |
| 1794-TB37DS | 37-pin D-shell termination for digital and analog modules | IN STOCK |
| 1794-TB62DS | 62-pin D-shell termination for digital and analog modules | IN STOCK |
Application |
FLEX I/O grounded terminal base for analog modules |
Cat Num |
1794-TB3GK |
Brand Name |
Rockwell |
Termination |
Grounded screw clamp, 36 I/O, 2 common, 2 +V, 10 chassis ground |
Wire size |
0.34...3.3 mm2 (22...12 AWG), 75 deg C or greater |
Current capacity |
10 A maximum |
Wiring category |
2 |
Dimensions |
94 x 94 x 69 mm |
Operating temperature |
-20...70 deg C |
Coating |
Conformal |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
36 I/O, 2 common, 2 +V and 10 chassis ground, screw terminated.
10 A current capacity with 22...12 AWG wire, category 2 wiring.
-20...70 deg C and the conformal coating of the K catalog.
94 x 94 x 69 mm footprint, unchanged from the uncoated 1794-TB3G.
Ten chassis terminals for per-channel-pair shields, the defining feature of the grounded base.
Rail must be zinc-plated, yellow-chromated steel for the chassis path.
Otherwise use the base mounting holes with star-washer screws, or the 1794-NM1 kit.
Coating does not replace grounding; the shield path still has to be built.
Coated analog islands built with -XT analog modules.
Panels where screw termination is the site standard, avoiding a mixed termination style.
Not for discrete I/O; 2 common and 2 +V cannot wire 16 points comfortably.
Not spring; the 1794-TB3GSK is the spring equivalent with the same counts.
35 x 7.5 mm DIN rail with 25 mm clearance.
1794-NM1 panel mount kit with 18 screws where rail is unavailable.
1492-EA35 rail locks for vertical or high-vibration use.
One end cap per system; bases form the backplane by plugging together.
Coated analog racks with screw termination.
Cold cabinets where a heater is not an option.
Not for uncoated modules; pair it with -XT parts.
Not for thermocouples; the 1794-TB3TK carries the CJC sets.
What does the 1794-TB3GK provide?
A conformally coated grounded screw clamp base with 36 I/O and 10 chassis ground terminals.
How is it different from the 1794-TB3G?
Conformal coating only; the terminal pattern and ratings match.
What is the current capacity?
10 A maximum.
What wire size does it accept?
0.34...3.3 mm2 (22...12 AWG), 75 deg C or greater.
Does the coating affect grounding?
No; the 10 chassis terminals still need a proper shield path.
What is the operating temperature?
-20...70 deg C.
1794-TB3GK is a FLEX I/O terminal base unit, not an I/O module. It is the part that carries the field terminals, plugs into the adjacent base to form the backplane, and holds the module on top. The termination type here is Grounded screw clamp with 36 I/O, 2 common, 2 +V, 10 chassis ground.
| Attribute | Value |
| Catalog number | 1794-TB3GK |
| Termination type | Grounded screw clamp |
| Connections | 36 I/O, 2 common, 2 +V, 10 chassis ground |
| Current capacity, maximum | module dependent |
| Wiring category | module dependent |
| Field voltage | Per module |
| Operating temperature | -20...+70 C |
| Purpose in the range | The conformal coated version of the 1794-TB3G. |
The conductor range for this base is 0.21 to 1.3 mm2 (24 to 16 AWG) stranded copper rated 105 C or greater, with 1.2 mm maximum insulation, with a maximum current capacity of module dependent across the base. Those figures are the base rating and not the module rating: a 16 point module on a 10 A base is still limited by the module output current per channel.
Selecting a base is a compatibility step, not a preference step. The module data sheet names the bases that are permitted for it, and a base outside that list may key differently, may not carry the required common and voltage terminals, or may not be rated for the field voltage of the module.
The wiring category matters as much as the gauge: category 2 bases are the general field wiring class, while grounded bases in the 1794-TB3G family carry 10 chassis ground terminals for analog and temperature modules where a separate signal common is needed.
One point about the 24V DC digital slices that catches panel builders: the adapter supplies the field power for the modules on its own 24V output, and that output is current limited. On a 1794-ADN the supply output is 450 mA at 24V, so a slice of 16 point DC modules can exhaust the adapter before the cabinet is half filled, and a separate field supply has to be introduced rather than assumed.
Temperature class is written per module and per base, and the lower of the two governs the slice. A 70 C base carrying a 55 C module is a 55 C slice, which is why the extended temperature modules exist as a matched set rather than as an upgrade to one part of the pair.
The 22 to 12 AWG acceptance range on the standard bases is wider than the field device terminals in most panels, so the practical constraint is usually the device end, not the base end. Where a 24V DC sensor cable is 18 AWG and the base accepts 12 AWG, the conductor still has to be torqued to the published value rather than to feel.
Conformal coating on a K suffix base is applied to the assembled board and not to the terminals, so the coating protects the electronics against condensation while the field terminals remain serviceable. That is the point of ordering the coated base instead of sealing the whole enclosure.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
The Allen-Bradley Flex I/O 1794 modules category lists the related catalog numbers, options and accessories for this range.