logo
Home ProductsAB CompactLogix 1769

Allen Bradley PLC 1769-IM12 / 1769IM12

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1769-IM12 / 1769IM12

China Allen Bradley PLC 1769-IM12 / 1769IM12 supplier
Allen Bradley PLC 1769-IM12 / 1769IM12 supplier Allen Bradley PLC 1769-IM12 / 1769IM12 supplier Allen Bradley PLC 1769-IM12 / 1769IM12 supplier Allen Bradley PLC 1769-IM12 / 1769IM12 supplier Allen Bradley PLC 1769-IM12 / 1769IM12 supplier

Large Image :  Allen Bradley PLC 1769-IM12 / 1769IM12

Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1769-IM12 / 1769IM12

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $148.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1769-IM12 technical data PDF download CompactLogix 1769-IM12 / 1769IM12 12-Point 240V AC Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1769-IM12 (also written 1769IM12) is the 200/240V AC input of the Compact I/O 1769 range: twelve points on one internally connected common, reading 230V control circuits directly — European and Asian panels where the control voltage is phase-to-neutral mains rather than 120V.

Twelve points, not sixteen, is the detail that catches people: the 1769-IM12 physically has sixteen terminal positions but four are marked NC and must not be used as a connection. A panel wired on the assumption of a full sixteen gets four dead terminals.

1769-IA16 Compact 16-point 120V AC input module IN STOCK
1769-IQ16 Compact 16-point 24V DC sink/source input module IN STOCK
1769-IQ32 Compact 32-point 24V DC sink/source input module IN STOCK
1769-OA16 Compact 16-point 120/240V AC output module IN STOCK
1769-OB16 Compact 16-point 24V DC output module IN STOCK
1769-OB32 Compact 32-point 24V DC output module IN STOCK
1769-OW16 Compact 16-point relay output module IN STOCK
1769-IF4 Compact 4-channel analog input module IN STOCK
1769-IF8 Compact 8-channel analog input module IN STOCK
1769-IF16C Compact 16-channel current input module IN STOCK
1769-OF4 Compact 4-channel analog output module IN STOCK
1769-OF8V Compact 8-channel voltage output module IN STOCK
1769-OF8C Compact 8-channel current output module IN STOCK
1769-ARM Compact address reserve module IN STOCK

Product Specifications 1769-IM12 (PDF)
 Application
 Compact I/O, 1769 bus
 Cat Num
 1769-IM12
 Brand Name
 Rockwell
 Inputs
 12 (12 points per group, commons connected internally)
 Voltage category
 200/240V AC
 Operating voltage range
 159…265V AC, 47…63 Hz
 Input delay, on / off
 20 ms / 20 ms
 Current draw @ 5.1V
 100 mA
 Heat dissipation, max
 3.65 W
 Off-state voltage / current
 40V AC max / 2.5 mA max
 On-state voltage / current
 159V AC min / 5 mA @ 74V AC min, 12 mA @ 120V AC max
 Inrush current, max
 250 mA
 Input impedance, max
 27 kΩ @ 50 Hz; 23 kΩ @ 60 Hz
 Isolation
 1836V AC 1 s or 2596V DC 1 s, point to bus; 132V AC working voltage
 Slot width / weight
 1 slot / 300 g
 Power supply distance
 8 modules

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1769-TD006 (module specifications) and 1769-SG001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1769-IM12 Compact I/O 12-point 240V AC input module, factory packaging 1769-IM12 module, front view with terminal block 1769-IM12 label detail showing catalog number

Where the module sits in a CompactLogix system

Bank and supply. 100 mA at 5.1V, 3.65 W, one slot, eight-module distance rating, powered from the bank's 1769-PA2 / PB2 / PA4 / PB4. One common, twelve points. All twelve share an internally connected AC common, so a second 230V feed requires another module or an interface relay. Voltage window. 159…265V AC at 47…63 Hz. A nominal 220V circuit at the bottom of its tolerance — 187V, say — is still inside, but a 230V feed that sags under 159V drops the point. Four NC terminals. The published wiring diagram marks them NC and states they must not be used. Loop them out of the drawing explicitly so a field technician does not land a wire there.

Input behaviour that decides field wiring

Impedance is much higher than the 120V modules. 27 kΩ at 50 Hz and 23 kΩ at 60 Hz against 12 kΩ/10 kΩ on the 1769-IA16 — the module draws less current at 240V, and it also leaks less through a given stray capacitance, which is why long 230V runs behave better here. Off-state is 40V AC. Twice the 120V modules' 20V limit, matched to the higher line voltage; the 2.5 mA off-state current and 5 mA minimum on-state current are unchanged, so the leakage-versus-minimum-current rule still applies. 20 ms on and off. Fixed, same as the rest of the AC input family; unsuitable for anything faster than a 20 ms pulse.

Commissioning in four checks

Confirm the drawing records twelve live points and four NC terminals, and that no field wire lands on NC. Measure the 230V feed at the terminals under load: 159…265V AC at 47…63 Hz, not just at the distribution board. Torque terminals at 0.68 N·m (6 lb·in), retaining screws at 0.46 N·m (4.1 lb·in), 22…14 AWG solid or 22…16 AWG stranded copper rated 90 °C. Verify each of the twelve points against a known pilot device — with a shared common, a mis-wired neutral appears as several points behaving together.

Substituting or replacing a 1769-IM12

1769-IA16 — sixteen points at 120V AC on one common, when the control circuit is 120V rather than 230V. 1769-IA8I — eight isolated 120V AC points, for panels with several separate feeds. 1769-IQ16 — sixteen 24V DC inputs, if the 230V circuit can be reduced to a 24V interface relay. There is no 16-point 240V AC module in the family; twelve is the ceiling for one slice at 230V.

Which Compact I/O AC input to specify

1769-IM12 — 12 points, 200/240V AC, one internal common, 100 mA, four NC terminals. 1769-IA16 — 16 points, 120V AC, 115 mA. 1769-IA8I — 8 points, 120V AC, individually isolated. Field voltage first, then point count, then whether the points share one source — the IM12 is the only 230V option and it is capped at twelve.

FAQ — 1769-IM12

How many inputs does 1769-IM12 have?

Twelve live points on one internally connected common. The module has sixteen terminal positions but four are marked NC and must not be used as connections.

What AC voltage range does 1769-IM12 accept?

159…265V AC at 47…63 Hz, rated 200/240V AC, with a fixed 20 ms on and 20 ms off delay.

What does 1769-IM12 draw from the backplane?

100 mA at 5.1V with 3.65 W maximum heat dissipation, one slot, 300 g, eight-module power-supply distance rating.

Why are four terminals marked NC on 1769-IM12?

The module is built on a sixteen-terminal block but only twelve channels are fitted. The specification states the NC terminals must not be used as a connection.

What is the off-state voltage of 1769-IM12?

40V AC, with 2.5 mA maximum off-state current — twice the voltage limit of the 120V input modules, matched to the 230V line.

Can 1769-IM12 read a 120V AC signal?

No. The minimum on-state voltage is 159V AC, so a 120V circuit never reaches the guaranteed on-state level.


Data sources. Technical values on this page come from Rockwell publication 1769-TD006 (1769 Compact I/O Modules Specifications) and 1769-SG001 (CompactLogix and Compact GuardLogix Systems Selection Guide), both current Rockwell Automation documents. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)