This page documents the 22F-A4P2N103, a PowerFlex 4M (bulletin 22F) drive in the 240 V single-phase class, IP20 panel mount, without integral EMC filter. The rating code 4P2 encodes the output current in amperes, which is 4.2 A for this string; the kW and HP equivalents, the frame letter and the protection row for this code are printed in the drive ratings table of 22F-UM001 and are not reproduced here rather than inferred from a neighbouring rating.
| Field | Value |
| Catalog number | 22F-A4P2N103 |
| Family | 22F - PowerFlex 4M, IP20 panel mount only |
| Voltage code (character 5) | A - 240 V single-phase |
| Rating code (characters 6-8) | 4P2 - 4.2 A continuous output, encoded in the code |
| Enclosure (character 9) | N - IP20 |
| HIM position (character 10) | 1 |
| Emission class (character 11) | 0 - without integral EMC filter |
| Type (character 12) | 3 - carried, resolved in the option appendix |
| kW / HP / frame | published per rating in 22F-UM001, not carried over here |
The 4M carries no branch short-circuit protection inside the drive. Any installation needs input fuses or an input circuit breaker sized from the rating row, and Bulletin 140M/140MT self-protected controllers are accepted upstream without fuses where the panel uses that route. Fuse class is part of the requirement: BS88 parts 1 and 2 or EN60269-1 type gG for IEC installations, Class CC, T or J for UL.
The class-level input window published for this voltage class is 180...265 V, so the installation has to sit inside that band rather than at nominal, and a supply that sags below the lower limit is a trip rather than a derating exercise. On a single-phase 240 V code the output is three-phase: the motor is a three-phase motor, and the input and output phase counts are two separate questions on this family.
Character 11 reads 0, so this drive ships without integral EMC filter. The character does not change the rating or the terminals; it changes the EMC environment the drive may be installed in and the motor cable length the manual permits.
| Filter route | Second environment | First environment, unrestricted distribution |
| Integral filter, 240 V drive | 5 m | 1 m |
| Integral filter, 480 V drive | 10 m | see the same table in 22F-UM001 |
| External S-type filter | 5 m | 1 m |
| External L-type filter | 100 m | 25 m |
Frame A accepts 3.3 mm2 (12 AWG) maximum and 0.8 mm2 (18 AWG) minimum at 1.4...1.6 N.m; frame B accepts 8.4 mm2 (8 AWG) at 1.6...1.9 N.m; frame C accepts 13.3 mm2 (6 AWG) at 2.7...3.2 N.m. The minimum is what decides whether a small motor cable can be landed directly or has to go through a junction, and this rating is small enough that the answer is usually a junction.
Output current is limited in software rather than by the frame: the current-limit parameter defaults to 1.5 times the drive rated amps and can be raised to 1.8 times, and the output-current monitor reads up to twice the rated amps. A drive one frame larger than the motor is therefore made safe for that motor by a parameter setting, and a slower ramp is a parameter rather than a second catalog number.
The same rating and voltage class appear under other strings: 22F-A4P2N113. They differ in the interface or emission characters rather than in the power section, so the choice is made on the panel and the cable route, not on the current.
Reorder risk on the emission character. Two drives with the same rating and different character 11 are different products when the cable run is long. A spare ordered by rating alone can arrive unfiltered into an installation that was commissioned with a filter, and the mismatch shows up as an emission problem rather than as a wrong part number.
The two things a 4m does not contain. The 4M carries no branch short-circuit protection and no integral EMC filter on the unfiltered codes. Both have to be supplied around it: fuses or a circuit breaker upstream, and either the integral filter option or an external filter where the installation is regulated. A panel drawn around a bare 4M is a panel whose protection and emission compliance live in other line items.
Single-phase input, three-phase output. A 240 V single-phase 4M produces three-phase output from a single-phase supply, which is why small conveyors and fans in light-duty panels can use it at all. The motor is still a three-phase motor, and the input and output phase counts are two separate questions on this family.
Filter class decides the motor lead. The emission character does not change the rating, the frame or the terminals; it changes the environment the drive may be installed in and the motor cable length the manual allows. An integral 240 V filter is good for 5 m in the second environment, an integral 480 V filter for 10 m, an external S-type filter for 5 m, and an external L-type filter for 100 m outside the unrestricted first environment.
Frame letters and the wire that fits. Frames A, B and C set both the terminal block and the panel footprint: 12 AWG maximum on frame A, 8 AWG on frame B, 6 AWG on frame C. The minimum sizes matter as much as the maximum, because a small motor cable below the block minimum has to be landed through a junction rather than directly.
Panel thermal and mounting. Estimated watts loss is published per rating at rated load, rated speed and rated PWM and is a drive-only figure used in the panel thermal calculation. Panel mounting is the only form this family publishes, with a 1.9 mm minimum panel thickness and M4 screws at 1.56...1.96 N.m.
The 4M is the small-machine drive in this family, and the tell is in the protection table: it is the drive that does not carry branch short-circuit protection internally, so the panel around it has to supply it.
No price, lead time or lifecycle statement is implied. The decode, the protection requirement and the cable allowances are quoted from the PowerFlex 4M user manual, publication 22F-UM001; figures this publication prints only per rating row are named as such rather than filled in.
This record is placed on the six-record 22F PowerFlex 4M ladder carried on this site. The first table is the rating each record prints or declines to print; the second is the protection and enclosure that follows from it. Both quote only what the individual pages state, and a record whose page refers a field to 22F-UM001 is marked as not printed rather than filled in from a neighbouring rating.
| Catalog number | Voltage class | Output current | Rated power | Frame | Input window | Input kVA / current |
| 22F-A2P5N103 | A - 240 V single-phase | 2.5 A | 0.4 kW (0.5 HP) | A | 180-265 V | 1.6 kVA / 6.5 A |
| 22F-A4P2N103 | A - 240 V single-phase | 4.2 A | not printed - referred to 22F-UM001 | not printed | 180-265 V (class level) | not printed |
| 22F-A4P2N113 | A - 240 V single-phase | 4.2 A | not printed - referred to 22F-UM001 | not printed | 180-265 V (class level) | not printed |
| 22F-B017N103 | B - 240 V three-phase | 17.5 A | 3.7 kW (5.0 HP) | B | 180-265 V | 8.8 kVA / 21.1 A |
| 22F-D018N104 | D - 480 V three-phase | 18.0 A | 7.5 kW (10.0 HP) | C | 340-528 V | 16.3 kVA / 19.5 A |
| 22F-D024N104 | D - 480 V three-phase | 24.0 A | 11.0 kW (15.0 HP) | C | 340-528 V | 21.7 kVA / 26.1 A |
Protection and enclosure that follow. The line fuse is a function of the input current, and the enclosure volume is a function of the frame.
| Catalog number | Line fuse at 40 C | 140M / 140MT upstream | Contactor | Min enclosure volume |
| 22F-A2P5N103 | 10 A | 140M-C2E-C10 / 140MT-C3E-C10 | 100-C09 / 100-E09 | 1,655 in3 |
| 22F-A4P2N103 | not printed - referred to 22F-UM001 | not printed | not printed | not printed |
| 22F-A4P2N113 | not printed - referred to 22F-UM001 | not printed | not printed | not printed |
| 22F-B017N103 | 35 A | 140M-D8E-C25 / 140MT-D9E-C25 | 100-C23 / 100-E26 | 1,655 in3 |
| 22F-D018N104 | 30 A | 140M-F8E-C25 | 100-C23 / 100-E26 | 3,441 in3 |
| 22F-D024N104 | 40 A | 140M-F8E-C32 | 100-C30 / 100-E30 | 3,441 in3 |
Where this record sits: 4.2 A on the 240 V single-phase class, one step above the 2.5 A record and on the same class of input, with the emission character reading 0.
The frame, not the power, sets the mechanical facts. Frames A and B both print a 1,655 cubic inch minimum enclosure volume, and frame C doubles it to 3,441 cubic inches - yet the two frame C records differ by 3.5 kW and stay on the same volume. The terminal range moves the other way at the top: frames A and B accept down to 0.8 mm2 (18 AWG), while frame C bottoms out at 3.3 mm2 (12 AWG) and 2.7-3.2 N.m, so a small motor cable cannot be landed directly on the largest drive in this group.
What these pages do not carry: no enclosure dimensions, only the minimum volume in cubic inches, so the panel layout has to come from the manual; no drive weight; no efficiency, loss or thermal figure; no overload percentage for the thermal model; and on the two 4.2 A records no kW, HP, frame, kVA, input current, fuse, contactor or enclosure volume at all, because those pages deliberately refer the rating row to 22F-UM001 rather than reproduce it.
This record is the one of the pair that carries no rating row at all: the page states the kW, HP and frame for this code are published per rating in 22F-UM001 and are deliberately not reproduced here, so 4.2 A and 240 V single-phase are all the electrical facts on the record. Its twin 22F-A4P2N113 differs in one character only - the emission character - and that character is the whole order difference.
Source: the decode tables and body text printed on the six 22F records on this site, which cite 22F-UM001 for the rating rows, the fuse and enclosure volumes; the output currents, kW and HP figures, input windows, kVA and input currents, terminal ranges, torques, fuse ratings, 140M/140MT and contactor part numbers, enclosure volumes and DC fuse numbers are quoted from the records that print them, and fields a record refers to the manual are shown as not printed.
Twelve of the 34 22F records carried on this site, ordered by how close their codes sit to this one. This page is 22F-A4P2N103.