Product Details:
Payment & Shipping Terms:
|
The 1734-TOP is a 8-terminal POINT I/O wiring base with a screw-clamp removable terminal block: the base mounts on the DIN rail, the I/O module snaps into it, and integrated one-piece block carries the field wiring.
One piece instead of two: the wiring block is part of the base, so there is no separate RTB to stock, lose, or fit twice.
| 1734-TB | 8 terminal wiring base with removable screw-clamp RTB | IN STOCK |
| 1734-TB3 | 12 terminal wiring base with removable screw-clamp RTB3 | IN STOCK |
| 1734-TB3S | 12 terminal wiring base with removable spring-clamp RTB3S | IN STOCK |
| 1734-TOP | 8 terminal one-piece base, screw-clamp | IN STOCK |
| 1734-TOPS | 8 terminal one-piece base, spring-clamp | IN STOCK |
| 1734-TOP3 | 12 terminal one-piece base, screw-clamp | IN STOCK |
| 1734-TOP3S | 12 terminal one-piece base, spring-clamp | IN STOCK |
| 1734-CTM | Common terminal module, 2 A per point, 4 A per module | IN STOCK |
Number of terminations |
8 |
Termination type |
screw-clamp |
Wiring block |
integrated one-piece block |
Field power bus supply voltage |
28.8V DC, 120/240V AC |
Field power bus supply current, max |
10 A |
Signal terminal voltage, max |
28.8V DC, 120/240V AC |
Signal terminal current, max |
2 A |
Wire size |
0.25...2.5 mm2 (22...14 AWG), 75 deg C or greater, 1.2 mm insulation max |
Dimensions, HxWxD |
49 x 12 x 144 mm |
Weight, approx |
63.8 g |
Enclosure type rating |
None (open-style) |
Temperature, operating |
Dependent on the installed module, -20...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN028 (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The pinout follows the digital pattern - channel pairs on 0...3, common on 4/5, supply on 6/7 - but there is no removable block. Wiring is done in place on the installed base, which is faster to build and slower to service than a two-piece assembly.
63.8 g and 49 x 12 x 144 mm. The one-piece base sits lower than the two-piece assembly because the RTB handle is gone, which matters in a shallow enclosure where the rail sits close to the door.
On a machine built in series, where the wiring is done once by the same crew: fewer part numbers, less inventory, no RTB to mis-key. On a retrofit where slices get swapped under power-off pressure, the removable block is worth the extra 20 g.
Field power bus 10 A and signal terminals 2 A, at 28.8V DC or 120/240V AC. The 10 A figure is the bus capacity that the 1734-EP24DC and 1734-FPD modules are built around; the 2 A is per signal terminal, which is why an output slice rated 2 A per point uses the base at its limit rather than in the middle of its range. Isolation and voltage segregation come from the module that sits in the base, not from the base itself - the base is a passive wiring carrier.
Rockwell's removal sequence is explicit: remove the module in the base, then the module in the base to the right, then the RTB, then release the orange base locking screw and lift straight up. The base to the right has to come out because the interlocking side pieces and the POINTBus contacts overlap. Pulling a base with power applied interrupts the backplane and can cause unintended machine motion.
What does one-piece mean on 1734-TOP?
The wiring block is integrated into the base; there is no separate 1734-RTB to fit.
How many terminals and what pinout?
Eight: 0/1 channel 0, 2/3 channel 1, 4/5 common, 6/7 field supply.
What are its dimensions and weight?
49 x 12 x 144 mm and 63.8 g, lighter and shorter than the two-piece 1734-TB assembly.
What current rating applies?
10 A field power bus and 2 A per signal terminal, at 28.8V DC or 120/240V AC.
Is it compatible with 1734-TB modules?
Yes - the same I/O modules snap into it; only the termination style differs.
1734-TOP is a POINT I/O terminal base assembly: a DIN-rail mounting base with a 8-terminal RTB, tall base profile. The base is ordered separately from the I/O module because the base and the RTB are the parts that carry the wiring, and the module is the part that is replaced on failure.
| Attribute | Value |
| Catalog number | 1734-TOP |
| Assembly type | 8-terminal RTB, tall base profile |
| Replacement RTB | 1734-RTB |
| Dimensions, H x W x D | 144.0 x 13.8 x 78.6 mm (5.67 x 0.54 x 3.09 in.) |
| Weight | 63.79 g (2.25 oz) |
| RTB function | All field terminations, removable without disturbing wiring |
| Terminal numbering | Marked on the bottom of the RTB |
| Related base | 1734-TBCJC adds cold junction compensation for 1734-IT2I |
Terminal count decides the base, not the module width: the eight-terminal bases suit modules with one termination per channel, and the twelve-terminal bases are needed where the module presents commons or shield returns in addition to the channel terminals. A two-point analog module needs a shield ground terminal point, which is why the analog side of the family runs on the wider bases.
The terminal base assembly is the part that makes POINT I/O modular: the base mounts on the DIN rail, the removable terminal block (RTB) carries every field termination, and the I/O module plugs onto both. The RTB is ordered with the base as one unit, and a spare RTB is a field-replaceable part rather than a whole new base.
Each terminal point is numbered on the bottom of the RTB, which is why a wiring fault can be traced from the drawing to a numbered terminal instead of to a wire colour. Once the RTB is wired, the block separates from the base and the module without disturbing the terminations, so a module swap does not require re-terminating a single field wire.
Every POINT I/O module mounts in a terminal base that is ordered separately, and the number of field terminals on the base has to match the module: eight terminals for single-point-per-channel digital modules, twelve where the module needs a common or a shield return per channel group.
Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.
The system is rated for panel work rather than for a lab bench: modules plug onto bases that are already wired, the RTB stays on the wiring while the electronics come off, and the same base family accepts the next module of the same width. That is the reason a spare part for POINT I/O is usually an RTB or a base rather than a module, and why a maintenance stock built only from modules is incomplete.
Related models, options and spare parts for this range are listed in the Allen-Bradley POINT I/O 1734 modules category.