The 1734-IK counts or measures frequency up to 1 MHz from a single encoder, pulse generator or mechanical limit switch, and returns the value as a 24-bit number inside a 32-bit long word.
It behaves as a signal conditioner, a function block and a counter in one slice. The count is available to the controller without a separate high-speed counter card, which is the reason these modules survive in retrofits where a dedicated card slot no longer exists.
| 1734-IJ | 1-channel incremental encoder input, 5V DC differential, 1.0 MHz | IN STOCK |
| 1734-IK | 1-channel incremental encoder input, 24V DC differential, 1.0 MHz | IN STOCK |
Number of counters |
1 |
Input frequency, max |
1.0 MHz in counter and encoder X1 modes (no filter); 500 kHz encoder X2; 250 kHz encoder X4 |
Voltage category, input |
24V DC, A/Areturn, B/Breturn, Z/Zreturn |
Voltage, on-state, min |
12.5V DC |
Current, on-state, min |
5 mA |
Current, on-state, max |
10.2 mA @ 24V DC or 6.1 mA @ 15V DC |
Voltage, off-state, max |
1.8V DC |
Current, off-state, max |
0.250 mA |
Input filter selections |
Off, 10 us (50 kHz), 100 us (5 kHz), 1.0 ms (500 Hz), 10.0 ms (50 Hz) |
Counter range |
24-bit, 0...16,777,215, returned in a 32-bit word |
Operating modes |
Counter, Encoder X1, Encoder X2, Encoder X4, Period/Rate, Rate Measurement |
Power dissipation, max |
1.5 W @ rated load |
Thermal dissipation, max |
5.1 BTU/hr @ rated load |
Isolation voltage |
50V (continuous), basic insulation, type tested at 1100V DC for 60 s, field side to system |
External DC supply |
No additional external power required to power the module |
Terminal base |
1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS |
Keyswitch position |
2 |
Dimensions, HxWxD |
56 x 12 x 75.5 mm |
Temperature, operating |
-20...55 deg C (-4...131 deg F) |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-UM006B-EN-P (module specifications) and 1734-SG001E-EN-P (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Counter mode takes single-phase pulses on channel A and uses channel B only for direction - B high counts down, B low or floating counts up. Encoder mode expects two-phase quadrature and counts on the relationship between A and B. Tying B high or low gives a unidirectional count without wasting an encoder channel.
1.0 MHz in counter and X1 modes; 500 kHz in X2; 250 kHz in X4. A 2500-line encoder read in X4 produces 10,000 counts per revolution but caps the mechanical speed at 250 kHz, so a fast axis is better counted in X1 or X2 and scaled in the controller rather than pushed through X4.
Period/Rate gates an internal 5 MHz clock with the incoming signal and returns both frequency and accumulated count. The readable frequency ceiling in this mode is 200 Hz times the scalar value, so a scalar of 128 tops out near 25 kHz. Rate Measurement samples over a user period of 10 ms to 3 s and returns the count for that window plus the frequency - the right mode for a slow, noisy flow meter.
Off, 50 kHz, 5 kHz, 500 Hz and 50 Hz, selectable per A, B and Z group. A 10 ms filter at 50 Hz is the default and is the correct setting for a mechanical switch on a conveyor; it is useless for a servo feedback encoder, where the filter must be off and the cable shielded.
The module needs no additional external power - it is fed from the POINTBus and its field supply through the base. Isolation is 50V basic, type tested at 1100V DC for 60 s, so encoder cable should be treated as a signal circuit, not as a field circuit with 250V segregation. Keyswitch position 2, TB, TBS, TOP or TOPS base.
What input voltage does 1734-IK accept?
24V DC nominal, on-state from 12.5V DC with the derating curve applying at the top of the range; 5V encoders need the 1734-IJ instead.
How much current does an input draw?
10.2 mA at 24V DC or 6.1 mA at 15V DC in the on state, minimum 5 mA, with 0.250 mA maximum off-state leakage.
What is the maximum counting frequency?
1.0 MHz counter and X1, 500 kHz X2, 250 kHz X4, all with the filter off.
How much heat does it add?
1.5 W at rated load, 5.1 BTU/hr - 0.4 W more than the 5V version because of the higher input threshold.
Can it replace a standalone counter card?
For a single axis up to 1 MHz, yes: the count is produced on the POINTBus and read by the controller without a separate high-speed counter module.
1734-IK is a POINT I/O mounting and wiring accessory in the POINT I/O family. It mounts on a terminal base assembly that is ordered separately, connects to the POINTBus through the base, and presents its field wiring on the removable terminal block.
| Attribute | Value |
| Catalog number | 1734-IK |
| Module type | POINT I/O mounting and wiring accessory |
| POINTBus current requirement | see module it serves |
| Module width | 12.1 mm (0.48 in.) standard, 24.1 mm (0.94 in.) for safety modules |
| Terminal base | Ordered separately: 1734-TB/TBS (8 terminal) or 1734-TB3/TB3S (12 terminal) |
| Module dimensions | 77.5 x 12.1 x 56.6 mm (3.05 x 0.48 x 2.23 in.), weight approx. 31-36 g |
POINTBus current is the budget that decides how many modules a slice can carry: most digital and analog modules draw 75 mA, the 1734-OW2 draws 80 mA, and 1734-IB4D draws 50 mA. The usable current of the adapter, plus that of any expansion power supply, divided by the per-module draw gives the maximum slice length, and that is a planning calculation rather than a rule of thumb.
Every POINT I/O module mounts in a terminal base that is ordered separately, and the number of field terminals on the base has to match the module: eight terminals for single-point-per-channel digital modules, twelve where the module needs a common or a shield return per channel group.
Sink/source and AC-input variants exist because the field device decides the wiring, not the module preference: a sinking input expects the field device to switch to the positive rail, a sourcing input expects it to switch to common, and an isolated AC input exists so that a shared common between channels does not create a path between two different field circuits.
Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.
Each terminal point is numbered on the bottom of the RTB, which is why a wiring fault can be traced from the drawing to a numbered terminal instead of to a wire colour. Once the RTB is wired, the block separates from the base and the module without disturbing the terminations, so a module swap does not require re-terminating a single field wire.
Related models, options and spare parts for this range are listed in the Allen-Bradley POINT I/O 1734 modules category.