logo
Home ProductsAB POINT I/O 1734

Allen Bradley PLC 1734-IE4S / 1734IE4S

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1734-IE4S / 1734IE4S

China Allen Bradley PLC 1734-IE4S / 1734IE4S supplier
Allen Bradley PLC 1734-IE4S / 1734IE4S supplier Allen Bradley PLC 1734-IE4S / 1734IE4S supplier Allen Bradley PLC 1734-IE4S / 1734IE4S supplier Allen Bradley PLC 1734-IE4S / 1734IE4S supplier Allen Bradley PLC 1734-IE4S / 1734IE4S supplier Allen Bradley PLC 1734-IE4S / 1734IE4S supplier

Large Image :  Allen Bradley PLC 1734-IE4S / 1734IE4S

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1734-IE4S / 1734IE4S

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $538.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1734-IE4S technical data PDF download POINT Guard I/O 1734-IE4S / 1734IE4S 4-Channel Safety Analog Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT Guard I/O Safety Input

The 1734-IE4S is not a general-purpose analog input: it is a POINT Guard I/O safety analog input rated up to SIL CL 3 and PLe Cat. 4, for GuardLogix, Compact GuardLogix and SmartGuard controllers. It reads four voltage or current sensors with seven configurable ranges and powers them from individually current-limited, monitored sensor outputs.

It occupies two terminal bases - a physical requirement of the POINT Guard architecture - and uses keyswitch positions 8 and 3, which is the first thing to check when someone tries to drop it into a spare single base.

1734-IE2C 2 analog current inputs, 4...20 mA, 16 bits over 0...21 mA, 60 ohm IN STOCK
1734-IE2V 2 analog voltage inputs, 0...10V or +/-10V, 15 bits plus sign, 100 kOhm IN STOCK
1734-IE4S 4 analog inputs, 0...20 mA / 0...10V, 16 bits, isolated IN STOCK
1734-IE8C 8 analog current inputs, 4...20 mA, 16 bits IN STOCK

Product Specifications 1734-IE4S (PDF)
 Number of inputs
 4 safety analog inputs, voltage or current, single-ended non-isolated
 Input ranges
 Seven configurable ranges, including +/-10V, +/-5V, 0...5V, 0...10V, 4...20 mA and 0...20 mA
 Input values
 +/-10V DC voltage, 0...20 mA current
 Sensor outputs
 24V DC, 150 mA max per sensor output @ 55 °C, individually current-limited and monitored
 Field power
 19.2...28.8V DC, 65 mA, Class 2
 Backplane current
 5V DC, 110 mA
 Isolation voltage
 50V continuous, basic insulation between field side and system, no isolation between channels, tested per UL 61010-1
 Safety rating
 Up to SIL CL 3 (IEC 61508, IEC 61511, IEC 62061) and PLe, Cat. 4 (ISO 13849-1)
 Terminal bases
 Two terminal bases per module: 1734-TB or 1734-TBS, or 1734-TOP, 1734-TOPS, 1734-TOP3, 1734-TOP3S
 Keyswitch
 8 (left), 3 (right)
 Indicators
 1 yellow lock status, 1 green/yellow power status, 4 channel status
 Temperature code
 T4
 Wire type
 Shielded on signal ports
 Operating temperature
 -20...55 °C, surrounding air 55 °C max

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN016-EN-P (module specifications) and 1734-UM013 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-IE4S original product photograph, wide view 1734-IE4S original product photograph, label view 1734-IE4S original product photograph, second unit

A safety module, not a process input

Certified to SIL CL 3 and PLe Cat. 4, the module is wired into a safety task and reports channel diagnostics that the safety controller uses to reach the required diagnostic coverage. It is not a substitute for 1734-IE2C in a standard task, and it cannot be used with a non-safety adapter.

Two bases per module

Each POINT Guard module needs two terminal bases: 1734-TB or 1734-TBS, or the one-piece 1734-TOP, 1734-TOPS, 1734-TOP3 or 1734-TOP3S. Rockwell specifically says do not use 1734-TB3 or 1734-TB3S. The module spans both bases, which changes the slice count in the panel layout and the wiring space available per channel.

Sensor power is monitored

Four sensor outputs at 24V DC, 150 mA maximum each at 55 °C, individually current-limited and monitored. A shorted sensor lead is detected at the supply, not only at the signal, and that diagnostic is part of how the channel reaches its safety rating.

Seven ranges on one module

The module accepts +/-10V, +/-5V, 0...5V, 0...10V, 4...20 mA and 0...20 mA among seven configurable ranges, so one catalog number covers a load cell, a 4...20 mA transmitter and a +/-10V position sensor. Range selection is configuration, and it must match the safety configuration in the controller as well as the wiring.

Isolation and environment

50V continuous basic insulation from field to system, tested per UL 61010-1, with no isolation between channels. Field power is 19.2...28.8V DC at 65 mA Class 2, backplane draw is 110 mA at 5V DC, signalling ports must be shielded, and the temperature code is T4 with a 55 °C surrounding-air limit.

FAQ — 1734-IE4S

What safety rating does 1734-IE4S carry?

Up to SIL CL 3 per IEC 61508, IEC 61511 and IEC 62061, and PLe Cat. 4 per ISO 13849-1, for use with GuardLogix, Compact GuardLogix and SmartGuard controllers.

How many terminal bases does it need?

Two. Use 1734-TB or 1734-TBS, or one-piece 1734-TOP, 1734-TOPS, 1734-TOP3 or 1734-TOP3S. Do not use 1734-TB3 or 1734-TB3S, and set the keyswitch to 8 and 3.

What input ranges are available?

Seven configurable ranges including +/-10V, +/-5V, 0...5V, 0...10V, 4...20 mA and 0...20 mA, on four channels with individual sensor power outputs.

Can it power the sensors directly?

Yes. Each sensor output provides 24V DC at up to 150 mA at 55 deg C, individually current-limited and monitored, so a shorted lead is detected at the supply.

Is 1734-IE4S a drop-in replacement for 1734-IE2C?

No. It is a safety module for a safety task, needs two terminal bases and keyswitch 8/3, and has different field power requirements (19.2...28.8V DC, 65 mA Class 2).


Data sources. Technical values on this page come from Rockwell publication 1734-IN016-EN-P (POINT Guard I/O Safety Modules, catalog numbers 1734-IB8S, 1734-IE4S, 1734-OB8S, 1734-OBV2S and K variants) and 1734-UM013 (POINT Guard I/O Safety Modules User Manual). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1734 1734-IE4S: 4-point safety analog input

1734-IE4S is a 4-point safety analog input in the POINT I/O family. It mounts on a terminal base assembly that is ordered separately, connects to the POINTBus through the base, and presents its field wiring on the removable terminal block.

AttributeValue
Catalog number1734-IE4S
Module type4-point safety analog input
POINTBus current requirement75 mA
Module width12.1 mm (0.48 in.) standard, 24.1 mm (0.94 in.) for safety modules
Terminal baseOrdered separately: 1734-TB/TBS (8 terminal) or 1734-TB3/TB3S (12 terminal)
Module dimensions77.5 x 12.1 x 56.6 mm (3.05 x 0.48 x 2.23 in.), weight approx. 31-36 g
Filter settings50 Hz / 10 Hz / 5 Hz / 1 Hz
Step response to 63%approx. 25 ms / 72 ms / 125 ms / 450 ms
-3 dB corner frequency10.2 Hz / 4.75 Hz / 2.62 Hz / 0.68 Hz

POINTBus current is the budget that decides how many modules a slice can carry: most digital and analog modules draw 75 mA, the 1734-OW2 draws 80 mA, and 1734-IB4D draws 50 mA. The usable current of the adapter, plus that of any expansion power supply, divided by the per-module draw gives the maximum slice length, and that is a planning calculation rather than a rule of thumb.

Every POINT I/O module mounts in a terminal base that is ordered separately, and the number of field terminals on the base has to match the module: eight terminals for single-point-per-channel digital modules, twelve where the module needs a common or a shield return per channel group.

The filter setting is the engineering decision on this module: at 50 Hz the input follows a step in about 25 ms and rejects noise above roughly 10 Hz, while at 1 Hz the same step takes about 450 ms and the corner frequency drops to 0.68 Hz. A loop tuned at 50 Hz and then moved to 1 Hz for a noisy thermocouple will read stable and will also read late, and the delay belongs in the control loop timing rather than in a complaint about the sensor.

Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.

The system is rated for panel work rather than for a lab bench: modules plug onto bases that are already wired, the RTB stays on the wiring while the electronics come off, and the same base family accepts the next module of the same width. That is the reason a spare part for POINT I/O is usually an RTB or a base rather than a module, and why a maintenance stock built only from modules is incomplete.

Other catalog numbers and accessories for the same range are collected in the Allen-Bradley POINT I/O 1734 modules category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)